3-2  NIGHTTIME FREE COOLING 

OPERATION 

The nighttime free cooling is an energy-saving 
function which works at night when the air 
conditioners is off; reducing the cooling load in the 
morning when the air conditioner is turned on by 
ventilating rooms which contain office equipment 
which raises the room temperature.
•  Nighttime free cooling operation can be performed 

as stand-alone operation or combined operation.

•  The operation lamp on the remote control is OFF 

during the nighttime free cooling operation.

• Nighttime free cooling is set to “off” in the factory 

settings. Request your dealer to turn it on if you intend 
to use it.

COMBINED NIGHTTIME FREE COOLING 
OPERATION

OFF

ON

OFF

OFF

22:00

24:00

40

30

20

Outdoor 
temperature

Indoor 
temperature

Set temperature

Nighttime free cooling operation

Following morning 
(time)

T

emper

ature

T

otal heat 

e

xchanger

Air 

conditioner

Nighttime free cooling only works during cooling and 
when combined with Sky Air or VRV systems.

<

Unit operation

>

The unit compares the indoor and outdoor 
temperatures after the air conditioner stops for the 
night. If the following conditions are met, the operation 
starts and when the indoor temperature reaches 
the temperature setting of the air conditioner, the 
operation stops.

Conditions;

1. The indoor temperature is higher than the 

temperature setting of the air conditioner combined.

2. The outdoor temperature is lower than the indoor 

temperature.

If the above conditions are not met, reevaluation is 
made every 60 minutes.

The product’s method of use varies according to 
each system.

Check with the dealer on what system has the product 
been installed with prior to operation. 

For operations of remote controls and centralized 
controller, see their respective operation manual.

NOTE 

•  When the fan motor fails, the remote controller does 

not display any error code.
Usage under that status will lead to insufficient 
ventilation.
The air supply and exhaust fans should be checked 
once every one or two months.
You can make a simple check such as below way.
To check the wind flow, hold a bar of which the end 
has a string or other similar lightweight item over 
the supply grille and exhaust grille.

3 OPERATION PROCEDURE

3-1  24-HOUR VENTILATION 

OPERATION

The 24-hour ventilation operation is an automatic 
function that provides ventilation even after the 
operation has been stopped in order to prevent sick 
building and sick school syndrome.
After the operation is stopped, the unit switches to 
continuous operation at low fan speed or intermittent 
operation.
•  

24-hour ventilation operation is set to “off” in the 
factory settings.
Request your dealer to turn it on if you intend to use 
it.

1-OM-VAM-HVE-DAIKIN-EN.indd   4

1-OM-VAM-HVE-DAIKIN-EN.indd   4

23/9/2021   2:29:06 PM

23/9/2021   2:29:06 PM

Содержание VAM150HVE

Страница 1: ...0HVE VAM250HVE VAM350HVE VAM500HVE VAM650HVE VAM800HVE VAM1000HVE VAM1500HVE VAM2000HVE Total Heat Exchanger Heat Reclaim Ventilator For Production only For Indonesia For Thailand For Vietnam 3P645002...

Страница 2: ...CVR OM VAM HVE DAIKIN EN indd 2 CVR OM VAM HVE DAIKIN EN indd 2 23 9 2021 5 08 50 PM 23 9 2021 5 08 50 PM...

Страница 3: ...any problems or there is a malfunction please refer to this operation manual Please keep this manual for your future reference whenever you do not understand how to use it when something is wrong with...

Страница 4: ...exchange element may be noticeable it is not harmful The smell will gradually go away as the unit is used It exchanges the indoor heat with the outdoor air conditioning the outdoor air closer to the a...

Страница 5: ...s Connection chamber Damper 2 pcs Air supply fan 2 pcs Air filter 4 pcs Remote control optional accessory Electrical component box Name plate Heat exchange elements 4 pcs Open and close it when cleani...

Страница 6: ...eat Reclaim Ventilator unit Centralized controller Remote controller for Heat Reclaim Ventilator unit BRC1H62W K Remote controller for indoor unit Heat Reclaim Ventilator unit Combined operation syste...

Страница 7: ...4 MODELS VAM150HVE VAM1000HVE MODELS VAM1500HVE VAM2000HVE Air filter Air filter 5 6 7 8 1 OM VAM HVE DAIKIN EN indd 5 1 OM VAM HVE DAIKIN EN indd 5 23 9 2021 2 29 05 PM 23 9 2021 2 29 05 PM...

Страница 8: ...r dealer Young children should be supervised to ensure that they do not play with the appliances It may make your health worse by wrong operation Do not use heating appliances nearby the Heat Reclaim...

Страница 9: ...one earth Incomplete earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker F...

Страница 10: ...intenance space for the air filters the heat exchange elements and control box 16 RA Return air from room 17 SA Supply air to room 2 2 VENTILATION OPERATION See the operation manual of the remote cont...

Страница 11: ...rature is higher than the temperature setting of the air conditioner combined 2 The outdoor temperature is lower than the indoor temperature If the above conditions are not met reevaluation is made ev...

Страница 12: ...at exchanger unit with water not including air filters If the electrical parts or motors get wet with water it may cause electric leakage resulting in electric shock or fire Be sure to stop the operat...

Страница 13: ...durability Do not wash the air filter with hot water of more than 50 C This may cause discoloration or deformation Do not expose the air filter to fire This may result in burning Do not expose the ai...

Страница 14: ...all the maintenance cover 4 1 3 HOW TO INSTALL AND REPLACE THE HIGH PERFORMANCE FILTER OPTIONAL ACCESSORY Replace the high performance filter at least once a year Increase the frequency of replacement...

Страница 15: ...ror code Usage under that status will lead to insufficient ventilation The air supply and exhaust fans should be checked once every one or two months You can make a simple check such as below way To c...

Страница 16: ...the unit presents abnormal conditions burnt smell etc stop the operation and turn the breaker off Continued operation under such circumstances may result in a failure electric shock or fire Contact y...

Страница 17: ...ore than 6 times hour for normal use Operation of the product is assumed to be 10 hours day 2500 hours year Table 1 Inspection Cycle and Maintenance Cycle Lists Name of Main Part Inspection Cycle Main...

Страница 18: ...for appropriate maintenance design budgeting parts replacement cost etc If the unit is used for a building for The Building Sanitation Act Former Buiding Managment Act periodic inspection is required...

Страница 19: ...CVR OM VAM HVE DAIKIN EN indd 3 CVR OM VAM HVE DAIKIN EN indd 3 23 9 2021 5 08 50 PM 23 9 2021 5 08 50 PM...

Страница 20: ...Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan http www daikin com global Lot 60334 Persiaran Bukit Rahman Putra 3 Taman Perindustrian Bukit Rahman Putra 47000 Sungai Buloh Selangor Darul Ehsan Mal...

Отзывы: