background image

1-16

FRONT

Recess on  

main unit

AIR FILTER

Open the front panel. 

 Hold the panel at the recesses on the main unit 
(2 recesses on right and left sides) and lift it until it 
stops.

1.

Clean or replace each filter.

 When shaking off remaining water, do not wring the 
filter.

3.

 Set the air filter as they were and close the front 
panel.

 Insert claws of the filters into slots of the front panel. 
Close the front panel slowly and push the panel at the 
3 points. (1 on each side and 1 in the middle.)
 The air filter have a symmetrical form in the horizontal 
direction.

4.

Pull out the air filters.

 Push a little upwards the tab at the center of each air 
filter, then pull it down.

2.

Rotating 

shaft

Recess on 

main unit

SERVICE AND MAINTENANCE

Open the front panel.

 Hold the panel at the recesses on the main unit 
(2 recesses on right and left sides) and lift it until it 
stops.

1.

Remove the front panel.

 While lifting the front panel further, slide it to the right 
and pull it to the front side. The left rotating shaft is 
detached. Slide the right rotating shaft to the left and 
pull it to the front side to remove it.

2.

Attach the front panel.

 Align the right and left rotating shafts of the front panel 
with the grooves and push them all the way in.
 Gently close the front panel. (Push both ends and the 
center on the front panel.)

3.

!

 

CAUTION

•   Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to deform as a result 

of chemical reaction.

Service Parts

Maintenance Procedures

Period

Indoor air filter

Remove any dust adhering to the filter by using a vacuum cleaner or wash in 
lukewarm water (below 40°C/104°F) with a neutral cleaning detergent.
Rinse the filter well and dry before placing it back onto the unit.
Do not use gasoline, volatile substances or chemicals to clean the filter.

1.

2.
3.

At least once 
every 2 weeks.
More frequently 
if necessary.

Indoor unit

Clean any dirt or dust on the grille or panel by wiping it with a soft cloth soaked 
in lukewarm water (below 40°C/104°F) and a neutral detergent solution.
Do not use gasoline, volatile substances or chemicals to clean the indoor unit.

1.

2.

At least once 
every 2 weeks.
More frequently 
if necessary.

1 IM-5WMJR-0515(0)-DAIKIN SIESTA16   16

1 IM-5WMJR-0515(0)-DAIKIN SIESTA16   16

6/1/15   3:20:44 PM

6/1/15   3:20:44 PM

Содержание Siesta ATYN20LV1

Страница 1: ...1 ATYN25LV1 ARYN25LV1 ATYN35LV1 ARYN35LV1 ATYN50LV1 ARYN50LV1 ATYN60LV1 ARYN60LV1 WALL MOUNTED R410A SPLIT TYPE AIR CONDITIONER IM 5WMJR 0515 0 DAIKIN SIESTA Part No R08019043338 Installation Manual R...

Страница 2: ......

Страница 3: ...WS INSIDE LOUVER SIGNAL RECEIVER INDOOR UNIT ON OFF SWITCH ROOM TEMPERATURE THERMISTOR INSIDE NAME PLATE TERMINAL BLOCK WITH EARTH TERMINAL F E J G G L D B K M A Gas pipe end INSTALLATION PLATE 20 25...

Страница 4: ...1065 310 224 190 173 61 40 45 48 91 219 580 45 Recommended mounting plate retention spots 7 spots in all Dimension Model A B C D E F G H I J K L M 20 25 35J 800 288 206 104 141 30 46 55 56 153 181 20...

Страница 5: ...C G H I J Dimension Model O P Q R S T 20C 22 3 19 65 80 30 25 35C 18 3 19 65 80 30 T All dimensions are in mm B A Q P R S D O K L L M N F E C G H I J N Dimension Model A B C D E F G H I J K L 50C 855...

Страница 6: ...om TVs and radios to prevent distorted pictures and static Depending on the type and source of the electrical waves static may be heard even when more than 1m away Please take note of the following im...

Страница 7: ...crews 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down INSTALLATION DIAGRAM Indoor unit Service lid Cut thermal insulation pipe to an appropriate length and wrap it...

Страница 8: ...age Please remove side plate when connecting the piping and connecting cord PUSH PULL UP BASE A DRAIN ELBOW DRAIN ELBOW PLUG INSTALLATION OF THE OUTDOOR UNIT The outdoor unit must be installed in such...

Страница 9: ...ace for performance Required space Right back piping All dimensions are in mm Right bottom piping Right side piping Remove pipe port cover here for right side piping Left back piping Left side piping...

Страница 10: ...or Unit Push up the marked area at the lower part of the front grille to release the claws Mounting plate Interconnecting wires Hang indoor unit s hook here Wire guide When stripping the ends of inter...

Страница 11: ...m 12 12 12 20 20 Max Allowable Elevation E m 5 5 5 15 15 Gas Pipe Size mm in 9 52 3 8 9 52 3 8 12 70 1 2 12 70 1 2 15 88 5 8 Liquid Pipe Size mm in 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 Heat P...

Страница 12: ...firmly on the swaging block Match the centers of both the swaging block and the flaring punch then tighten the flaring punch fully Piping Connection To The Units Align the center of the piping and tig...

Страница 13: ...Supply Cable Attach insulation sleeve Round crimp style terminal Electric wire All wires must be firmly connected All wires must not touch the refrigerant piping compressor or any moving parts of the...

Страница 14: ...pressor Remove the caps from the valve and the service port Connect the center of the charging gauge to the vacuum pump Connect the charging gauge to the service port of the 3 way valve Start the vacu...

Страница 15: ...h an auto mode sensor whereby it will provide reasonable room temperature by switching automatically to either cool or heat mode according to the temperature set by the user ON OFF Cool Heat Timer Sle...

Страница 16: ...1 time Room air sensor contact Loose Short Call your dealer Blink E1 3 times Outdoor coil sensor open Call your dealer Blink E3 2 times Indoor coil sensor open Call your dealer Blink E2 1 time Compre...

Страница 17: ...ulting in drippings Overheating Protection for heat pump unit only In case the internal and or the external temperature is too high or that the filter is dirty and clogged up the refrigerant may be ov...

Страница 18: ...ing shaft is detached Slide the right rotating shaft to the left and pull it to the front side to remove it 2 Attach the front panel Align the right and left rotating shafts of the front panel with th...

Страница 19: ...erature is not high enough Discharge air flow has bad odour 4 Odours may be caused by cigarettes smoke particles perfume etc which might have adhered onto the coil Condensation on the front air grille...

Страница 20: ...MEMO...

Страница 21: ...2 1 XEMA A MEP 20 25 35J 1 2 A B C D E F G H I J K L M 20 25 35J 800 288 206 166 184 42 46 55 56 154 182 263 52 K ATYN A B C H I B F E J G G L D B K M A 20 25 35J 65 F 5...

Страница 22: ...L M 20 25 35J 800 288 206 104 141 30 46 55 56 153 181 207 52 A B C D E F G H I J K L M 50 60J 1065 310 224 190 173 61 40 45 48 91 219 580 45 D B G H J L M A K F I G F E 50 60J 7 5 65 E F G I K M L J...

Страница 23: ...521 250 485 175 36 95 93 86 68 441 130 111 15 O P Q R S T 20C 22 3 19 65 80 30 25 35C 18 3 19 65 80 30 T B A Q P R S D O K L L M N F E C G H I J N A B C D E F G H I J K L 50C 855 628 328 520 179 46 9...

Страница 24: ...2 4 H MAH E CTOPO HO 1 1 OFF...

Страница 25: ...2 5 M4 x 12L e 75 50 1 2 3 500...

Страница 26: ...2 6 2 A A H A B C D acc o e 300 1000 300 500 A B H 2 H pe c C D pe c...

Страница 27: ...2 7 50 50 75 c y ox K K 50 60J 20 25 35J K 20 25 35J 20 25 35J 50 60J 65...

Страница 28: ...173 61 310 61 48 45 580 1065 219 40 40 91 45 65 166 184 181 7 55 5 54 5 153 8 263 51 9 800 45 9 42 2 288 42 2 45 9 poc ep e ec ep o 50 60J 20 25 35J 5 65 7 65 5 104 141 30 46 56 181 800 55 207 52 153...

Страница 29: ...2 9 7 5 ATYN 20J 25J 35J 50J 60J ARYN 20C 25C 35C 50C 60C M L 3 Ma L 12 12 12 20 20 E 5 5 5 15 15 9 52 3 8 9 52 3 8 12 70 1 2 12 70 1 2 15 88 5 8 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 L E...

Страница 30: ...2 3 8 42 31 0 12 70 1 2 55 40 6 15 88 5 8 65 48 0 19 05 3 4 78 57 6 C D A 1 4 6 35 1 3 0 7 3 8 9 52 1 6 1 0 1 2 12 70 1 9 1 3 5 8 15 88 2 2 1 7 3 4 19 05 2 5 2 0 II III IV L 3 8 OD9 52 0 18 1 3 1 2 OD...

Страница 31: ...2 11 N OF 4WV N1 L COMP N OF 4WV COMP ATYN 20J 25J 35J 50J 60J ARYN 20C 25C 35C 50C 60C 220 240V 50 2 1 5 3 2 5 3 2 1 5 5 2 5 5 A 15 20 8 N L2 L L1 3 H07RN F...

Страница 32: ...2 12 R410A R410A 1 6 R22 R410A POE PVE R410A R22 R410A POE PVE R22 R410A R410A R410A R22 C 3 30 760 760 3 2 4 o 3 760 760 3 3...

Страница 33: ...2 13 ATYN 20 25 35 50 60J ON OFF 7 5 7 5 1 2 1 ATYN35J ARYN35C 12 4 5 4 5 x 9 40 5 1 R410A ATYN 20J 25J 35J 50J 60J ARYN 20C 25C 35C 50C 60C 20 16 16 19 16...

Страница 34: ...2 14 1 E1 3 E3 2 E2 1 E4 3 E5 6 E8 4 E9...

Страница 35: ...2 15 2 C 3 6 F 2 C 3 6 F 2 C 3 6 F 62 C 143 6 F 1 C 33 8 F HIGH HOT KEEP OFF INTERVAL ON X DB WB WB C DB C 46 43 19 14 19 23 DB C 15 20 27 WB C 18 10 9...

Страница 36: ...2 16 FRONT 2 1 3 4 2 2 1 2 c 3 CTOPO HO 40 104 F 1 2 3 1 2 40 104 F 1 2 1 2...

Страница 37: ...2 17 CTOPO HO 40 C 3 1 3 4 2 3 4 5 6 2 30 C 86 F...

Страница 38: ......

Страница 39: ......

Страница 40: ...contain herein at any time without prior notification P O Box 18674 Galleries 4 11th Floor Downtown Jebel Ali Dubai UAE Zandvoordestraat 300 B 8400 Oostende Belgium Importer for Turkey Allianz Plaza K...

Отзывы: