background image

• Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE

• VRV

®

 Systems • Indoor Units

132

1

Specifications

In

do

or

 U

ni

t

VR

V  S

ys

te

ms

FX

MQ

-P

VE

Co

nc

ea

le

C

1-1  TECHNICAL SPECIFICATIONS

FXMQ40PVE

FXMQ50PVE

FXMQ63PVE

FXMQ80PVE

FXMQ100PVE

FXMQ125PVE

Capacity

Cooling

kW

4.5

5.6

7.1

9.0

11.2

14.0

Heating

kW

5.0

6.3

8.0

10.0

12.5

16.0

Power Input

Cooling

kW

0.194 (1)
0.193 (2)

0.215 (1)
0.214 (2)

0.230 (1)
0.229 (2)

0.298 (1) 
0.297 (2)

0.376 (1)
0.375 (2)

0.461 (1)
0.460 (2)

Heating

kW

0.182

0.203

0.218

0.286

0.364

0.449

Casing

Material

Galvanised steel plate

Dimensions

Unit

Height

mm

300

300

300

300

300

300

Width

mm

700

1,000

1,000

1,000

1,400

1,400

Depth

mm

700

700

700

700

700

700

Weight

Unit

kg

28

36

36

36

46

46

Heat 
Exchanger

Dimensions

Nr  of  Rows

3

3

3

3

3

3

Fin Pitch

mm

1.75

1.75

1.75

1.75

1.75

1.75

Face 
Area

0.148

0.249

0.249

0.249

0.383

0.383

Nr of Stages

16

16

16

16

16

16

Fan

Type

Sirocco fan

Air Flow Rate

Cooling

High high m³/min

16

18

19.5

25

32

39

High

m³/min

13

16.5

17.5

22.5

27

33

Low

m³/min

11

15

16

20

23

28

Fan

External static 
pressure

High

Pa

160

200

200

200

200

200

Standard Pa

100

100

100

100

100

100

Low

Pa

30

50

50

50

50

50

Motor

Output 
(high)

W

140

350

350

350

350

350

Drive

Direct drive

Piping 
connections

Liquid (OD)

Type

Flare connection

Diameter mm

6.35

9.52

9.52

9.52

9.52

9.52

Gas

Type

Flare connection

Diameter mm

12.7

15.9

15.9

15.9

15.9

15.9

Drain

Diameter mm

VP25 (I.D. 32/O.D. 25)

Refrigerant control

Electronic expansion valve

Temperature control

Microprocessor thermostat for cooling and heating

Safety devices

Fuse

Fan driver overload protector

Standard 
Accessories

Standard Accessories

Operation manual

Installation manual

Drain hose

Sealing pads

Clamps
Washer

Screws

Insulation for fitting

Clamp metal

Air discharge flange

Air suction flange

Legend

(1) 50Hz, 220-240V

(2) 60Hz, 220V

Notes

Nominal cooling capacities are based on following conditions: return air temperature: 27°CDB/19°CWB; outdoor 

temperature: 35°CDB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)

Nominal heating capacities are based on following conditions: return air temperature: 20°CDB; outdoor temperature: 

7°CDB/6°CWB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

External static pressure is changeable in 13 or 14 stages within the ( ) range by the remote control.

Air filter is not standard accessory, but please mount it in the duct system of the suction side.  Select its colorimetric 

method(gravity method) 50% or more.

Содержание VRSIII-S Series

Страница 1: ...technical data Concealed ceiling unit FXMQ PVE air conditioning systems EEDEN08 204 2e...

Страница 2: ...ecifications 3 2 Safety device settings 4 3 Options 4 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 8 6 Dimensional drawing centre of gravity 10 Dimensional...

Страница 3: ...irect drive Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 9 52 9 52 9 52 Gas Type Flare connection Diameter mm 12 7 15 9 15 9 15 9 15 9 15 9 Drain Diameter mm VP25 I D...

Страница 4: ...mum fuse amps MFA A 16 16 16 16 16 16 Full load amps FLA A 1 1 1 3 1 4 1 8 2 3 2 7 Voltage range Minimum V 10 Maximum V 10 Notes Voltage range units are suitable for use on electrical systems where vo...

Страница 5: ...443 NOTE 1 See the latest for the modification marks Model DUCT TYPE Item FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE High efficiency filter 65 KAF372AA56 KAF372AA80 KAF372AA160 90 K...

Страница 6: ...ensor KRCS01 1B 7 Mounting plate for adapter PCB Note 2 3 KRP4A96 8 Central remote control DCS302CA61 8 1 Electrical box with earth terminal 3 blocks KJB311AA 9 Unified on off control DSC301BA61 9 1 E...

Страница 7: ...5 4 1 5 2 4 5 5 6 4 6 5 9 4 6 6 0 4 4 6 1 3 7 33 0 3 8 3 6 4 5 4 1 5 2 4 5 5 6 4 6 5 8 4 5 5 9 4 3 6 0 3 7 35 0 3 8 3 6 4 5 4 1 5 2 4 5 5 6 4 6 5 7 4 5 5 8 4 3 5 9 3 6 37 0 3 8 3 6 4 5 4 1 5 2 4 5 5...

Страница 8: ...6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 5 8 5 11 8 8 2 12 1 7 9 35 0 7 6 6 4 9 0 7 3 10 5 8 3 11 2 8 5 11 3 8 4 11 6 8 1 11 9 7 8 37 0 7 6 6 4 9 0 7 3 10 5 8 3 11 0 8 4 11 2 8 3 11 4 8 0 11 7 7 7 39 0 7 6 6...

Страница 9: ...8 5 8 5 8 5 5 3 0 2 2 6 2 6 2 6 2 6 1 5 9 5 5 5 0 4 1 6 4 6 4 6 3 6 1 5 9 5 5 7 0 6 0 6 6 6 6 6 3 6 1 5 9 5 5 9 0 7 9 6 8 6 7 6 3 6 1 5 9 5 5 11 0 9 8 7 0 6 7 6 3 6 1 5 9 5 5 13 0 11 8 7 1 6 7 6 3 6...

Страница 10: ...9 5 0 4 1 12 7 12 7 12 5 12 1 11 7 10 9 7 0 6 0 13 1 13 1 12 5 12 1 11 7 10 9 9 0 7 9 13 5 13 3 12 5 12 1 11 7 10 9 11 0 9 8 14 0 13 3 12 5 12 1 11 7 10 9 13 0 11 8 14 1 13 3 12 5 12 1 11 7 10 9 15 0...

Страница 11: ...ntrol box Arrow view B 2 According to any one of below 1 3 secure a space for service works such as checking and maintenance of control box and drain pumps etc FXMQ50 63 80P 3D060161 12 Drain hose acc...

Страница 12: ...M10 9 Air suction flange 8 Air discharge flange 7 Power supply connection 6 Interunit wiring connection 5 Control box inside 4 Ground terminal in control box M4 3 Drain pipe connection VP25 O D 32 I...

Страница 13: ...hatch 450mmx450mm Inspection hatch 450 Control box Control box Control box Inspection hatch 3 or more or less or more or more NOTES 1 Location of MANUFACTURE S LABEL Control box surface 2 Mount the a...

Страница 14: ...VRV Systems Indoor Units 143 Indoor Units CONCEALED CEILING UNIT FXMQ PVE 6 Dimensional drawing centre of gravity 6 2 Centre of gravity FXMQ P 4D060438 MODEL NAME FXMQ40P FXMQ50 63 80P FXMQ100 125P...

Страница 15: ...ts CONCEALED CEILING UNIT FXMQ PVE VRV Systems Indoor Units 144 7 Piping diagram FXMQ P 4D034245C Heat exchanger Fan Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expan...

Страница 16: ...250V R2T Thermistor liquid Wired remote control F2U Fuse T 5A 250V R3T Thermistor gas R1T Thermistor air F3U Fuse T 6 3A 250V R4T Thermistor discharge air SS1 Selector switch main sub F4U Fuse T 6 3A...

Страница 17: ...hreshold hearing for continuous noise FXMQ50P Scale Air flow rate HH H L A 41 0 39 0 37 0 C 46 0 44 0 42 0 Discharge Suction 1m 2m Duct Duct 1 5m Microphone 4D060447 NOTES 1 Over All dB B G N is alrea...

Страница 18: ...hreshold hearing for continuous noise FXMQ100P Scale Air flow rate HH H L A 43 0 41 0 39 0 C 49 0 46 0 44 0 Discharge Suction 1m 2m Duct Duct 1 5m Microphone 4D060449 NOTES 1 Over All dB B G N is alre...

Страница 19: ...e value in this figure shows ESP in rating air flow Range of available air flow rate in HH rating EPS HH rating ESP L rating ESP HH min ESP L min ESP mmH2O mmH2O mmH2O mmH2O FXMQ80P 3D060459 External...

Страница 20: ...ons are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage In the broadest sense arising from or related to the use and or inte...

Отзывы: