PIM00424
3-3
If it continuously operate at the highest pressure, please follow the flow rate requirement showing in the table
below.
Product type
Flow rate
SUT00S8007-30
SUT10S8007-30
19L/min or less
SUT00D8021-30
SUT10D8021-30
SUT16D8021-30
14L/min or less
Please check product specifications (in the format drawing) for other specifications.
3.2.2
Common Specifications
(
Note 1
)
Please contact us if other kinds of oil besides mineral hydraulic oil (water-glycol) are going
to be used.
(
Note 2
)
Even in the tolerance range, if the change is + side,
there is a possibility that when
Hydraulic oil
(Note 1)
Dedicated mineral hydraulic oil / Wear-resistant hydraulic oil (For recommended brands,
refer to DAIKIN "Hydraulic Equipment General Catalog (HK196)".)
・
Viscosity grade: ISO VG 32 to 68
・
Viscosity range: 15 to 400 mm2/s
・
Pollution degree: NAS Class 9 or lower level
Power supply
3
φ
200V/50Hz
200V/60Hz
220V/60Hz
Power supply voltage fluctuation tolerance range is ±10%.
(Note2)
External input signal
(3ch)
Photocoupler isolation, DC24V (up to 27V) 5mA/1ch
External output signal
(relay output) (1ch)
Relay output contact capacity: DC30V 0.5A (resistance of load) 1c contact
External output signal
(dry contacts) (2ch)
Photocoupler isolation, open collector output DC24V 50mA or less / 1ch
Standard paint color
Ivory white (Munsell 5Y7.5 / 1)
Tank oil temperature
0 to 60
℃
(recommended operating temperature range: 15 to 50
℃
)
(Note3)
Operating ambient
temperature
0 to 40
℃
Storing ambient
temperature
-20 to 60
℃
Humidity
85% RH or less ( No condensation)
Height above the sea
level
1,000 m or less
Installation place
Indoor (Be sure to fasten the unit with bolts.)
Others
・
Be sure to mount a no-fuse breaker (three-pole) in main power supply circuit.
・
Make sure that the electric wiring conforms to European Norm EN60204-1.
・
If you frequently turn ON/OFF the power supply for this unit, the controller service life
will be remarkably deteriorated. If you intend to start and stop the unit at intervals of
eight minutes or less, use the start/stop signal function of this unit. However, if the start-
stop function is being used, please make sure the interval time is upto one minute or
more.
・
Be sure to connect the ground terminal.
Содержание Super Unit SUT00S8007-30
Страница 2: ......
Страница 12: ......
Страница 19: ...PIM00424 3 5 3 4 Dimensions Motor Pump Type SUT00 SUT00S8007 30 ...
Страница 20: ...PIM00424 3 6 SUT00D8021 30 ...
Страница 21: ...PIM00424 3 7 Unit Type SUT10 SUT16 SUT10S8007 30 ...
Страница 22: ...PIM00424 3 8 SUT10D8021 30 ...
Страница 23: ...PIM00424 3 9 SUT16D8021 30 ...
Страница 28: ......
Страница 32: ......
Страница 34: ......
Страница 38: ......
Страница 42: ......
Страница 50: ......
Страница 60: ......
Страница 92: ......