DTP10-L hardware user
’s manual
DAINCUBE Corp.
30 / 42
8.3. Wiring
8.3.1. Emergency Switch wiring
The emergency stop
switch used on the DTP10-L
features two circuits.
The contacts are normally closed.
DTP10
(DTP-CU-26R)
3
4
5
6
Emergency 1+
Emergency 1-
Emergency 2+
Emergency 2-
NC
1
NC
2
NC
1
NC
2
NC
1
NC
2
NC
1
NC
2
NC
1
NC
2
NC
1
NC
2
Safety
Control
Block
n
S1
S2
26pin Circular
receptacle
Add Emergency
Switch
[Figure 8-5]
Emergency Switch wiring example
As shown in the figure, the wiring in series with the safety control block.
8.3.2. Enabling Switch wiring
The enable
switch used on the DTP10-L
features two circuits.
The enabling switch is connected to a dry contact.
(DTP-CU-26R)
DTP10
SWEN1+
C1
NO1
NC1
NC2
C2
NO2
SWEN1-
SWEN2-
SWEN2+
1
2
7
8
Enable
Enable switch 1-
Enable switch 2+
Enable switch 2-
Safety
Control
Block
E1
E2
26pin Circular
receptacle
[Figure 8-6] E
nabling Switch wiring example
8.3.3. Select Switch wiring
DTP10
(DTP-CU-26R)
SELCOM2-
SELCOM1-
NC
1
NC
2
NO
1
NO
2
NO
1
NO
2
9
10
11
17
Select
Select
Select switch1-
Select switch2-
Input Module
DC24V
Common
Input 1
Input 1
[Figure 8-7] Select
Switch wiring example