Daikin STREAMER MCK55W Скачать руководство пользователя страница 4

3

Safety Precautions

 

„

Observe these precautions in order to prevent property damage or injury.

 

„

The consequences of incorrect use are categorised as follows:

 

WARNING

 

CAUTION

Failure to follow these instructions properly 

may result in personal injury or loss of life.

Failure to follow these instructions properly may 

result in property damage or personal injury, which 

may be serious depending on the circumstances.

 

„

Precautions to be observed are categorised using symbols:

Never attempt.

Be sure to follow the instructions.

 

 

WARNING  

Observe in order to prevent fire, electric shock or severe injury.

 

„

Concerning the power supply plug and cord

• 

Do not unplug while the unit is in operation. 

(Fire due to overheating or electric shock may result)

• 

Do not plug in or unplug with wet hands. 

(An electric shock may result)

• 

Do not use in such a way that the ratings of the power socket or wiring appliances 

are exceeded or use a voltage outside of the range AC220-240V.

 

(Fire may result from overheating if the ratings of multi-socket power adapters, etc., are exceeded)

• 

Do not pull on the power supply cord when unplugging.

 

(Overheating or fire may result from wire breakage)

• 

Do not perform actions that might break the power supply plug and cord.

 

Such actions including damaging, modifying, forcibly bending, pulling, twisting, bundling up, placing heavy objects on 

the power supply plug or cord. 

If the power supply plug or cord is damaged, it must be replaced by the manufacturer, its service agent, or a similar 

qualified person in order to avoid a hazard.  (An electric shock, short circuiting or fire may result from use while 

damaged)

• 

Insert the power supply plug firmly all the way in.

 

Do not use a damaged power supply plug or a loosely fitted power socket. 

 

(Electric shock, short circuiting or fire due to overheating may result if the power supply plug is not firmly inserted)

• 

Periodically wipe dust off the power supply plug with a dry cloth.

 

If the unit is not to be used for a prolonged period, unplug the power supply.  

(Fire may be caused by defective insulation resulting from dust buildup with moisture, etc.)

• 

When performing maintenance, inspecting, moving the unit, or refilling the water 

tank, be sure to turn off and unplug the unit.

 

(An electric shock or injury may result)

 

„

Do not use in the following places

• 

Places where oil or flammable gases are used or may leak.

 

(Fire or smoke may result from 

ignition or suction toward the unit, or injury may result from degradation or cracking of plastic)

• 

Places where there are corrosive gases or metal dust particles.  

(Fire or smoke may result from ignition or suction toward the unit)

• 

Places where temperature and humidity levels are high or water may scatter, such 

as a bathroom.

 

(Fire or an electric shock may result from electrical leakage)

• 

Places accessible to small children.

 

(An electric shock or injury may result)

• 

Places where the floor is unstable.

  

(Household items etc., may get wet, or a fire or an electric shock may result if the unit falls over)

Read First

01_EN_3P595628-1B.indd   3

2020/04/17   15:48:58

Содержание STREAMER MCK55W

Страница 1: ...ad the operation manual carefully and follow it for correct use Please read the Safety Precautions section before use Please keep the operation manual in a safe place for later reference Humidifying A...

Страница 2: ...1 01_EN_3P595628 1B indd 1 2020 04 17 15 48 57...

Страница 3: ...cifications 38 Operation Using Air Purifying Operation 15 Changing the Airflow Rate 16 Using Humidifying and Air Purifying Operation 16 Adjusting the Humidity 16 Maintenance Maintenance Quick Referenc...

Страница 4: ...ed it must be replaced by the manufacturer its service agent or a similar qualified person in order to avoid a hazard An electric shock short circuiting or fire may result from use while damaged Inser...

Страница 5: ...if the switch is turned on Current passes through the cord or fails to pass through if the cord is moved There are abnormal sounds or vibrations during operation The casing of the unit has become defo...

Страница 6: ...fying tray and humidifying filter unit at all times Replace the water in the water tank with fresh tap water everyday Discard any water remaining in the humidifying tray everyday Periodically perform...

Страница 7: ...ot be detected and indicated correctly Positions near combustion based heating devices or exposed to direct airflow from heating appliances Room humidity may not be detected and indicated correctly or...

Страница 8: ...3 Temperature sensor and Humidity sensor Inside the air inlet left side Model name Production no Manufacturing date MFG DATE Air inlets Front Side Power supply cord Power supply plug Main Removable Pa...

Страница 9: ...etween FAN settings and MODEs Page 16 18 HUM ON OFF button Each press turns the Humidifying operation ON or OFF Page 16 ON OFF button Press to turn the power ON or OFF Page 15 ON OFF button Press to t...

Страница 10: ...the active humidity setting 3 settings Low Standard High 3 Dust sensor lamp PM2 5 sensor lamp Indicates the volume of ambient dust in 3 colours green orange red Green indicates that the air is clean...

Страница 11: ...e approx If odour intensity levels are unchanging the sensor may not respond even if there is a strong odour in the air The following types of odours may not be detected pet odours that do not include...

Страница 12: ...tach the casters with locks to the corners at the front of the unit Casters with locks Lock lever Casters without locks Attach so that this side faces toward the front of the unit Viewed from below At...

Страница 13: ...the frame set the deodorising filter under the hooks small in 2 places 3 In the same way set the deodorising filter under the hook large to attach it Hook small Deodorising filter Hook large Hook smal...

Страница 14: ...to the humidifying tray 1 Insert 2 Fully press below the lever until you hear a catching sound Water tank Humidifying tray Attention As leaving any residual water in the humidifying tray will lead to...

Страница 15: ...ry 1 Move the catch on the battery tray at the bottom of the remote controller in the direction of the arrow 2 Pull out the battery tray 3 Replace the battery 4 Return the battery tray to its original...

Страница 16: ...ss Press again to turn OFF ON OFF lamp green lights up If the Humidifying operation was running previously the Humidifying operation will start automatically the next time the unit is turned ON To use...

Страница 17: ...uild up be sure to discard any residual water in the humidifying tray each time the water tank is refilled Air purification is always performed with humidification It is not possible to run the Humidi...

Страница 18: ...IST Unit Press Each press cycles between the MODE lamps green and FAN lamps green AUTO FAN ECONO ANTI POLLEN MOIST Turbo Standard Low Quiet FAN MODE FAN Note The humidifier is turned ON when MOIST MOD...

Страница 19: ...wer consumption Streamer OFF OFF Humidifying Active plasma ion OFF If the humidity level falls or dust or odours are detected 2 The humidifier ON OFF lamp remains lit up 2 As the FAN setting is limite...

Страница 20: ...hen child proof lock is active child proof lock is turned off The child proof lock lamp orange lights up when the function is active Adjusting Indicator Lamp Brightness Indicator lamp brightness is ad...

Страница 21: ...is recommended that the streamer be set to Regular as deodorising capacity is reduced when set to Low Settings are remembered even if the unit is unplugged Blinking Lit up When you want to turn off a...

Страница 22: ...setting change can be performed when the unit is on or off 2 Release both buttons when a short beep sounds One of the FAN lamps Low Standard Turbo will blink for about 5 seconds and then the lamp corr...

Страница 23: ...will remain lit up To turn Monitoring mode ON Turn on the ECONO MODE lamp Setting at time of purchase ON OFF To turn Monitoring mode OFF Turn off the ECONO MODE lamp Setting is indicated using the EC...

Страница 24: ...ge damage of the filter may result Removing Grip the notch in the pre filter and pull 1 Grip either end of the pre filter resting your thumb against the unit 2 Pull toward you Attaching Insert the hoo...

Страница 25: ...nd removal attachment refer to Page 25 About every 3 days or when odour or dirt becomes an issue Wash Rinse Deodorising Filter Unit Page 28 When odour or dirt becomes an issue Vacuum clean Do not use...

Страница 26: ...with water Use a soft cloth or brush to clean hard to reach places For areas on the tray with water scales clean with a soft cloth or brush soaked in lukewarm or room temperature water in which citri...

Страница 27: ...ps If water scales are not removed and the unit continues to be operated reduced humidifying capacity and water leakage may result Each season clean using citric acid or lemon juice Precautions when c...

Страница 28: ...h frame with the holes in each filter Water leakage may result if not correctly attached Illustration is example of the frame lower half and the humidifying filter blue Insert filter securely under ea...

Страница 29: ...he top of the deodorising filter unit and lift the part up and out Deodorising filter unit Grip 4 Remove the dust collection filter Dust collection filter 1 Pull the filter tag upward 2 Hold the lower...

Страница 30: ...batteries must be treated at a specialized treatment facility for re use recycling and recovery By ensuring correct disposal you will help to prevent potential negative consequences for the environmen...

Страница 31: ...midifying filter unit humidifying tray and water tank attached These lamps may blink if the unit is operated without a part attached If all the parts are attached An electrical component is faulty Con...

Страница 32: ...water If water is used the part will lose its shape and become unusable If you have inadvertently washed it with water contact the place of purchase Remove the deodorising filter unit from the main u...

Страница 33: ...e fluctuation If operating at the time of the voltage fluctuation operation will resume automatically once voltage returns to normal Voltage range protection 180V 264V Sounds can be heard Phenomenon C...

Страница 34: ...the ON OFF lamp and water supply lamp will remain off If indicator lamp brightness is set to OFF after the unit is turned on the brightness of the indicator lamps will be DIM for about 10 seconds and...

Страница 35: ...ivity of the odour sensor will be determined by odour levels in the first minute approx after the power supply plug is inserted every time Page 9 10 To adjust the basic sensitivity of the odour sensor...

Страница 36: ...inlet blocked If they are not blocked an electrical component is faulty Contact the place of purchase Humidifying function Phenomenon Check points Humidification does not occur even though the water...

Страница 37: ...oor humidity is high the walls and floor of the room are moist or the room has good insulation against drafts the target humidity may be exceeded Air purification is always performed with the Humidify...

Страница 38: ...t turn off the power and discard any water in the water tank and humidifying tray Is the cap for the water tank properly and securely tightened If the cap is loose or has been tightened in a tilted fa...

Страница 39: ...tank volume L Approx 2 7 Power supply cord length m 1 8 Made in China These specification values are applicable to both 50Hz 220 240V and 60Hz 220 230V Even when the power is off approx 1W of power is...

Страница 40: ...code is a manufacturing code DAIKIN ISITMA VE SO UTMA S STEMLER SAN T C A G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe STANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00...

Отзывы: