6  AFTER-SALES SERVICE

After-sales service: 

WARNING

  Do not modify the unit. 

This may cause electric shoc

e.

  Do not disassemble or repair the unit.

This may cause electric shoc

e.

Contact your dealer.

  Do not remove or reinstall the unit by yourself.

Incomplete installation may cause a water leakage 

electric shoc

e.

Contact your dealer.

 

When asking your dealer to repair, inform 

  Shipping date and installation date:

  Malfunction: 

Infor

fective details.

(Malfunction code being displayed on the 

remote controller.)

  Name, ad

dress, telephone number

 

Repair where the warranty term is expired
Contact your dealer. If necessary to repair, pay 

service is available.

 

Minimum storage period of important parts
Even after a certain type of the Heat Reclaim 

Ventilator unit is discontinued, we have the related 

important parts in stock for 6 years at least.

The important parts indicate parts essential to 

operate the Heat Reclaim Ventilator unit.

 

Recommendations for maintenance and 

inspection
Since dust collects after using the unit for several 

years, the performance will be deteriorated to some 

extent.

Taking apart and cleaning inside require 

technical expertise, so we recommend entering a 

maintenance and inspection contract (at a cost) 

separate from normal maintenance.

 

Recommended inspection and maintenance 

cycles
[Note: The maintenance cycle is not the same 

as the warranty period.]

   Table 1 assumes the following usage conditions.

 Normal use without frequent starting and 

stopping of the machine.

 (Although it varies with the model, we recommend 

not start-ing and stopping the machine more than 

6 times/hour for normal use.)

   Operation of the product is assumed to be 

10 hours/day, 2500 hours/year.

   Table 1. “Inspection Cycle” and “Maintenance Cycle” 

Lists

Name of Main Part

Inspection 

Cycle

Maintenance 

Cycle

[Replacements 

and/or repairs]

Electric 

motor

For fan (Note 3)

1 to 2 

months

20,000 hours

For damper

Printed circuit boards

1 year

Name of Main Part

Inspection 

Cycle

Maintenance 

Cycle

[Replacements 

and/or repairs]

Heat exchange element

1 year

6 to10 years

r

a

e

y

 

5

 

)

r

o

t

s

i

m

r

e

h

t

r

o

s

n

e

S
Remote control and 

switches

25,000 hours

NOTE 1 

  This table indicates main parts. See the 

maintenance and inspection contract for details. 

NOTE 2 

  This maintenance cycle indicates the 

recommended duration until the need arises for 

maintenance work; this ensures the product is 

operational for as long as possible.

  Use it for appropriate maintenance design 

(budgeting maintenance and inspection fees, etc.).

  Depending on the content of the maintenance 

and inspection contract, the inspection and 

maintenance cycles may in reality be shorter than 

those listed here.

NOTE 3 

  Using the unit with a failed motor will lead to 

ventilation.

  It is recommended to have the motor inspected 

once every 1 to 2 months. (Simple check)

  Motor performance can be examined with a stick 

and string or similarly lightweight item attached to 

the tip and held at the air supply grille and exhaust 

grille for movement.

NOTE 4 

  Shortening of “maintenance cycle” and 

“replacement cycle” needs to be considered if the 

unit is used under severe operation conditions (long 

operating hours, very frequent ON/OFF, etc.) and 

harsh operating environment (high temperature, 

high humidity, etc.). 

For details, contact your dealer or the contact center.

1-OM-VAM-HVE-DAIKIN-EN.indd   10

23/9/2021   2:29:06 PM

25,000 hours

Содержание VAM150HVE

Страница 1: ...0HVE VAM250HVE VAM350HVE VAM500HVE VAM650HVE VAM800HVE VAM1000HVE VAM1500HVE VAM2000HVE Total Heat Exchanger Heat Reclaim Ventilator For Production only For Indonesia For Thailand For Vietnam 3P645002...

Страница 2: ...CVR OM VAM HVE DAIKIN EN indd 2 CVR OM VAM HVE DAIKIN EN indd 2 23 9 2021 5 08 50 PM 23 9 2021 5 08 50 PM...

Страница 3: ...any problems or there is a malfunction please refer to this operation manual Please keep this manual for your future reference whenever you do not understand how to use it when something is wrong with...

Страница 4: ...exchange element may be noticeable it is not harmful The smell will gradually go away as the unit is used It exchanges the indoor heat with the outdoor air conditioning the outdoor air closer to the a...

Страница 5: ...s Connection chamber Damper 2 pcs Air supply fan 2 pcs Air filter 4 pcs Remote control optional accessory Electrical component box Name plate Heat exchange elements 4 pcs Open and close it when cleani...

Страница 6: ...eat Reclaim Ventilator unit Centralized controller Remote controller for Heat Reclaim Ventilator unit BRC1H62W K Remote controller for indoor unit Heat Reclaim Ventilator unit Combined operation syste...

Страница 7: ...4 MODELS VAM150HVE VAM1000HVE MODELS VAM1500HVE VAM2000HVE Air filter Air filter 5 6 7 8 1 OM VAM HVE DAIKIN EN indd 5 1 OM VAM HVE DAIKIN EN indd 5 23 9 2021 2 29 05 PM 23 9 2021 2 29 05 PM...

Страница 8: ...r dealer Young children should be supervised to ensure that they do not play with the appliances It may make your health worse by wrong operation Do not use heating appliances nearby the Heat Reclaim...

Страница 9: ...one earth Incomplete earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker F...

Страница 10: ...intenance space for the air filters the heat exchange elements and control box 16 RA Return air from room 17 SA Supply air to room 2 2 VENTILATION OPERATION See the operation manual of the remote cont...

Страница 11: ...rature is higher than the temperature setting of the air conditioner combined 2 The outdoor temperature is lower than the indoor temperature If the above conditions are not met reevaluation is made ev...

Страница 12: ...at exchanger unit with water not including air filters If the electrical parts or motors get wet with water it may cause electric leakage resulting in electric shock or fire Be sure to stop the operat...

Страница 13: ...durability Do not wash the air filter with hot water of more than 50 C This may cause discoloration or deformation Do not expose the air filter to fire This may result in burning Do not expose the ai...

Страница 14: ...all the maintenance cover 4 1 3 HOW TO INSTALL AND REPLACE THE HIGH PERFORMANCE FILTER OPTIONAL ACCESSORY Replace the high performance filter at least once a year Increase the frequency of replacement...

Страница 15: ...ror code Usage under that status will lead to insufficient ventilation The air supply and exhaust fans should be checked once every one or two months You can make a simple check such as below way To c...

Страница 16: ...the unit presents abnormal conditions burnt smell etc stop the operation and turn the breaker off Continued operation under such circumstances may result in a failure electric shock or fire Contact y...

Страница 17: ...ore than 6 times hour for normal use Operation of the product is assumed to be 10 hours day 2500 hours year Table 1 Inspection Cycle and Maintenance Cycle Lists Name of Main Part Inspection Cycle Main...

Страница 18: ...for appropriate maintenance design budgeting parts replacement cost etc If the unit is used for a building for The Building Sanitation Act Former Buiding Managment Act periodic inspection is required...

Страница 19: ...CVR OM VAM HVE DAIKIN EN indd 3 CVR OM VAM HVE DAIKIN EN indd 3 23 9 2021 5 08 50 PM 23 9 2021 5 08 50 PM...

Страница 20: ...Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan http www daikin com global Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Mal...

Отзывы: