background image

2

Lumination

®

 (LRX - Series) 

Installation Guide

Kit vs Fixture

LRXR EMBB Fixture

LRXR EMBB Frame Kit

LRXS EMBB Fixture

LRXS EMBB Frame Kit

SAP Description

SAP Description

SAP Description

SAP Description

LRXR410ABBCCEL

LRXEMBBKIT07HE

LRXS410ABBCCEL

LRXEMBBKIT07HE

LRXR610ABBCCEL

FRAME6REL07

LRXS610ABBCCEL

FRAME6SEL07

LRXR618ABBCCEL

FRAME6REL10

LRXS618ABBCCEL

FRAME6SEL10

LRXR618ABBCCEL

FRAME6REL10

LRXS618ABBCCEL

FRAME6SEL10

LRXR810ABBCCEL

FRAME8REL07

LRXS810ABBCCEL

FRAME8SEL07

LRXR818ABBCCEL

FRAME8REL10

LRXS818ABBCCEL

FRAME8SEL10

LRXR830ABBCCEL

FRAME8REL10

LRXS830ABBCCEL

FRAME8SEL10

LRXR840ABBCCEL

LRXS840ABBCCEL

Nomenclature for

 

LRX Series: 

I

 - “A” Denotes color rendering index (CRI)

  

8

 - 80

  

9

 - 90

II

 - “BB” Denotes correlated color temperature (CCT)

  

27

 - 2700K

 

30

 - 3000K

 35

 - 3500K

 40

 - 4000K

 50

 - 5000K

Save These Instructions

Use only in the manner intended by the manufacturer. If you 

have any questions, contact the manufacturer.

LRXREL Fixture

Thickness of Ceiling

LRXSEL Fixture

Thickness of Ceiling

SAP Description

Max.(mm)

SAP Description

Max.(mm)

LRXR410ABBCCEL

15

LRXS410ABBCCEL

15

LRXR610ABBCCEL

LRXS610ABBCCEL

LRXR618ABBCCEL

LRXS618ABBCCEL

LRXR618ABBCCEL

20

LRXS618ABBCCEL

20

LRXR810ABBCCEL

LRXS810ABBCCEL

LRXR818ABBCCEL

LRXS818ABBCCEL

LRXR830ABBCCEL

LRXS830ABBCCEL

LRXR840ABBCCEL

LRXS840ABBCCEL

III

 - “CC” Denotes dimming type

 MD

 - 0-10V Dimming

 

PH

 - Phase cut Dimming

• LRXEMBBKIT07HE shall be mounted Max. 20.11 ft ( 6.12 m)

• LRXEMBBKIT07 shall be mounted Max. 22.71ft (6.92m)

• LRXEMBBKIT10 shall be mounted Max. 25.99ft (7.92m)

Thickness of ceiling is listed below:

CAUTION / ATTENTION

• 

Fixture may fall down if not installed properly, follow 

installation instructions.

•  Wear safety glasses and proper aid during installation and 

maintenance. 

• 

Use only UL certified copper wire, wire connectors, 

minimum 18AWG, minimum rated 75°C.

• 

Porter des lunettes de sécurité et utiliser des outils adéquats durant l’installation 

et la maintenance.

• 

Utiliser seulement du câblage de cuivre classé 75°C et approuvé par UL pour les 

connections d’entrées et de sorties.

• 

Utiliser des conducteurs de grosseur 18AWG minimum ou de grosseur 14AWG 

dans le cas de montage en rangée continue.

NOTE:

 LRXEMBBKIT07HE, LRXEMBBKIT07 and LRXEMBBKIT10 are suitable for wet locations and are intended for covered ceiling installation only. The retrofit kit is accepted as a component of a luminaire

where the suitability of the combination shall be determined by UL or authorities having jurisdiction.
Wear work gloves to prevent dirt and oil from being transferred to the luminaire.

Отзывы: