background image

Temperature limitation of each components surface

If you need to calculate more in detail to choose suitable fan in your application, please see the information below. 

Please use each temperature range of the surface of each component.  

Please test under your worst/most severe condition.  We recommend you to use Type K thermocouple device.  
* Please make sure to attach firmly with adhesive when you measure these temp. 

Please make sure  1) No air flow condition 2) Measure its highest heat spot  
3) Operate PSU under all the temperature range and make sure it works stably.  

Measured components

*Refer to the following drawing to specify each component location. 

< Image from the top view >

MOS-FET

Diode

MOS-FET

Poly Switch

Thyristor

3-3

Max Temp (degree C)

100
110
115

P/N

Component name

C101

X Capacitor

Bridge Diode

Common mode choke

105

85

115
115
105

85

110
110
100

PC501

Photo Coupler

Poly Switch

D501

Secondary side Diode

115

T301

Transformer (Primary side coil)

T301

Transformer (Secondary side coil)

Q301

TH301

Q101
D102

SCR101

TH101

L101

D101

Q101 

D102 

SCR101 

D101 

PC501 

D501 

Q301 

C101 

L101 

T301 

(secondary coil ) 

TH101 

T301 

(primary coil)  

TH301 

Отзывы: