Contents

Safety Considerations   ....................................  1
Accessories   .....................................................  3
Precautions for Selecting a Location   ...........  3
Precautions on Installation   ............................  4
Outdoor Unit Installation Diagram   ................  4
Installation Space Requirements   ..................  5
Outdoor Unit Installation   ................................  5

1.  Installing the outdoor unit ............................................ 5
2.  Drain work ................................................................... 5
3.  Flaring the pipe end ..................................................... 6

4.  Refrigerant piping ........................................................ 6
5.  Pressure test and evacuating system .......................... 7

6.  Refilling refrigerant

 ...................................................... 8

Wiring   ...............................................................  9
Facility Setting  
(cooling at low outdoor temperature)   ...........  10
When Attaching the Drain Pan Heater   ..........  11
Pump Down Operation   ...................................  12
Trial Operation and Testing   ...........................  13

1.  Trial operation and testing ........................................... 13
2.  Test items .................................................................... 13

Safety Considerations

Refer also to the General Safety Considerations in the 

separate booklet.

Read the precautions in this manual 
carefully before operating the unit.

Read these 

Safety Considerations for Installation carefully 

before installing an air conditioner or heat pump. After completing 

the installation, make sure that the unit operates properly during 

the startup operation.

Instruct the user on how to operate and maintain the unit.

Inform users that they should store this installation manual with 

the operation manual for future reference.

Always use a licensed installer or contractor to install this product.

Improper installation can result in water or refrigerant leakage, 

electric shock, fire, or explosion. 

Meanings of 

DANGERWARNINGCAUTION, and NOTE 

Symbols:

 DANGER  ...........

Indicates an imminently hazardous 

situation which, if not avoided, will 

result in death or serious injury.

 WARNING  .........

Indicates a potentially hazardous 

situation which, if not avoided, could 

result in death or serious injury.

 CAUTION  ..........

Indicates a potentially hazardous 

situation which, if not avoided, may 

result in minor or moderate injury. 

It may also be used to alert against 

unsafe practices.

 NOTE  ................

Indicates situations that may result 

in equipment or property damage 

accidents only.

DANGER 

• 

Refrigerant gas is heavier than air and replaces oxygen. 

A massive leak can lead to oxygen depletion, especially 

in basements, and an asphyxiation hazard could occur 

leading to serious injury or death.

•  Do not ground units to water pipes, gas pipes, telephone 

wires, or lightning rods as incomplete grounding can cause 

a severe shock hazard resulting in severe injury or death. 

Additionally, grounding to gas pipes could cause a gas leak 

and potential explosion causing severe injury or death.

•  If refrigerant gas leaks during installation, ventilate the 

area immediately. Refrigerant gas may produce toxic gas 

if it comes into contact with fire. Exposure to this gas could 

cause severe injury or death.

•  After completing the installation work, check that the 

refrigerant gas does not leak throughout the system.

• 

Do not install unit in an area where flammable materials 

are present due to risk of explosions that can cause 

serious injury or death.

•  Safely dispose all packing and transportation materials 

in accordance with federal/state/local laws or ordinances. 

Packing materials such as nails and other metal or 

wood parts, including plastic packing materials used for 

transportation may cause injury or death by suffocation.

WARNING 

• 

Only qualified personnel licensed or certified in their 

jurisdiction must carry out the installation work. Installation 

must be done in accordance with this installation manual. 

Improper installation may result in water leakage, electric 

shock, or fire.

•  When installing the unit in a small room, take measures 

to keep the refrigerant concentration from exceeding 

allowable safety limits. Excessive refrigerant leaks, in the 

event of an accident in a closed ambient space, can lead 

to oxygen deficiency.

• 

Use only specified accessories and parts for installation 

work. Failure to use specified parts may result in water 

leakage, electric shock, fire, or the unit falling.

•  Install the air conditioner or heat pump on a foundation 

strong enough that it can withstand the weight of the unit. 

A foundation of insufficient strength may result in the unit 

falling and causing injury.

•  Take into account strong winds, typhoons, or earthquakes 

when installing. Improper installation may result in the unit 

falling and causing accidents.

•  Make sure that a separate power supply circuit is provided 

for this unit and that all electrical work is carried out by 

qualified personnel licensed or certified in their jurisdiction 

according to local, state, and national regulations. An 

insufficient power supply capacity or improper electrical 

construction may lead to electric shock or fire.

The pictures in this document are for illustrative purposes only.

01_EN_3P686855-1.indd   1

2022/05/16   9:29:36

Содержание RX09WMVJU9

Страница 1: ...ODELS RX09WMVJU9 RX12WMVJU9 RXL09WMVJU9 RXL12WMVJU9 DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Installation manual Manuel d installation Manual de instalaci n 00_CV_3P686855 1...

Страница 2: ...severe shock hazard resulting in severe injury or death Additionally grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death If refrigerant gas leaks duri...

Страница 3: ...UNISO oil or moisture should be prevented from getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again har...

Страница 4: ...w from the drain of the outdoor unit do not place anything under the unit which must be kept away from moisture 9 A location where flammable gas does not leak Position at least 6 5 8ft 2m from propane...

Страница 5: ...nt in which it is used Foot bolt hole centers 18 1 2 470 From unit s side 3 13 16 97 Footbolt hole centers 12 1 8 308 O D 3 8 inch 9 5mm Gas pipe Liquid pipe O D 1 4 inch 6 4mm 0 21oz ft 20g m Max all...

Страница 6: ...tion of the outdoor unit outlet side or use the air direction adjustment grille sold separately More than 3 15 16 100 More than 13 3 4 150 Outdoor Unit Installation 1 Installing the outdoor unit When...

Страница 7: ...igid type 0 059 0 079 inch 1 5 2 0mm Wing nut type Imperial type Conventional are tool Cut exactly at right angles Remove burrs 4 Refrigerant piping CAUTION Use the flare nut fixed to the main unit Th...

Страница 8: ...16 13 32 inch 8 10mm 13 32 inch 10mm Min Minimum bend radius Piping thickness Thermal insulation size Thermal insulation thickness Liquid side Use separate thermal insulation pipes for gas and liquid...

Страница 9: ...id stop valve turn the rod of the valve 90 counter clockwise using a hexagonal wrench Close it after 5 seconds and check for gas leakage Using soapy water check for gas leakage from the indoor unit s...

Страница 10: ...for connection to the power supply terminal block Place the round crimp style terminals on the wires up to the covered part and secure in place Round crimp style terminal Stranded wire Screw Flat wash...

Страница 11: ...Conduit Lock nut Conduit mounting plate L1 L2 Ground This air conditioner must be grounded For grounding follow all local and state electrical codes Facility Setting cooling at low outdoor temperature...

Страница 12: ...is level 1 Remove the top plate of the outdoor unit 4 screws 2 Remove the front plate 5 screws 3 Cut the jumper J6 of the PCB inside Cut the jumper J6 For RX09 12 RXL09 Cut the jumper J6 For RXL12 J6...

Страница 13: ...nd FVX models 1 Press and at the same time 2 Press select and press for confirmation 3 Press and select the COOL operation 4 Press to turn on the system Forced cooling operation will stop automaticall...

Страница 14: ...ncomplete cooling heating function Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated Water leakage Draining line is properly installed Water leakage System is pr...

Страница 15: ...14 English MEMO English 01_EN_3P686855 1 indd 14 2022 05 16 9 29 40...

Страница 16: ...Two dimensional bar code is a manufacturing code 3P686855 1 M21B526 2205 HT 00_CV_3P686855 1 indd 2 2022 02 16 15 37 40...