4
Lumination
®
(LRX - Series)
Installation Guide
Frame Installation
2
Ensure that the power to the unit is turned off.
Use proper lockout and tagout procedures.
3
Remove existing downlight fixture. Leave wiring in Junction
box. Verify that the AC supply line is provided with a
ground wire connected to the luminaire.
Connect AC and
dimming conduit
Junction
LRXEMBB IT07
LXREMBBKIT10
box
Dimming (optional)
AC line
Grounding
Dimming (+)
Unswitched Power (L1)
Common (N)
Switched Power (L2)
Dimming (–)
Black
White
Red
Yellow-Green
Violet
Gray
4
Connect the conduit for the fixture AC and dimming leads to the junction box. Verify that the AC supply line and dimming leads are
connected properly (see wiring diagram).
Note:
For phase cut dimming product, dimming leads can be disconnected
• If dimming leads will not be utilized, please do not remove the wire connectors.
• Dimming compatibility for both 0-10V and phase cut, please refer to Current’s website: www.gecurrent.com/dimming.
Connect AC and
dimming conduit
Junction
LRXEMBB IT07
LXREMBBKIT10
box
Dimming (optional)
AC line
Grounding
Dimming (+)
Unswitched Power (L1)
Common (N)
Switched Power (L2)
Dimming (–)
Black
White
Red
Yellow-Green
Violet
Gray
“L” Bridge
Secure
battery
5
Connect male and female ends of the battery unit
connector. Then the battery will discharge. Please
refer to the picture shown above.
“L” Bridge
Secure
battery
6
Attach LRXEMBBKIT07HE, LRXEMBBKIT07 or
LRXEMBBKIT10 to existing frame with “L” bridge and
secure IOTA battery to the ceiling.