• Split - Sky Air • Outdoor Unit

3

• Outdoor Unit • Outdoor units optimized for seasonal efficiency • RZQSG-LY1

2

Specifications

2-1 Nominal Capacity And Nominal Input

FCQHG100F/ RZQSG100LY1

FCQHG125F/ RZQSG125LY1

FCQHG140F/ RZQSG140LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.57

3.71

4.17

Heating

Nom.

kW

2.51

3.60

4.29

EER

3.70

3.23

3.21

COP

4.30

3.75

3.61

SEER

5.70 (6)

5.21 (6)

-

SCOP

3.91 (6)

3.81 (6)

-

Annual energy consumption

kWh

1,285

1,855

2,085

Energy label

Cooling

A

Heating

A

2-1 Nominal Capacity And Nominal Input

FCQG100F / RZQSG100LY1

FCQG125F / RZQSG125LY1

FCQG140F / RZQSG140LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.88

3.74

4.45

Heating

Nom.

kW

3.05

3.96

4.54

EER

3.30

3.21

3.01

COP

3.54

3.41

SEER

5.11 (6)

-

SCOP

3.80 (6)

3.81 (6)

-

Annual energy consumption

kWh

1,440

1,870

2,225

Energy label

Cooling

A

B

Heating

A

B

2-1 Nominal Capacity And Nominal Input

FAQ100C / RZQSG100LY1

Cooling capacity

Nom.

kW

9.5 (3)

Heating capacity

Nom.

kW

10.8 (4)

Power input

Cooling

Nom.

kW

3.16

Heating

Nom.

kW

3.17

EER

3.01

COP

3.41

SEER

4.61 (6)

SCOP

3.81 (6)

Annual energy consumption

kWh

1,580

Energy label

Cooling

B

Heating

B

2-1 Nominal Capacity And Nominal Input

FVQ100C / RZQSG100LY1

FVQ125C / RZQSG125LY1

FVQ140C / RZQSG140LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.96

4.27

4.45

Heating

Nom.

kW

2.99

3.96

4.54

EER

3.21

2.81

3.01

COP

3.61

3.41

SEER

5.11 (6)

4.31 (6)

-

SCOP

3.80 (6)

3.81 (6)

-

Annual energy consumption

kWh

1,480

2,135

2,225

Energy label

Cooling

A

B

Heating

A

B

Содержание RZQSG125LY1

Страница 1: ...RZQSG LY1 Technical Data E E D E N 1 2 1 0 0 O u t d o o r u n i t s o p t i m i z e d f o r s e a s o n a l e f f i c i e n c y Air Conditioners...

Страница 2: ...bles 11 Heating Capacity Tables 14 Capacity Correction Factor 17 7 Dimensional drawings 18 Dimensional Drawings 18 8 Centre of gravity 19 Centre of Gravity 19 9 Piping diagrams 20 Piping Diagrams 20 P...

Страница 3: ...ives an indication on how efficient an air conditioner operates over an entire heating or cooling season Re use of existing R 22 or R 407C technology The use of inverter type outdoor units results in...

Страница 4: ...4 15 5 4 Power input Cooling Nom kW 2 88 3 74 4 45 Heating Nom kW 3 05 3 96 4 54 EER 3 30 3 21 3 01 COP 3 54 3 41 SEER 5 11 6 SCOP 3 80 6 3 81 6 Annual energy consumption kWh 1 440 1 870 2 225 Energy...

Страница 5: ...Heating capacity Nom kW 10 8 4 13 5 4 15 5 4 Power input Cooling Nom kW 2 87 3 74 4 44 Heating Nom kW 2 96 3 85 4 54 EER 3 31 3 21 3 02 COP 3 65 3 51 3 41 SEER 5 11 6 4 35 6 SCOP 3 81 6 Annual energy...

Страница 6: ...Anti corrosion treatment PE Fan Type Propeller fan Discharge direction Horizontal Quantity 1 2 Air flow rate Cooling Nom m min 76 77 83 Super low m min cfm Heating Nom m min 83 62 Super low m min cfm...

Страница 7: ...ctions Liquid Quantity 1 Type Flare connection OD mm 9 52 Gas Quantity 1 Type Flare connection OD mm 15 9 Drain Quantity 5 Type Hole ID mm OD mm 26 Piping length OU IU Min m 5 Max m 50 System Equiva l...

Страница 8: ...3 1 3 Split Sky Air Outdoor Unit 7 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 3 Electrical data 3 1 Electrical Data...

Страница 9: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 3 Split Sky Air Outdoor Unit 8 3 Electrical data 3 1 Electrical Data...

Страница 10: ...3 1 4 Split Sky Air Outdoor Unit 9 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 4 Options 4 1 Options...

Страница 11: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 5 Split Sky Air Outdoor Unit 10 5 Combination table 5 1 Combination Table...

Страница 12: ...3 1 6 Split Sky Air Outdoor Unit 11 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 6 Capacity tables 6 1 Cooling Capacity Tables...

Страница 13: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 6 Split Sky Air Outdoor Unit 12 6 Capacity tables 6 1 Cooling Capacity Tables...

Страница 14: ...3 1 6 Split Sky Air Outdoor Unit 13 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 6 Capacity tables 6 1 Cooling Capacity Tables...

Страница 15: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 6 Split Sky Air Outdoor Unit 14 6 Capacity tables 6 2 Heating Capacity Tables...

Страница 16: ...3 1 6 Split Sky Air Outdoor Unit 15 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 6 Capacity tables 6 2 Heating Capacity Tables...

Страница 17: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 6 Split Sky Air Outdoor Unit 16 6 Capacity tables 6 2 Heating Capacity Tables...

Страница 18: ...3 1 6 Split Sky Air Outdoor Unit 17 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 6 Capacity tables 6 3 Capacity Correction Factor...

Страница 19: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 7 Split Sky Air Outdoor Unit 18 7 Dimensional drawings 7 1 Dimensional Drawings...

Страница 20: ...3 1 8 Split Sky Air Outdoor Unit 19 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 8 Centre of gravity 8 1 Centre of Gravity...

Страница 21: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 9 Split Sky Air Outdoor Unit 20 9 Piping diagrams 9 1 Piping Diagrams...

Страница 22: ...3 1 9 Split Sky Air Outdoor Unit 21 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 9 Piping diagrams 9 2 Piping Diagram Twin Application...

Страница 23: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 9 Split Sky Air Outdoor Unit 22 9 Piping diagrams 9 3 Piping Diagram Triple Application...

Страница 24: ...3 1 9 Split Sky Air Outdoor Unit 23 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 9 Piping diagrams 9 4 Piping Diagram Double Twin Application...

Страница 25: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 10 Split Sky Air Outdoor Unit 24 10 Wiring diagrams 10 1 Wiring Diagrams Three Phase...

Страница 26: ...3 1 11 Split Sky Air Outdoor Unit 25 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 11 Sound data 11 1 Sound Power Spectrum...

Страница 27: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 11 Split Sky Air Outdoor Unit 26 11 Sound data 11 2 Sound Pressure Spectrum Cooling...

Страница 28: ...3 1 11 Split Sky Air Outdoor Unit 27 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 11 Sound data 11 3 Sound Pressure Spectrum Heating...

Страница 29: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 11 Split Sky Air Outdoor Unit 28 11 Sound data 11 4 Sound Pressure Spectrum Quiet Mode...

Страница 30: ...3 1 12 Split Sky Air Outdoor Unit 29 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 12 Installation 12 1 Installation Method...

Страница 31: ...Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 1 12 Split Sky Air Outdoor Unit 30 12 Installation 12 1 Installation Method...

Страница 32: ...3 1 13 Split Sky Air Outdoor Unit 31 Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG LY1 13 Operation range 13 1 Operation Range...

Страница 33: ...ted by Daikin Europe N V Daikin s unique position as a manufacturer of air conditioning equipment compressors and refrigerants has led to its close involvement in environmental issues For several year...

Отзывы: