4. To change the fan speed, press the Fan speed control button

and select the desired fan speed from Low, Medium, or High.

Only two fan speed adjustment levels, low and high may
be available depending on the type of Indoor unit.

The system may be in automatic fan speed control for
equipment protection purposes.

The system may be in automatic fan speed control
according to the room temperature. It is normal for the
fan to intermittently stop operating.

It is normal for a delay to occur when changing the
fan speed.

5. Adjust Air Flow Direction from the Main Menu.

If the connected indoor unit model does not include
oscillating louvers this function will not be available.

6. When the On/Off Button is pressed again, the system will

stop operating and the operation lamp will turn off.

When the system is stopped while in the heating mode,
the fan will continue to operate for approximately one
minute to remove residual heat from the indoor unit.

NOTE: To prevent water damage or system failure, do not
immediately remove power from the indoor unit following
system operation. Wait at least five minutes for the condensate
pump to finish draining residual water from the unit.

CHARACTERISTICS OF HEAT MODE

The system automatically controls the following operating modes
to prevent the reduction of heating capacity and space comfort.

Defrost Operation

The system will automatically go into defrost operation to
prevent frost accumulation at the outdoor unit and loss of
heating capacity.

The indoor unit fan will stop, and “

STANDBY

” (Defrost/Hot

Start) will be displayed on the remote controller.

The system will return to normal operation usually within six
to eight minutes (but not more than 10 minutes).

Hot Start

When the system goes into heat mode, the indoor unit fan
will stop in order to prevent a cold draft. (In that case,

“STANDBY” 

(Defrost/Hot Start) will be displayed on the

remote controller).

DRY MODE

Preparation

For equipment protection purposes, apply power to the
outdoor units at least six hours before“starting the operation
of the system.

The dry mode may not be selected if the remote controller is
master controlled and the system is not already in the cooling
mode of operation.

Operation

1. Press Mode Button several times until the Dry mode is

selected. (The Dry mode may not be available depending
on the type of indoor unit.)

2. Press On/Off Button. The Operation Lamp (green) will

illuminate and the system will start operating. In Dry Mode,
the system maintains automatic temperature and fan speed
control. Therefore, temperature setpoint or fan speed
settings are not available while the indoor unit is in the Dry
Mode.

Содержание SkyAir FTQ18TAVJUA

Страница 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Страница 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Страница 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Страница 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Страница 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Страница 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Страница 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Страница 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Страница 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Страница 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Страница 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Страница 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Страница 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Страница 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...

Отзывы: