TERMI N AL OF M1C, M2C
W
U
V
LAYOUT OF M1C, M2C, M1F
EL. COMP O. B OX
X1A
X2A
L
a
m
p
ira
n
R
E
D
W
H
T
B
LK
R
E
D
W
H
T
B
LK
R
E
D
K1
R
K2
R
K3
R
K5
R
K1
1R
CATU DAYA
Y1: 380-415V 3N~50Hz
L1 L2 L3 N
A2P
Z1C
N=2
C1
X1A
A1P
RED X1A F1U
BLU
X18A
PS
t˚ R1T
X3A
X4A X5A
X7A
F1U
HA P
CA TA TA N)4.
BLK
F2U Q1RP
S1PH P
<
X2A
X7A
X8A
X11A X12A
X13A
X15A
HAP
ON DS1
X31A
X32A
S1NPL
X1M L1 L2 L3 N
A9P
1 3 2 4
X9A
S2PH P
<
X3A
Y1S Y2S
E1HC E2HC
Y10S
Y4S
OFF 1234
X21A
S1NPH
T2A
X1A
X3A
X2A
Y5S
Y6S
Y7S
Y8S
Y9S
R8T
t˚
R9T
t˚
WHT
S2NPH
RED
X10A
X15A
X37A
X20A
: IS CONNE CTOR COLOR FOR
PRINTED CIRCUIT B OARD.
: IS CONNE CTOR COLOR FOR COMP ONE NT.
: IS DIS CRIMINA TION COLOR FOR
COMP ONE NT LE AD WIRE.
Y1E
5 M
Z6C
X11A X12A
X13A WHT
X16A
R31T R32T
R2T
R5T R6T R7T
H1PH2PH3PH4P
A3P
X4A
t˚
t˚
V1CP
t˚
t˚
t˚
t˚
H5PH6P H7P H8P
X400A
K1R
1 X29A
1
X30A
BS1 BS2 BS3 BS4 BS5
Z1F
X26A
A1RED
X23A
K2M WHT
X28A
A2
X5A
X1M
TO IN/D UNIT TO OUT/D UNIT TO MULTI UNIT
Y2E
5 5
F1U F2U F3 U
K4M
F400U
K3R
X401A
X402A
X403A
F1 F2
F1 F2
Q1 Q2
M
X3A
A4P
X10A
K2M
X1A
X61A Z2C
X6A
CATATAN)5
OUTDOOR (Q1) (Q2)
OUTDOOR (F 1) (F 2)
INDOOR (F 1) (F 2)
X1A
T1A
+
-
V2R
PS
P1
X4A
Z7C
A6P
WHT
L1R
WHT
P2
K1R
R95
N3 Z4C
P3
BLK
RED
R S T
K2M
C66 C63
+ +
R50 R59
A5P
X5A
P1 N1
U V W
X5A
F1U R10
Z8C
+
-
X3A + - X4A
EL. COMPO. BOX
N=5
V1R
X41A
V1R
BACK SIDE
X2A
U V W
Z3C
X11A
X111A
t˚
X1A
Z5C
5
X1A
X2A
A2P
A1P
X1M
M
3~
M2C
N=5
R1T
F 1 U
A 6P
A9P
F 2 U
F 3 U
K 2M
U V W
MS
3~
MS
3~ 5
X1M
(FRONT)
X3A
CATATANS)
M1C
M1F
L1R
1. THIS WIRING DIAGRAM IS APPLIED ONLY TO THE UNIT OUTDOOR.
2.
: FIELD WIRING.
3.
: TERMINAL STRI P
: CONNECTOR : TERMINAL : PROTECTI VE EARTH (SCREW)
4. WHEN USING THE OPTIONAL ADAPTOR, REFER TO THE INSTALLATION MANUAL OF THE OPTIONAL ADAPTOR.
5. FOR CONNECTION WIRING TO INDOOR-OUTDOOR TRANSMISSION F1 · F2, OUTDOOR-OUTDOOR TRANSMISSION F1 · F2,
OUTDOOR-MULTI TRANSMISSION Q1 · Q2, REFER TO THE INSTALLATION MANUAL.
6. HOW TO USE BS1~5 AND DS1 SWITCH, REFER TO "SERVICE PREPERHATIAN " LABEL ON EL. COMPO. BOX, LID.
7. WHEN OPERATING, DON'T SHORTCIRCUIT THE PROTECTION DEVICE (S1PH, S2PH ).
8. COLORS BLK: BLACK RED: RED BLU: BLUE WHT: WHITE PNK: PINK YLW: YELLOW BRN: BROWN GRY: GRAY GRN: GREEN ORG: ORANGE.
(BACK)
3D074550C
M1F
M1C
M2C
OUTE R S HE LL
A4P
A5P
A3P
D
ia
gr
a
m
P
e
n
gk
a
be
la
n
Si
3
4
12
1
3
R
1
0
P
Y
1
/
R
Q
Q
1
2P
Y1
141
R
E
D
W
H
T
B
LK
R
E
D
W
H
T
B
LK
B
LU
R
ED
W
HT
BL
K
G
R
N
W
H
T
B
LU
B
LK
R
ED
W
H
T
BL
K
K4
R
K3
R
K4
R
K7
R
K8
R
K9
R
L1-RED
L2-WHT
L3-BLK
N-BLU
A1P
PRINTED CIRCUIT BOARD (MAIN)
K2R
MAGNETIC RELAY (Y6S) (A2P)
S1NPH
PRESSURE SENSOR (HIGH)
A2P
PRINTED CIRCUIT BOARD (SUB)
K3R
MAGNETIC RELAY (Y1S) (A1P)
S1NPL
PRESSURE SENSOR (LOW)
A3P
P RINTE D CIRC UIT B OA RD (N OIS E FILTE R) K3R
MAGNETIC RELAY (Y7S) (A2P)
S2NPH
PRESSURE SENSOR (HIGH LIQ.)
A4P
PRINTED CIRCUIT BOARD (INV.)
K3R
MAGNETIC RELAY (A3P)
S1PH, S2PH PRESSURE SWITCH (HIGH)
A5P
PRINTED CIRCUIT BOARD (FAN)
K4R
MAGNETIC RELAY (Y2S) (A1P)
T1A
CURRENT SENSOR (A6P)
A6P
PRINTED CIRCUIT B OARD (CURRE NT SENS OR) K4R
MAGNETIC RELAY (Y8S) (A2P)
T2A
CURRENT SENSOR (A9P)
A9P
PRINTED CIRCUIT BOARD (SUB)
K5R
MAGNETIC RELAY (Y9S) (A2P)
V1CP
SAFETY DEVICES INPUT
BS1~5
BS BUTTON
(MODE, SET, RETURN, TEST, RESET)
K7R
MAGNETIC RELAY (E1HC) (A1P)
V1R
POWER MODULE (A4P, A5P)
K8R
MAGNETIC RELAY (E2HC) (A1P)
V2R
DIODE BRIDGE (A4P)
C1
CAPACI TOR
K9R
MAGNETIC RELAY (Y10S) (A1P)
X1A, X2A
CONNECTOR (M1F)
C63, C66
CAPAC I TOR
K11R
MAGNETIC RELAY (Y4S) (A1P)
X3A
CONNECTOR (Y2E)
DS1
DIP SWITCH
L1R
REACTOR
X1M
TERMINAL STRIP (POWER SUPPLY)
E1HC, E2HC CRANKCASE HEATER
M1C, M2C
MOTOR (COMPRESSOR)
X1M
TERMINAL STRIP (CONTROL) (A1P)
F1U
FUSE (T, 3.15A, 250V) (A2P)
M1F
MOTOR (FAN)
Y1E
ELE CTRONIC EX PA NSION V ALVE (MAIN)
F1U
FUSE (8A, DC650V) (A5P)
PS
SWITCHING POWER SUPPLY (A1P, A4P) Y2E
ELECTRONIC EXPANS ION VALVE (S UBCOOLING)
F1U, F2U
FUSE (T, 3.15A, 250V) (A1P)
Q1RP
PHASE REVERSAL DETECT CIRCUIT
Y1S
SOLENOID VALVE (HOT GAS)
F 400U
FUSE (T, 6.3A, 250V) (A3P)
R10
RESISTOR (CURRENT SENSOR) (A5P) Y2S
SOLENOID VALVE (OIL)
F1U-3U
FUSE
R50, R59
RESI STOR
Y4S
SOLENOID VALVE (MIX IN)
H1P~8P
PILOT LA MP (S E RVICE MONITOR-ORA NGE )
[H2P] P REPARE, TEST--------------------FLICKE RING
MALFUNCTION DE TECTION---LIGHT UP
R95
RESISTOR (CURRENT LIMITING)
Y5S
SOLENOID VALVE (RETURN OIL)
R1T
THERMISTOR (AIR) (A1P)
Y6S
SOLENOID VALVE (LIQ. CLOSE)
R1T
THERMISTOR (FIN) (A4P)
Y7S
SOLENOID VALVE (RECEIVER LI Q.)
HAP
PILO T LA MP (S E RV ICE M ONIT OR- G RE E N) R2T
THERMISTOR (RECEIVER)
Y8S
SOLENOID VALVE (RECEIVER GAS)
K2M
MAGNETIC CONTACTOR (M1C) (A4P)
R31T, R32T THERMISTOR (M1C, M2C DISCHARGE) Y9S
SOLENOID VALVE (OIL OUT)
K2M
MAGNETIC CONTACTOR (M2C)
R5T
THERMISTOR (HEAT EXC. OUTLET)
Y10S
SOLENOID VALVE (MAIN BYPASS)
K4M
MAGNETIC CONTACTOR (M1C) (A3P)
R6T
THERMISTOR (LIQ. PIPE)
Z1C~8C
NOISE FILTER (FERRITE CORE)
K1R
MAGNETIC RELAY (K2M) (A1P)
R7T
THERMISTOR (REF. GAS OUT)
Z1F
NOIS E FILTE R ( WITH S U R GE A B S ORB E R)
K1R
MAGNETIC RELAY (Y5S) (A2P)
R8T
THERMISTOR (SUCTION)
CONNECTOR FOR OPTI ONAL PARTS
K1R
MAGNETIC RELAY (A4P)
R9T
THERMISTOR (HEAT EXC. DEICER)
X9A
POWER SUPPLY (ADAPTOR) (A2P)
Содержание VRV III RQQ8-48PY1
Страница 1: ...Pendinginan Saja R 410A 50Hz RQQ8 48PY1 Service Manual Si341213...
Страница 6: ......
Страница 149: ...Si341213 139 Lampiran Bagian 6 Lampiran 1 Diagram Pengkabelan 140 2 Contoh Sambungan 143...
Страница 155: ...Riwayat Revisi Bulan Tahun Versi Isi yang Direvisi 11 2012 Si341213 Edisi Pertama...