Installation Manual
EDUS341411-N
14
Installation of Outdoor Units
3P362438-1B
4
3P362438-1B English
3.2.
6GEJPKECNCPF'NGEVTKECNURGEKƂECVKQPU
4GHGTVQVJG'PIKPGGTKPI&CVC$QQMHQTVJGEQORNGVGNKUVQHURGEKƂEC
-
tions.
3.3. Main
components
For main components and function of the main components, refer to
VJG'PIKPGGTKPI&CVC$QQM
4. Selecting an installation location
WARNING
Be sure to provide for adequate measures in order to prevent that the
unit is used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunc-
VKQPUUOQMGQTƂTG2NGCUGKPUVTWEVVJGEWUVQOGTVQMGGRVJGCTGC
around the unit clean and clear.
In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.
CAUTION
Appliance not accessible to the general public, install it in a secured
area, protected from easy access.
This unit, both indoor and outdoor, is suitable for installation in a com-
mercial and light industrial environment.
4.1. General precautions on installation
Select an installation site that meets the following requirements:
r
The foundation must be strong enough to support the weight of the
unit.
r +PUVCNNCVKQPNQECVKQPKUƃCVVQRTGXGPVXKDTCVKQPUCPFPQKUGIGPGTCVKQP
CPFVQJCXGUWHƂEKGPVUVCDKNKV[
r
The space around the unit is adequate for maintenance and servic-
KPITGHGTVQ5GTXKEGURCEGQPRCIG|
r 6JGURCEGCTQWPFVJGWPKVCNNQYUHQTUWHƂEKGPVCKTEKTEWNCVKQP
r 6JGTGKUPQFCPIGTQHƂTGFWGVQNGCMCIGQHKPƃCOOCDNGICU
r 6JGGSWKROGPVKUPQVKPVGPFGFHQTWUGKPCRQVGPVKCNN[GZRNQUKXG
atmosphere.
r
Select the location of the unit in such a way that the sound generat-
ed by the unit does not disturb anyone, and the location is selected
according the applicable legislation.
r
All piping lengths and distances have been taken into consideration
TGHGTVQ5[UVGORKRKPINGPIVJNKOKVCVKQPUQPRCIG|
r
Take care that in the event of a water leak, water cannot cause any
damage to the installation space and surroundings.
r
When installing the unit in a small room, take measures in order to
MGGRVJGTGHTKIGTCPVEQPEGPVTCVKQPHTQOGZEGGFKPICNNQYCDNGUCHGV[
limits in the event of a refrigerant leak, refer to 18. Caution for refrig-
GTCPVNGCMUQPRCIG|
CAUTION
'ZEGUUKXGTGHTKIGTCPVEQPEGPVTCVKQPUKPCENQUGFTQQOECPNGCFVQ
QZ[IGPFGƂEKGPE[
NOTE
The equipment described in this manual may cause electronic noise
generated from radio-frequency energy. The equipment complies
VQURGEKƂECVKQPUVJCVCTGFGUKIPGFVQRTQXKFGTGCUQPCDNGRTQVGEVKQP
against such interference. However, there is no guarantee that inter-
ference will not occur in a particular installation.
It is therefore recommended to install the equipment and electric wires
keeping proper distances away from stereo equipment, personal
computers, etc
3
1
4
2
5
2
A
B
B
A
A
A
B
1
Indoor unit
2
Branch switch, overcurrent breaker
3
Remote controller
4
Cool/Heat selector
5
Personal computer or radio
A
t
60 in. (1500 mm)
B
t
40 in. (1000 mm)
An inverter air conditioner may cause electronic noise generated from
#/DTQCFECUVKPI'ZCOKPGYJGTGVQKPUVCNNVJGOCKPCKTEQPFKVKQPGT
and electric wires, keeping proper distances away from stereo equip-
ment, personal computers, etc.
Particularly for locations with weak reception, ensure there is a dis-
tance of at least 10 ft. (3 m) for indoor remote controllers, place power
wiring and transmission wiring in conduits, and ground the conduits.
r 6JGTGHTKIGTCPV4#KVUGNHKUPQPVQZKEPQPƃCOOCDNGCPFKUUCHG
+HVJGTGHTKIGTCPVUJQWNFNGCMJQYGXGTKVUEQPEGPVTCVKQPOC[GZEGGF
the allowable limit depending on room size. Due to this, it could be
necessary to take measures against leakage. Refer to 18. Caution
HQTTGHTKIGTCPVNGCMUQPRCIG|
r
Do not install in the following locations:
- Locations where sulfurous acids and other corrosive gases may
be present in the atmosphere. Copper piping and soldered joints
may corrode, causing refrigerant to leak.
- Locations where a mineral oil mist, spray or vapor may be pres-
ent in the atmosphere. Plastic parts may deteriorate and fall off or
cause water leakage.
- Locations where equipment that produces electromagnetic
waves is found. The electromagnetic waves may cause the con-
trol system to malfunction, preventing normal operation.
-
.QECVKQPUYJGTGƃCOOCDNGICUGUOC[NGCMYJGTGVJKPPGT
gasoline and other volatile substances are handled, or where
carbon dust and other incendiary substances are found in the
atmosphere. Leaked gas may accumulate around the unit, caus-
KPICPGZRNQUKQP
r
When installing, take strong winds, hurricanes or earthquakes into
account, improper installation may result in the unit turning over.
4.2. Weather related precautions
r
Select a place where the rain can be avoided as much as possible.
r
Be sure that the air inlet of the unit is not positioned towards the
main wind direction. Frontal wind will disturb the operation of the
unit. If necessary, use a screen to block the wind.
r 'PUWTGVJCVYCVGTECPPQVECWUGCP[FCOCIGVQVJGNQECVKQPD[
adding water drains to the foundation and prevent water traps in the
construction.
r
Do not install the unit in areas where the air contains high levels of
salt such as that near the ocean.
Содержание VRV IV RXYQ TTJU Series
Страница 1: ...EDUS341411 N Installation...
Страница 61: ...REFNET Joint and Header EDUS341411 N 62 Installation of Outdoor Units KHRP26M72TU KHRP26M73TU 3P161697D...
Страница 62: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 63 3P161697D...
Страница 66: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 67 C 3P113151C 7 8 1 1 1 8...
Страница 67: ...REFNET Joint and Header EDUS341411 N 68 Installation of Outdoor Units KHRP26M73HU 3P185500...
Страница 68: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 69 3P185500...
Страница 70: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 71 1P218719...
Страница 71: ...REFNET Joint and Header EDUS341411 N 72 Installation of Outdoor Units 1P218719...
Страница 72: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 73 1P218720...
Страница 73: ...REFNET Joint and Header EDUS341411 N 74 Installation of Outdoor Units 1P218720...
Страница 75: ...REFNET Joint and Header EDUS341411 N 76 Installation of Outdoor Units 1P280278A...
Страница 76: ...EDUS341411 N REFNET Joint and Header Installation of Outdoor Units 77 1P280278A...
Страница 77: ...REFNET Joint and Header EDUS341411 N 78 Installation of Outdoor Units 1P280279...
Страница 78: ...EDUS341411 N Caution Label Installation of Outdoor Units 79 6 Caution Label 6 1 RXYQ72TYDN RXYQ72TTJU 2P361359C...
Страница 79: ...Caution Label EDUS341411 N 80 Installation of Outdoor Units 2P361359C...
Страница 80: ...EDUS341411 N Caution Label Installation of Outdoor Units 81 3P357947A...
Страница 81: ...Caution Label EDUS341411 N 82 Installation of Outdoor Units 3P357947A...
Страница 82: ...EDUS341411 N Caution Label Installation of Outdoor Units 83 6 2 RXYQ96 168TYDN RXYQ96 168TTJU 3P361373...
Страница 83: ...Caution Label EDUS341411 N 84 Installation of Outdoor Units 1P361833B...
Страница 84: ...EDUS341411 N Caution Label Installation of Outdoor Units 85 1P361833B...
Страница 85: ...Caution Label EDUS341411 N 86 Installation of Outdoor Units 1P361833B...
Страница 86: ...EDUS341411 N Caution Label Installation of Outdoor Units 87 1P361833B...
Страница 87: ...Caution Label EDUS341411 N 88 Installation of Outdoor Units 1P361833B...
Страница 88: ...EDUS341411 N Caution Label Installation of Outdoor Units 89 1P361833B...
Страница 89: ...Caution Label EDUS341411 N 90 Installation of Outdoor Units 3P357946A...
Страница 90: ...EDUS341411 N Caution Label Installation of Outdoor Units 91 3P357946A...