Troubleshooting by Remote Controller
SiUS281117
Service Diagnosis
119
1: Coil check method for the electronic expansion valve coil
Discount the electronic expansion valve from the PCB and check the continuity between the
connector pins.
(Normal)
: Continuity
×: No continuity
Pin No.
1. White
2. Yellow
3. Orange
4. Blue
5. Red
6. Brown
1. White
×
Approx.
300
×
Approx.
150
×
2. Yellow
×
Approx.
300
×
Approx.
150
3. Orange
×
Approx.
150
×
4. Blue
×
Approx.
150
5. Red
×
6. Brown