background image

2

Features

Input voltage

Inrush Current 

Input voltage range is single phase alternating 

The inrush current limiting circuit is built-in. 

current.  85

264Vac(47

63Hz).

The inrush current limiting circuit might released it 

We recommend that you do not use this power  

when the input re-turning on time is short, because 

supply unit outside of it's normal intended use in  

SCR is used for the inrush current limiting. So turn it 

order to avoid any damage or malfunctions.

on again enough after time.

The first inrush current and the second inrush

Output voltage setting

current flow because it adopts SCR method for the 

inrush current limiting circuit. 

You can Vout by using Output Voltage 

Adjustment Potentiometer that is next to the 

Over-current Protection(OCP)

connector (CN501).

You can increase output voltage by turning clockwise.
If you need decrease, you can turn it the other way. 

The over-current protection works and the output is 

Please use it within the following range when you 

intercepted when becoming 110% or more of the 

adjust the output voltage.

output current ratings.

/- 10% rated output voltage.

Remove the factor of the overload, and turn on the 

Do not use maximum output power.  

input again after a few minutes of cutting when 

 Do not exceed rated output current. 

resetting it. 

Please avoid operation in the over-current state 
for 10 seconds or more. 
It will cause damage or isolation failure. 

Over-Voltage Protection(OVP)

Remote Sensing

It detects when the output voltage exceeds by some 

reasons, and the output is intercepted at once.

When it works once, the over-voltage protection 
continues the output interception while the input is  

supplied.

Turn it on again after a few minutes after intercepting 

the input when resetting it. 

Note that the output voltage might be abnormal when 
you turn it on again. (In this case, the over voltage

 protection works again. )

Over Temperature Protection (OTP)

Note:

 We connected with wires between Pin#1 & Pin#2, 

Also Pin #3 & Pin#4 as a default settings when we ship 
from factory. This setting is for the customers who won't 
use remote sensing feature.  So, if you need to use this 
feature,  1) Please remove the existing wires   2) Use 
twisted cable for this feature to use shown as above. 

In order to reset this, please disconnect AC input, then 
confirm well cooling down the temperature inside the PSU 
after several minutes. Then please apply AC input.  Also 
please confirm the forced air convection would well enough 
to meet the air flow condition.  

2-3

2-2

Please use within 0.3V voltage drop range to adjust. 

2-1

2-7

It detects internal components temperature abnormally 
getting higher, then turn off the output. 

Once it detects and stops output, it stops supplying the 
output even AC input supplies. 

2-4

2-6

Then, please set up the output voltage range won't 
exceed voltage range we specify. 

Please twist the wires and install just besides in parallel 
with wires for load as shown below. 

2-5

  

  

Power  

Wire

Loa

Con

ne

ct

or

  

(C

N

501)

 

Отзывы: