background image

31

Perform the Blood Glucose Test

To enter Memory Mode

With the meter off, press any key to switch the meter on.
Under Standby Mode, press MODE button to enter Memory Mode.

1

Memory Recall

DailyChek

®

 Premium Blood Glucose Meter stores latest 500 test 

results with time and date in the memory automatically. It also provides 

7/ 14/ 28/ 60/ 90 day

 average of your blood glucose test results. 

NOTE

It is recommended to set time and date correctly before testing.
The average of last 7/14//28/60/90 day results may not be as expected if 
the date setting of records is not precisely set.
The 7-day average is calculated from the test results obtained during the 
last 7 days counting from the date of last record. And it’s all the same to 
14-, 28-, 60-, and 90- day average.
The results of “LO” or “HI” will not be calculated as the average of the last 
7/14//28/60/90 day results.
“Ketone” warning won’t appear under 7/14/28/60/90 day average mode.
If the Meal Comment Function is set on, the      or      symbol will appear 
on the screen while recalling the readings in the memory.

All the results in memory can be recalled by following steps:

NOTE

Press SET button for 3 seconds to leave Memory Mode and return to 
Standby Mode.

Содержание HL568AA

Страница 1: ...User s Manual Premium Self Monitoring Blood Glucose System Premium Blood Glucose Meter...

Страница 2: ......

Страница 3: ...g A warranty registration card is included with your system Please forward your warranty card immediately to HEALTH LIFE CO LTD If you have any concerns please call our HEALTH LIFE CO LTD office or au...

Страница 4: ...ake them safe Do not block the openings of DailyChek Premium Blood Glucose Meters keep the openings free from dust hair stuff etc If you feel you are suffering from severe dehydration consult the heal...

Страница 5: ...mber Use by in vitro diagnostic medical device AAA 1 5 V alkaline battery x 2 Do not reuse Temperature limitation Manufacturer Consult instructions for use Catalog number Serial number Biological Risk...

Страница 6: ...em Key Features Get Ready for Testing Quality Control of the System Perform the Blood Glucose Test Use the Data Link Function Maintain Your Meter System Specifications Display Messages and Troubleshoo...

Страница 7: ...mmol L 240 mg dL mean high blood glucose hyperglycemia If you get results below 3 9 mmol L 70 mg dL or above 13 3 mmol L 240 mg dL and do not have symptoms repeat the test If you have symptoms or con...

Страница 8: ...e design DailyChek Premium SMBG Systems by using the latest biosensor technology It measures the glucose levels of the blood specimen by using a disposable dry reagent strip which can produce an elect...

Страница 9: ...et Complete instructions 1 User s Manual 2 Quick Reference Guide 3 DailyChek Log Book 4 Warranty Card NOTE DailyChek Blood Glucose Test Strips and DailyChek Glucose Control Solution High and Low Level...

Страница 10: ...ption DailyChek Premium Blood Glucose Meter Display Screen MODE Button Shows blood glucose results messages and glucose results stored in memory Press to enter the different setting mode which you wan...

Страница 11: ...ymbol Indicates it s ready to apply the blood sample Decimal Point Appears in unit only set to mmol L Ketone Warning mmol L mg dL Temperature Symbol Indicates the ambient temperature is outside the op...

Страница 12: ...irritation NOTE DailyChek Blood Glucose Test Strips are used with DailyChek Premium Blood Glucose Meter only Do not touch the strip with a wet hand Do not use strips beyond the expiration date printed...

Страница 13: ...used with sterile lancet to obtain the blood for the testing Cap Depth Settings Indicator Lancet Ejector Release Button Cocking Handle Lancets It is used with lancing device to obtain the blood for th...

Страница 14: ...ws users to add a food comment to the test result You may select the AC symbol if you perform the test before a meal or select the PC symbol if you perform the test after a meal It benefits you to man...

Страница 15: ...etting for the Meal Comment Function is AC after meal testing where the AC symbol will appear with the test result If the AC comment is selected each test result will appear with the AC symbol Yet you...

Страница 16: ...umulate in the blood and are excreted in the urine Ketone Warning When your test result is equal to or higher than 13 3mmol L 240 mg dL Ketone symbol appears on the screen It indicates there is a poss...

Страница 17: ...old batteries To save the power please take out the batteries if you do not use the meter for a long period approx 2 months or more To avoid inaccurate results caused by electromagnetic interference...

Страница 18: ...ng Mode If you power the meter on by loading batteries please skip this step The number of year is flashing Press SET button to scroll forward and select the correct number of year then press MODE but...

Страница 19: ...ng Mode and follow the above step 6 to complete the code setting A Press SET button to select the correct number and MODE button to confirm the selection Then single digit starts flashing B Repeat the...

Страница 20: ...strip correctly Fig 2 Inserting the strip with the wrong end will not turn on the meter Fig 3 Inserting the strip with up side down will not turn on the meter Fig 4 Inserting the strip with the wrong...

Страница 21: ...en a new vial of test strips If you drop your meter If your result does not agree with the way you feel or result is lower or higher than expected Whenever you want to check for performance of the tes...

Страница 22: ...ip vial you can go to next step If not refer to section Code Setting to set the code number Shake the glucose control solution well before squeezing Discard the first droplet and squeeze the second on...

Страница 23: ...the expected range please check the following Are the control solutions or test strips within the expiration date Has the control solution been contaminated Is the code number correct Did you follow...

Страница 24: ...nd be sure to put it back on to the lancet before you discard the lancet after the test Clean the outside of the lancing device by using alcohol or soap and water If the meter shows or symbol it means...

Страница 25: ...6 Replace and screw the cap snugly Choose the depth of lancing Select 1 2 for soft o r thin skin 3 4 for average skin 5 6 for thick or calloused skin 4 Pull the cocking handle back until it clicks 5 T...

Страница 26: ...de Setting to set the code number 8 Insert a new test strip make sure it goes all the way in The meter will turn on automatically when it detects the test strip 7 To avoid body fluid contamination wip...

Страница 27: ...t on the top of the test strip 12 This strip has the correct amount of blood Make sure that the blood fills the reaction zone completely If too little blood enters the reaction zone an underfill an er...

Страница 28: ...y from the strip After 5 seconds the device will beep again and display OK indicating the testing is completed 13 mmol L If the Meal Comment Function is activated on the test result will appear along...

Страница 29: ...ip Or the meter will automatically shut down after 2 minutes if without any operation 17 Unscrew the cap of the lancing device and re cap the lancet then push the lancet ejector forward to remove the...

Страница 30: ...1 LO and HI Readings Important information HI reading with symptoms If you feel symptoms such as fatigue thirst excess urination or blurry vision Then follow your doctor s recommendation to treat hyp...

Страница 31: ...ults may not be as expected if the date setting of records is not precisely set The 7 day average is calculated from the test results obtained during the last 7 days counting from the date of last rec...

Страница 32: ...tton the 14 28 60 90 day average record will appear in order You can then review the last 500 individual test result in memory 2 NOTE In the above figure the numeral 07d indicates the average value is...

Страница 33: ...After the 90 day average the latest reading appears with the memory sequence number then the date and time instead Press MODE button to view the next most recent reading Then press MODE button each ti...

Страница 34: ...delete all records Press SET and MODE buttons simultaneously for 3 seconds the screen will show dA for confirmation Press SET button again for 3 seconds to delete all records Or press MODE button to...

Страница 35: ...Compatible computer with USB port CPU at least Pentium CD ROM drive CD ROM 4x or faster HDD 100MB or more space RAM 512MB or more Resolution of monitor 1024 x 768 Software requirements Compatible for...

Страница 36: ...k Glucose Data Transmission Software User s Manual to transfer the test results in the meter memory to your computer Use the Data Link Function When USb appears on display it indicates that the meter...

Страница 37: ...ther liquid into the test strip slot Never immerse the meter in water or any other liquid solution Display Check When the meter is off press any key to switch it on The display should look exactly lik...

Страница 38: ...rature between 10 40 C 50 104 f Out of this range the system will not work Extreme humidity may affect the results A relative humidity greater than 80 may cause incorrect results Hematocrit The test r...

Страница 39: ...rs Package with the lancet or strips Blood Volume 1 L Sample Type Capillary whole blood Hematocrit Hct 30 55 Power AAA 1 5V alkaline battery x 2 Battery Life At least 1000 measurements Display Dimensi...

Страница 40: ...i p Follow instructions in Perform the Glucose Blood Test section Display messages What it means Troubleshooting M a k e s u r e t h e operation condition is within 10 40 C and R H 80 Repeat the test...

Страница 41: ...e a or reading that m e a n s t h e t e s t e n v i r o n m e n t a l condition is out of desired range and the test will be terminated Repeat the test after replacing the battery See Get Ready for Te...

Страница 42: ...tely DailyChek Glucose Control Solution Sold Separately HEALTH LIFE CO LTD 9F No 186 Jian Yi Road Chung Ho City 235 Taipei Taiwan Tel 886 2 8227 1300 Fax 886 2 8227 1301 E mail public hlmt com tw http...

Страница 43: ...zhou China 215131 Tel 86 512 65799308 www sterilance com Meets the requirement of MDD 93 42 EEC Lancets Meets the regairement of MDD 93 42 EEC SteriLance Medical Suzhou Inc No 68 Litanghe Road Xiangch...

Страница 44: ...ect in materials or workmanship HEALTH LIFE CO SERVICE will repair the meter or replace it with a new DailyChek Premium Blood Glucose Meter or equivalent product free of charge The warranty of the rep...

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...P N 323101718 VER 001 20110518...

Отзывы: