background image

3P362438-1B English

i

Safety considerations

Read these Safety considerations for Installation carefully be-
fore installing an air conditioner or heat pump. After complet-
ing the installation, make sure that the unit operates properly 
during the startup operation.
Instruct the customer on how to operate and maintain the 
unit.
Inform customers that they should store this Installation 
Manual with the Operation Manual for future reference.
Always use a licensed installer or contractor to install this 
product.
Improper installation can result in water or refrigerant leak-

age, electrical shock, fire, or explosion.

Meanings of 

DANGER

WARNING

CAUTION

, and 

NOTE

Symbols:

DANGER   .  .  .  .  .  .  .  .

Indicates an imminently hazardous 
situation which, if not avoided, will 
result in death or serious injury.

WARNING   .  .  .  .  .  .  .

Indicates a potentially hazardous 
situation which, if not avoided, 
could result in death or serious 
injury.

CAUTION  .  .  .  .  .  .  .  .

Indicates a potentially hazardous 
situation which, if not avoided, 
may result in minor or moderate 
injury. It may also be used to alert 
against unsafe practices.

NOTE   .  .  .  .  .  .  .  .  .  .  .

Indicates situations that may result 
in equipment or property-damage 
accidents only.

INFORMATION   .  .  .

This symbol identifies useful tips 

or additional information.

 DANGER

•  Refrigerant gas is heavier than air and replaces oxygen. A 

massive leak will result in oxygen depletion, especially in 
basements, and an asphyxiation hazard will result in seri

-

ous injury or death.

• 

Do not ground units to water pipes, gas pipes, telephone 
wires, or lightning rods as incomplete grounding will result 
a severe shock hazard resulting in severe injury or death. 
Additionally, grounding to gas pipes will result a gas leak 

and potential explosion resulting in severe injury or death.

• 

If refrigerant gas leaks during installation, ventilate the 
area immediately. Refrigerant gas will result in producing 

toxic gas if it comes into contact with fire. Exposure to this 

gas will result in severe injury or death.

• 

After completing the installation work, check that the re-
frigerant gas does not leak throughout the system.

•  Do not install unit in an area where flammable materials 

are present due to risk of explosions that will result in seri

-

ous injury or death.

• 

Safely dispose all packing and transportation materials 
in accordance with federal/state/local laws or ordinances. 
Packing materials such as nails and other metal or wood 
parts, including plastic packing materials used for trans-
portation will result in injuries or death by suffocation.

 WARNING

•  Only qualified personnel must carry out the installation 

work. Installation must be done in accordance with this 
installation manual. Improper installation could result in 

water leakage, electric shock, or fire.

• 

When installing the unit in a small room, take measures to 

keep the refrigerant concentration from exceeding allow

-

able safety limits. Excessive refrigerant leaks, in the event 

of an accident in a closed ambient space, could result in 

oxygen deficiency.

•  Use only specified accessories and parts for installation 

work. Failure to use specified parts could result in water 
leakage, electric shocks, fire, or the unit falling.

• 

Install the air conditioner or heat pump on a foundation 
strong enough that it can withstand the weight of the unit. 

A foundation of insufficient strength could result in the unit 

falling and causing injuries.

• 

Take into account strong winds, typhoons, or earthquakes 
when installing. Improper installation could result in the 
unit falling and causing accidents.

• 

Make sure that a separate power supply circuit is pro-
vided for this unit and that all electrical work is carried 

out by qualified personnel according to local, state and 
national regulations. An insufficient power supply capacity 

or improper electrical construction could result in electric 

shocks or fire.

•  Make sure that all wiring is secured, that specified wires 

are used, and that no external forces act on the terminal 

connections or wires. Improper connections or installation 

could result in fire.

•  When wiring, position the wires so that the control box 

cover can be securely fastened. Improper positioning of 

the control box cover could result in electric shocks, fire, or 

the terminals overheating.

• 

Before touching electrical parts, turn off the unit. 

• 

This equipment can be installed with a Ground-Fault Cir-
cuit Breaker (GFCI). Although this is a recognized mea-
sure for additional protection, with the grounding system in 
North America, a dedicated GFCI is not necessary.

• 

Securely fasten the unit terminal cover (panel). If the 
terminal cover/panel is not installed properly, dust or 

water may enter the outdoor unit and could result in fire or 

electric shock.

• 

When installing or relocating the system, keep the refriger-

ant circuit free from substances other than the specified 

refrigerant (R410A) such as air. Any presence of air or oth-
er foreign substance in the refrigerant circuit could result 
in abnormal pressure rise or rupture, resulting in injury.

• 

Do not change the setting of the protection devices. If the 
pressure switch, thermal switch, or other protection device 
is shorted and operated forcibly, or parts other than those 

specified by Daikin are used, fire or explosion could result.

Содержание RXYQ120TTJU

Страница 1: ...RXYQ216TTJU RXYQ240TTJU RXYQ264TTJU RXYQ288TTJU RXYQ312TTJU RXYQ336TTJU RXYQ360TTJU RXYQ384TTJU RXYQ408TTJU RXYQ72TYDN RXYQ96TYDN RXYQ120TYDN RXYQ144TYDN RXYQ168TYDN RXYQ192TYDN RXYQ216TYDN RXYQ240TYD...

Страница 2: ...RNING Only qualified personnel must carry out the installation work Installation must be done in accordance with this installation manual Improper installation could result in water leakage electric s...

Страница 3: ...away from fluorescent lamps as much as possible Indoor units are for indoor installation only Outdoor units can be installed either outdoors or indoors This unit is for indoor use Do not install the a...

Страница 4: ...piping material 9 7 3 Selection of piping size 9 7 4 Selection of refrigerant branch kits 10 7 5 System piping length limitations 11 8 Precautions on refrigerant piping 14 8 1 Caution for brazing 14 8...

Страница 5: ...unit combinations Standard combinations for VRV IV heat pump system are as indicated in table below where RXYQ192 408 consists of several RXYQ72 168 modules as indicated 72 96 120 144 168 RXYQ72TTJU T...

Страница 6: ...following accessories are included The storage location of the accessories is shown in the figure below Accessories assy piping Accessories assy operation and installation manual NOTE Do not throw aw...

Страница 7: ...e reasonable protection against such interference However there is no guarantee that inter ference will not occur in a particular installation It is therefore recommended to install the equipment and...

Страница 8: ...nopy 2 Construct a pedestal NOTE When operating the unit in a low outdoor ambient temperature with high humidity conditions make sure to take precautions to keep the drainholes of the unit free by usi...

Страница 9: ...a Front side Suction side b h2 2 or more Service space h1 2 or more h1 b a 59 in 1500 mm b 19 5 8 in 500 mm In case of an installation site where sides A B C D have obsta cles the wall heights of sid...

Страница 10: ...ling of 3 4 in 20 mm wide that adequately bears the weight of the unit A forklift can only be used for transport as long as the unit remains on its pallet as shown above 6 3 Unpacking CAUTION To avoid...

Страница 11: ...oundation surface A A 13 16 in 20 mm NOTE There are restrictions on the refrigerant pipe connecting order between outdoor unit in the case of the multi system See 1 2 2 Outdoor unit combinations on pa...

Страница 12: ...t size Thickness Select a thickness for the refrigerant piping which complies with national and local laws For piping work follow the maximum tolerated length difference in height and length after a b...

Страница 13: ...se 4 First refrigerant branch kit 5 Indoor unit Size up for equivalent length for outdoor indoor units over 295 ft 90 m Outdoor unit capacity type Gas pipe Liquid pipe RXYQ72T type 3 4 in 19 1 mm 7 8...

Страница 14: ...gth allowable height difference and al lowable length after branching as indicated below 3 patterns will be discussed including VRV indoor units combined with Mini split indoor units Definitions Actua...

Страница 15: ...ple 1 3 unit 8 a i 540 ft 165 m Equivalent length 2 623 ft 190 m Total piping length 3280 ft 1000 m Example 1 1 a b c d e f g h i j k l m n p 3280 ft 1000 m Example 2 1 a b c d e f g h i j k l m n p 3...

Страница 16: ...een the nearest indoor from the first branch to the outdoor unit and farthest indoor to the outdoor unit is 130 ft 40 m Example The farthest indoor unit 8 The nearest indoor unit 1 a b c d e f g p a h...

Страница 17: ...brazing Blowing through with Dry Nitrogen prevents the creation of large quantities of oxidized film on the inside of the piping An oxidized film ad versely affects valves and compressors in the refri...

Страница 18: ...ective plate Stop valve mounting plate 5 Cut off the lower part of the smaller pinched piping with an ap propriate tool such as pipe cutters Let the remaining oil drip out in case the recovery was not...

Страница 19: ...tween outdoor units an optional multi con nection piping kit BHFP22P100U 151U is always required When installing the piping follow the instructions in the installation manual that comes with the kit O...

Страница 20: ...so that it branches horizontally Installation of the multi connection piping kit A 1 max 15 B 1 C D C 4 3 4 in 120 mm D 19 11 16 in 500 mm 3 Install the joints horizontally so that the caution label...

Страница 21: ...field wiring and components must be installed by a licensed elec trician and must comply with relevant local and national regulations Be sure to use a dedicated power circuit Never use a power supply...

Страница 22: ...V 460 V 460 V 460 V 460 V 460 V 460 V 27 6A 36 3A 36 3A 55 1A 55 1A 27 6A 36 3A 36 3A 36 3A 36 3A 36 3A 36 3A 55 1A 55 1A 55 1A 55 1A 55 1A 55 1A 55 1A 36 3A 36 3A 36 3A 36 3A 36 3A 55 1A 36 3A 55 1A...

Страница 23: ...o an indoor unit is Master unit of the multi system The other units are Sub units In this figure Outdoor unit A is the Master unit Check installation work to ensure proper operation Onsite settings ca...

Страница 24: ...Ground terminal 10 Clamp 1 accessory 11 Vinyl tube accessory CAUTION Be sure to use crimp style terminal with insulating sleeves for con nections See the figure below Crimp style terminal Insulating...

Страница 25: ...after the stop valve is opened will cause the insulation value to drop Needed tools Gauge manifold Charge hose valve To prevent entry of any impurities and insure sufficient pressure resistance always...

Страница 26: ...insulate the pipes may cause leaking or burns Be sure to use insulation designed for HVAC equipment Reinforce the insulation on the refrigerant piping according to the installation environment Conden...

Страница 27: ...elow procedure explains how to operate the push buttons to reach the required mode in the menu select the correct setting and modify the value of the setting This procedure can be used any time specia...

Страница 28: ...elected push BS1 for more than 5 seconds you can select the wanted setting It is done by pushing BS2 Accessing the selected setting s value is done by pushing BS3 one time Now BS2 is used to select th...

Страница 29: ...itional refrigerant to be charged Additional refrigerant to be charged R lbs R should be rounded off in units of 0 1 lbs R X1 f7 8 0 249 X2 f3 4 0 175 X3 f5 8 0 121 X4 f1 2 0 081 X5 f3 8 0 040 X6 f1 4...

Страница 30: ...on on page 38 R Q You want to execute automatic refrigerant charge B A Step 4b 5 Manual refrigerant charging method in cooling operation NO YES Step 4b 5 Automatic refrigerant charging method Step 6B...

Страница 31: ...38 During gray conditions If following codes appear E 2 indoor temperature out of range and E 3 outdoor temperature out of range In this case perform automatic charg ing procedure again See figure Loc...

Страница 32: ...low chart is available which gives an overview of the possibilities and actions to be taken see 14 3 1 Flow chart on page 27 To speed up the process of pre charging refrigerant for large systems it is...

Страница 33: ...st run If the unit indicates E 2 or E 3 the ambient conditions are NOT favorable to execute the test run Push BS1 to finish the automatic charging procedure INFORMATION In case a malfunction code occu...

Страница 34: ...gauge lines Connect service gauge manifold to the service port between the compressor and the reversing valve in each outdoor unit Run the system for 30 minutes in cooling by the forced operation usi...

Страница 35: ...C configuration software Below relevant Monitoring mode mode 1 and Field setting mode mode 2 settings are explained in detail How to access them how to change the value of the settings and how to conf...

Страница 36: ...ool Heat selection setting is used in case the optional Cool Heat selector KRC19 26A is used Depending on the outdoor unit setup single outdoor unit setup or multi outdoor unit setup the correct setti...

Страница 37: ...or 3 2 26 Low noise operation start time Change 2 26 1 2 or 3 in function of required timing Default value 2 Value 2 26 Start time automatic low noise operation approximately 1 8 00 p m 2 10 00 p m de...

Страница 38: ...rt setting Default value 1 Value 2 82 Heating comfort setting 0 Eco 1 Mild default 2 Quick 3 Powerful Change 2 82 0 1 2 or 3 in function of required limitation This setting is used in conjunction with...

Страница 39: ...ting opera tion change field setting 2 82 3 This setting is used in conjunction with setting 2 9 Quick Overshoot during heating operation or undershoot during cooling operation is allowed compared to...

Страница 40: ...perature evolution A B C D E F A Indoor unit set temperature B Operation start C Operating time D Mild E Quick F Powerful Example Automatic mode during cooling A B 100 70 E Tc C D 120 F 49 C F 115 F 4...

Страница 41: ...RMATION Note that during the first running period of the unit required power in put may be higher This phenomenon originates from the compressor that requires a 50 hour run elapse before reaching smoo...

Страница 42: ...ction code table After correcting the abnormality press BS3 to reset the malfunction code and retry operation The malfunction code which is displayed on the outdoor unit will indi cate a main malfunct...

Страница 43: ...c tion R6T A1P X30A Check connection on printed circuit board or actuator JA 06 08 10 High pressure sensor malfunction S1NPH open circuit A1P X32A Check connection on printed circuit board or actuator...

Страница 44: ...02 Faulty wiring to Q1 Q2 or indoor outdoor Connect transmission wiring of indoor unit to TO IN D UNIT F1 F2 and transmission wiring of other outdoor unit to TO OUT D UNIT F1 F2 11 Too many indoor un...

Страница 45: ...e i CAUTION When performing service to inverter equipment 1 Do not open the control box cover for 10 minutes after the power supply is turned off 2 Measure the voltage between terminals on the termina...

Страница 46: ...y large This assures that the maximum concentration level of refrigerant gas is not exceeded in the unlikely event of major leak in the system and this in accordance to the local applicable regulation...

Страница 47: ......

Страница 48: ......

Страница 49: ...3P362438 1B EM13A019A 1402 FS...

Отзывы: