Swimming pool heat pump
- 18 -
Parameter table (1100-3502 A
、
、
、
、
B type Swimming Pool Heat Pump LCD Controller)
Parameter
Meaning
Range
Default
Remark
00
Cooling return water temp
setting value
8~28
℃
12
℃
Adjustable
01
Heating return water temp
setting value
15~40
℃
40
℃
Adjustable
02
Heating Defrosting period
30~90Min
40Min
Adjustable
03
Enter Heating Defrosting
Temperature spots
-30~0
℃
-7
℃
Adjustable
04
Exit Heating Defrosting
Temperature condition
2~30
℃
13
℃
Adjustable
05
Exit Heating Defrosting Time
condition
1-12Min
8Min
Adjustable
06
System quantity
1/2
2
Invalid
07
Power failure protection
0(No) /1(Yes)
0
Adjustable
08
Model Selection parameter
0(Only cold) /1(Heat pump)
/2(E-heater) /3(Only heat)
1
Adjustable
09
Water pump working Mode
0(Normal) /1(Special)
0
Adjustable
10
Automatic return water temp
setting value
8~60
℃
40
℃
Adjustable
System state (1100-3502 A
、
、
、
、
B type Swimming Pool Heat Pump LCD Controller)
Code
Meaning
Display range
Remark
IN
Water inlet
temp
-9~90
℃
Measured value
OUT
Water outlet
temp
-9~90
℃
Measured value
P1
System pipe
temp
-9~90
℃
Measured value
P2
Reservation
-9~90
℃
Reservation
ROOM
Ambient temp
-9~90
℃
Measured value
System fault (1100-3502 A
、
、
、
、
B type Swimming Pool Heat Pump LCD Controller)
Protection / Fault
Remote
controller
Host unit running /
Fault indicator light
Standby
Extinguish
Normal starting up
Bright
Water inlet temp. sensor fault
PP 01
☆●
(1 Flash and 1 Extinguish)
Water outlet temp. sensor fault
PP 02
☆☆●
(2 Flash and 1 Extinguish)
Содержание DSP?45HCA
Страница 8: ...Swimming pool heat pump 7 Vertical models DSP 180HCA DSP 180HCA 3 DSP 230HCA DSP 230HCA 3 DSP 260HCA 3...
Страница 13: ...Swimming pool heat pump 12 Project Installation sketch map...
Страница 15: ...Swimming pool heat pump 14 Circuit diagram Model DSP 45HCA DSP 65HCA DSP 85HCA DSP 100HCA DSP 120HCA...
Страница 16: ...Swimming pool heat pump 15 Model DSP 180HCA 3 DSP 230HCA 3 DSP 260HCA 3...