
2
English
1. Introduction
1.1. General information
This installation manual concerns the VRV RXYQ-A series, full
inverter driven, heat pump system.
6
7
6
6
3
3
3
5
4
2
1
8
1 Outdoor unit
2 Refrigerant piping
3 VRV indoor unit
4 Branch Provider unit (required to connect Mini-split indoor
units)
5 Mini-split indoor units
6 User interface (dedicated depending on indoor unit type)
7 User interface (wireless, dedicated depending on indoor unit
type)
8 Cool/Heat selector
INFORMATION
Not all combinations of indoor units are allowed. For guidance, see
1.2. Combinations and options.
1.2. Combinations and options
The VRV RXYQ-A series heat pump system can be combined with
several types of indoor units and is intended for R410A use only.
For an overview which units are available you can consult the product
catalogue for VRV RXYQ-A series.
NOTE
To be sure your system setup (outdoor unit + indoor unit(s)) will work,
you have to consult the latest technical engineering data for VRV
RXYQ-A series.
An overview is given indicating the allowed combinations of indoor
units and outdoor units. Not all combinations are allowed. They are
subject to rules (combination between outdoor-indoor, single outdoor
unit use, multiple outdoor unit use, combinations between indoor
units, etc.) mentioned in the technical engineering data.
1.2.1. Indoor unit combinations
In general following type of indoor units can be connected to a VRV
RXYQ-A series. The list is non-exhaustive and depends on both out-
door unit model and indoor unit model combinations.
• VRV indoor units.
• Mini-split indoor units.
• AHU (air to air applications): AHU Integration kit is required. See
latest Engineering Data Book for more details .
1.2.2. Outdoor units combinations
Combination for RXYQ-A units are as indicated in tables right, where
RXYQ 264-480 consists of multiple RXYQ 120-240 single modules as
indicated.
72
96 120 144 168 192 216 240
RXYQ72AATJ*/AAYD*
1
RXYQ96AATJ*/AAYD*
1
RXYQ120AATJ*/AAYD*
1
RXYQ144AATJ*/AAYD*
1
RXYQ168AATJ*/AAYD*
1
RXYQ192AATJ*/AAYD*
1
RXYQ216AATJ*/AAYD*
1
RXYQ240AATJ*/AAYD*
1
RXYQ264AATJ*/AAYD*
1
1
RXYQ288AATJ*/AAYD*
2
RXYQ312AATJ*/AAYD*
1
1
RXYQ336AATJ*/AAYD*
2
RXYQ360AATJ*/AAYD*
1
1
RXYQ384AATJ*/AAYD*
2
RXYQ408AATJ*/AAYD*
1
1
RXYQ432AATJ*/AAYD*
2
RXYQ456AATJ*/AAYD*
1
1
RXYQ480AATJ*/AAYD*
2
To install the outdoor unit, the following accessory parts are also required.
1
Refrigerant branch kit
Description
Model name
REFNET header
KHRP26M22H9
KHRP26M22HA
KHRP26M33H9
KHRP26M33HA
KHRP26M72H9
KHRP26M72HA
KHRP26M73HU9
KHRP26M73HUA
REFNET joint
KHRP26A22T9
KHRP26A22TA
KHRP26A33T9
KHRP26A33TA
KHRP26M72TU9
KHRP26M72TUA
KHRP26M73TU9
KHRP26M73TUA
For the selection of the optimal branch kit, refer to 7.4. Selection of
refrigerant branch kits on page 12.
2
Outdoor unit multi connection piping kit
- BHFP22P100U, BHFP22P100UA
3
Reducer piping kit
- KHFP26P100UA
4
In order to control the cooling or heating operation from a central
location, the following option can be connected:
- Cool/Heat selector: KRC19-26A
-
With optional fixing box for the switch: KJB111A
- Centralized control devices (e.g., intelligent Touch Manager)
5
To instruct specific operation with an external input coming from a
central control the external control adaptor (DTA104A62) can be
used. Instructions (group or individual) can be instructed for low
noise operation and power consumption limitation operation.
6
For RXYQ-A units it is also possible to make several commission-
ing field settings through a personal computer interface. For this
operation, an optional cable is required which is a dedicated cable
to communicate with the outdoor unit. The software for the user in-
terface program can be obtained from your local Daikin sales office.
INFORMATION
Refer to the technical engineering data for the latest option names.
01_EN_Main_VRV6_HP_IM.indd 2
01_EN_Main_VRV6_HP_IM.indd 2
2022/11/17 16:06:56
2022/11/17 16:06:56