Swimming pool heat pump 

 

- 1 - 

 

To our customers   

 

 

 

 

 

 

 

 

Attention 

1.

 

Before  installing  the  heat  pump,  please  check  whether  the  local  power  supply  corresponds 

with the requirement of the heat pump. For details, please refer to the nameplate on the unit 

or the installation and operation instruction. 

2.

 

Please install the electrical protection devices according to local regulations. 

3.

 

Connecting  the  heat  pump  to  a  ground  wire  is  necessary,  in  order  to  prevent  electric  shock 

caused by an unexpected short circuit inside the unit. 

4.

 

In wire connection, the electrician can refer to the wiring diagram in this manual. Wiring tasks 

should  be  carried  out  by  qualified  electricians  only.  In  addition,  they  should  check  the  safety 

conditions of power utilization, for example, check if the cable capacity is adequate, and check 

if the power cable is damaged. 

5.

 

Do not insert any objects into the heat pump when running. It may touch the fan and damage 

it or lead to accidents (especially for the children). 

Do not use the unit without the grid in case it may lead to any accidents. 

6.

 

For  safety  reasons,  please  do  not  change  or  repair  unit  by  yourself.  If  it  is  necessary,  please 

contact local distributor for help. 

7.

 

If  there  is  something  wrong  with  the  unit,  contact  immediately  with  local  distributor  or  our 

factory. The unit can be reused only after check and solution by the technical staff. 

8.

 

Make sure that cut off the electric supply before maintaining the unit.   

9.

 

Please follow the instruction below when cleaning the unit. 

a.

 

Before cleaning, cut off the electric supply of the unit firstly to avoid injuries caused by fan 

in operation. 

b.

 

Do not rinse the unit by water because the rinsed unit may cause electric shock. 

Note!

 

Dear  customers,  thank  your  for  your  kind  support  to  our  products.  Please  read  this 

instruction carefully before the installation and application of this product

The precautions 

listed below are all-important for safety. Please follow the instructions strictly. 

Содержание DSP?45HCA

Страница 1: ...Air Source Swimming Pool Heat Pump USER MANUAL DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Страница 2: ...p when running It may touch the fan and damage it or lead to accidents especially for the children Do not use the unit without the grid in case it may lead to any accidents 6 For safety reasons please...

Страница 3: ...Swimming pool heat pump 2 Content Product brief instruction 3 Technical data 4 Unit dimension 6 Installation 8 Electric connection 13 Controller operation instruction 16 Maintenance Troubleshooting 22...

Страница 4: ...l water Your existing water pump circulates the water through the heat pumps heater usually next to the pool equipment and the water warms up This pool heat pump is also of cooling function User can c...

Страница 5: ...220 240 1 50 Setting Temp Range 15 45 Running Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 3 4 4 4 5 4 5 Refrigerant R410A Unit Dimension W H D mm...

Страница 6: ...Temp Range 5 43 Water Inlet Outlet Dimension 50 8mm Water Heat Exchanger Titanium Water Flow m3 h 7 5 8 5 Refrigerant R410A Unit Dimension W H D mm 820X720X1055 Net Weight KG 119 119 133 133 148 Disp...

Страница 7: ...ol heat pump 6 UNIT DIMENSIONS Horizontal models Model A mm B mm C mm D mm E mm DSP 45 HCA 510 306 266 276 410 DSP 65 85 HCA 552 995 284 344 680 DSP 100 HCA 617 1118 350 290 660 DSP 120 HCA 650 1140 4...

Страница 8: ...Swimming pool heat pump 7 Vertical models DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...

Страница 9: ...installed on the floor its undercarriage should be heightened to avoid ingression of accumulated water in rainy season In snowy areas it is important to prevent accumulated snow from blocking up the a...

Страница 10: ...led anywhere outdoors providing minimum distance requirements are met with respect to other objects For indoor pools please consult your installer Attention Do not place the unit in an enclosed area w...

Страница 11: ...hould be avoided as much as possible as machine falling down may result in severe accident Distance from the pool Normally the pool heat pump is installed within a 7 5 meter radius of the swimming poo...

Страница 12: ...be lower than the unit standard value please refer to the nameplate 2 The insulation of water pipe should be done well to prevent energy loss 3 A suitable draining valve should be installed in the bot...

Страница 13: ...Swimming pool heat pump 12 Project Installation sketch map...

Страница 14: ...e neutral ground via a distribution board with fuses If an insulation test is to be carried out in the building please make sure to disconnect the heat pump To avoid the possibility of false action ca...

Страница 15: ...Swimming pool heat pump 14 Circuit diagram Model DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA...

Страница 16: ...Swimming pool heat pump 15 Model DSP 180HCA 3 DSP 230HCA 3 DSP 260HCA 3...

Страница 17: ...ON or OFF at any state At the ON state press the key into OFF state it shows Clock Working mode and Timer status At the OFF state press the key to start unit it shows Water inlet temp Working mode and...

Страница 18: ...quiry interface of parameter and state it exits inquiry interface to enter into main interface if there is no any operation for 8 seconds 1 3 System parameter setting 1 3 1 At inquiry interface if it...

Страница 19: ...election parameter 0 Only cold 1 Heat pump 2 E heater 3 Only heat 1 Adjustable 09 Water pump working Mode 0 Normal 1 Special 0 Adjustable 10 Automatic return water temp setting value 8 60 40 Adjustabl...

Страница 20: ...is only valid remote controller Parameter table LCD or LED Parameter Meaning Range Default Remark 00 or 0 Cooling return water temp setting value 8 28 12 Adjustable 01 or 1 Heating return water temp...

Страница 21: ...mp difference protection PP 06 or PP 6 Bright Cooling anti freezing protection PP 07 or PP 7 Bright Winter first grade anti freezing protection PP 07 or PP 7 Extinguish Winter second grade anti freezi...

Страница 22: ...does not occur Discharge the water at the bottom of water pump if the unit will not be used for an extended period of time Check the unit thoroughly and fill the system with water fully before using...

Страница 23: ...ire 4 Replace it with new high pressure switch 5 It is done by professionals EE 02 or EE 2 Low pressure protection 1 Check the connecting wire 2 Check if low pressure switch is broken 3 Check if lack...

Страница 24: ...DAISHIBA Heating Refrigeration Equipment Co Ltd Web www daishiba com cn Tel 86 757 85213698 Fax 86 757 85213699 Email jenny daishiba com cn Add No 2 Chuangye Nan Road Songxia Industrial Park Songgang...

Отзывы: