• Indoor Units • CONCEALED CEILING UNIT • FXMQ-PVE
• VRV
®
Systems • Indoor Units
132
1
Specifications
In
do
or
U
ni
t
VR
V S
ys
te
ms
FX
MQ
-P
VE
Co
nc
ea
le
d
C
1-1 TECHNICAL SPECIFICATIONS
FXMQ40PVE
FXMQ50PVE
FXMQ63PVE
FXMQ80PVE
FXMQ100PVE
FXMQ125PVE
Capacity
Cooling
kW
4.5
5.6
7.1
9.0
11.2
14.0
Heating
kW
5.0
6.3
8.0
10.0
12.5
16.0
Power Input
Cooling
kW
0.194 (1)
0.193 (2)
0.215 (1)
0.214 (2)
0.230 (1)
0.229 (2)
0.298 (1)
0.297 (2)
0.376 (1)
0.375 (2)
0.461 (1)
0.460 (2)
Heating
kW
0.182
0.203
0.218
0.286
0.364
0.449
Casing
Material
Galvanised steel plate
Dimensions
Unit
Height
mm
300
300
300
300
300
300
Width
mm
700
1,000
1,000
1,000
1,400
1,400
Depth
mm
700
700
700
700
700
700
Weight
Unit
kg
28
36
36
36
46
46
Heat
Exchanger
Dimensions
Nr of Rows
3
3
3
3
3
3
Fin Pitch
mm
1.75
1.75
1.75
1.75
1.75
1.75
Face
Area
m²
0.148
0.249
0.249
0.249
0.383
0.383
Nr of Stages
16
16
16
16
16
16
Fan
Type
Sirocco fan
Air Flow Rate
Cooling
High high m³/min
16
18
19.5
25
32
39
High
m³/min
13
16.5
17.5
22.5
27
33
Low
m³/min
11
15
16
20
23
28
Fan
External static
pressure
High
Pa
160
200
200
200
200
200
Standard Pa
100
100
100
100
100
100
Low
Pa
30
50
50
50
50
50
Motor
Output
(high)
W
140
350
350
350
350
350
Drive
Direct drive
Piping
connections
Liquid (OD)
Type
Flare connection
Diameter mm
6.35
9.52
9.52
9.52
9.52
9.52
Gas
Type
Flare connection
Diameter mm
12.7
15.9
15.9
15.9
15.9
15.9
Drain
Diameter mm
VP25 (I.D. 32/O.D. 25)
Refrigerant control
Electronic expansion valve
Temperature control
Microprocessor thermostat for cooling and heating
Safety devices
Fuse
Fan driver overload protector
Standard
Accessories
Standard Accessories
Operation manual
Installation manual
Drain hose
Sealing pads
Clamps
Washer
Screws
Insulation for fitting
Clamp metal
Air discharge flange
Air suction flange
Legend
(1) 50Hz, 220-240V
(2) 60Hz, 220V
Notes
Nominal cooling capacities are based on following conditions: return air temperature: 27°CDB/19°CWB; outdoor
temperature: 35°CDB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)
Nominal heating capacities are based on following conditions: return air temperature: 20°CDB; outdoor temperature:
7°CDB/6°CWB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
External static pressure is changeable in 13 or 14 stages within the ( ) range by the remote control.
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its colorimetric
method(gravity method) 50% or more.