11

English

Press the Up/Down buttons to select “Reset Filter
Indicator” on the Main Menu screen and press the Menu/
Enter button.

The display shown in the illustration will disappear from
the basic screen when the filter sign is reset.

START UP AFTER A LONG STOP

1. Confirm the following:

Check that the air inlet and outlet are not blocked.

Remove any obstacle

Check if the ground is connected. Might there be a

broken wire somewhere?

Contact a dealer if there are any problems.

2. Clean the air filter.

After cleaning the air filter, make sure to attach it.

3. Turn on the main power supply switch

The display on the remote controller will be shown when

the power is turned on.

To protect the unit, turn on the main power switch at

least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE SYSTEM FOR
A LONG PERIOD

1. Turn on FAN OPERATION for a half day and dry the unit.

Read the operation manual that came with the remote
controller.

2. Shut off the power supply.

When the main power switch is shut on, some watts of

electricty is being used even if the system is not operating.

Turn off the main power supply switch for saving energy.

The display on the remote controller will vanish when

the main power switch is turned off.

3. Clean the air filter and the exterior.

Be sure to replace the air filter to its original place after

cleaning. Refer to “HOW TO CLEAN THE AIR FILTER.”

ELECTRICAL HEATER REPLACEMENT INTERVAL

The electric heater should be replaced every 10 years.

This replacement interval is a guideline for ensuring safe
and trouble-free operation of the product for many years.

9.  MALFUNCTIONS NOT RELATED TO HEAT

PUMP

The following symptoms do not indicate heat pump malfunction:

I.

THE SYSTEM DOES NOT OPERATE

The system does not restart immediately after the ON/
OFF button is pressed.

 If the OPERATION lamp lights,

the system is in normal condition. It does not restart
immediately because a safety device operates to prevent
overload of the system. After 3 minutes, the system will turn
on again automatically.

The system does not restart immediately when
TEMPERATURE SETTING button is returned to the
former position after pushing the button.

 If the

OPERATION lamp lights, the system is in normal condition.
It does not restart immediately because a safety device
operates to prevent overload of the system. After 3 minutes,
the system will turn on again automatically.

The system does not start when the display shows
“CENTRAL CONTROL” and it flashes for few seconds
after pressing an operation button.

 This is because the

system is under centralized control. Flashes on the display
indicate that the system cannot be controlled by the remote
controller.

The system does not start immediately after the power
supply is turned on.

 Wait one minute until the micro

computer is prepared for operation.

II. The fan speed is different from the setting.

Pressing the fan speed control button does not change
the fan speed.

When the room temperature reaches the set temperature in
heating mode, the outdoor unit stops and the indoor unit
switches to whisper mode. This is to prevent the cool air
from being blown directly onto anyone in the room.

To protect electric parts, the unit operates with the airflow
rate at H speed during ELECTRIC HEATER operation
regardless of the remote controller indication.

III. WHITE MIST COMES OUT OF A UNIT

When humidity is high during cooling operation (In oily
or dusty places) 

If the inside of an indoor unit is extremely

contaminated, the temperature distribution inside a room
becomes uneven. It is necessary to clean the inside of the
indoor unit. Ask your Daikin dealer for details on cleaning
the unit. This operation requires a qualified service person.

Содержание SkyAir FTQ18TAVJUA

Страница 1: ...glish Fran ais Espa ol ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL ADJUST SERVICE OR REPAIR HEREINAFTER SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL SHOULD SERVICE THE EQUIPMENT THE MANUFACTURE...

Страница 2: ...ck hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks during installa...

Страница 3: ...gloves Install drain piping to proper drainage Improper drain piping may result in water leakage and property damage Insulate piping to prevent condensation Be careful when transporting the product D...

Страница 4: ...conventional refrigerants gauge manifold charge hose gas leak detector reverse flow check valve refrigerant charge base vacuum gauge or refrigerant recovery equipment If the conventional refrigerant a...

Страница 5: ...ler Regarding wiring All wiring must be performed by an authorized electrician To do wiring ask your dealer Never do it by yourself Make sure that a separate power supply circuit is provided for this...

Страница 6: ...on is pressed continuously Used to change the selected item 6 Right Button Used to highlight items to the right of the currently selected item Display contents are changed to next screen per page 7 Le...

Страница 7: ...How to follow the operation manual Preparation For mechanical protection purposes apply power to the outdoor units at least six hours before starting the opeartion of the system Operation 1 Press the...

Страница 8: ...ystem automatically controls the following operating modes to prevent the reduction of heating capacity and space comfort Defrost Operation The system will automatically go into defrost operation to p...

Страница 9: ...y switch 6 hours before operation for smooth running Refer to MAINTENANCE When the display shows Time to clean filter ask a qualified service person to clean the filters Refer to MAINTENANCE 8 MAINTEN...

Страница 10: ...e time to clean filter and how to clean please refer to the attached manual HOW TO CLEAN THE AIR FILTER 1 Remove the air filter 2 Clean the air filter Please refer to attached manual Air filter is fie...

Страница 11: ...immediately after the ON OFF button is pressed If the OPERATION lamp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of t...

Страница 12: ...TING I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person If the air conditioner or heat...

Страница 13: ...if If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove the obstacle to ensure it is well ventilated If the air filter is clogged Ask a qualified service pers...

Страница 14: ...14 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 15: ...15 English THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 16: ...and drain pan tablets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum e...

Отзывы: