3
|
Components
Service manual
60
RXQ25+3 3 3
35AMV1B
Split Sensira R32 BBOP
ESIE21-16 – 2022.02
CAUTION
Overheating the compressor pipes (and the oil inside the compressor pipes) will
damage or destroy the compressor.
9
After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
10
Install the compressor thermal protector, see
11
Connect the Faston connectors to the compressor wire terminals U, V and W
V
U
W
U
Wire terminal U
V
Wire terminal V
W
Wire terminal W
12
Install the cover of the compressor wire terminals.
a
a
Compressor wire terminals cover
13
Install the compressor insulation, see
14
15
Add
refrigerant
to
the
refrigerant
circuit,
see