5 Configuration
Installation manual
13
RHYHBH RHYHBH/X08AAV3
ROTEX HPU hybrid heat pump module
4P353065-1 – 2013.05
7LPH
:KDWLVWKHFXUUHQWWLPH"
&RQILUP
$GMXVW
6FUROO
3
Set the system layout settings: Standard, Options, Capacities.
For more details, see
"5.1.2 Basic configuration" on page 13
.
6\VWHPOD\RXW
6HOHFW
2SWLRQV
6FUROO
&DSDFLWLHV
$
&RQILUPOD\RXW
6WDQGDUG
4
Confirm by pressing
.
&RQILUPOD\RXW
3OHDVHFRQILUPWKHV\VWHP
OD\RXW7KHV\VWHPZLOO
2.
UHVWDUWDQGZLOOEHUHDG\IRU
&DQFHO
ILUVWVWDUWXS
&RQILUP
$GMXVW
5
The user interface re-initialises and you can proceed the
installation by setting the other applicable settings and
commissioning of the system.
When the installer settings are changed, the system will request to
confirm. When confirmation is complete, the screen will shortly turn
OFF and "busy" will be displayed for several seconds.
5.1.2
Basic configuration
Quick wizard: Language / time and date
#
Code
Description
[A.1]
N/A
Language
[1]
N/A
Time and date
Quick wizard: Standard
Space heating/cooling settings
#
Code
Description
[A.2.1.7]
[C-07]
Unit temperature control:
▪
0 (LWT control): Unit operation is
decided based on the leaving water
temperature.
▪
1 (Ext RT control): Unit operation is
decided by the external thermostat.
▪
2 (RT control): Unit operation is
decided based on the ambient
temperature of the user interface.
[A.2.1.B]
N/A
Only if there are 2 user interfaces:
User interface location:
▪
At unit
▪
In room
[A.2.1.8]
[7-02]
Number of water temperature zones:
▪
0 (1 LWT zone): Main
▪
1 (2 LWT zones): Main + additional
#
Code
Description
[A.2.1.9]
[F-0D]
Pump operation:
▪
0 (Continuous): Continuous pump
operation, regardless of thermo ON or
OFF condition.
▪
1 (Sample): When thermo OFF
condition occurs, the pump runs every
5 minutes and the water temperature
is checked. If the water temperature is
below target, unit operation can start.
▪
2 (Request): Pump operation based
on request. Example: Using a room
thermostat and thermostat creates
thermo ON/OFF condition.
Quick wizard: Options
Domestic hot water settings
#
Code
Description
[A.2.2.1]
[E-05]
Domestic hot water preparation:
▪
0 (No): NOT possible
▪
1 (Yes)(default): Possible
[A.2.2.2]
[E-06]
Domestic hot water production:
▪
0 (Type 1): by boiler
▪
1 (Type 2): by tank
[A.2.2.A]
[D-02]
Domestic hot water pump:
In case of [E-06]=0
▪
0 (No)(default): NOT installed
In case of [E-06]=1
▪
0 (No)(default): NOT installed
▪
1 (Secondary rtrn): Installed for instant
hot water
▪
2 (Disinf. shunt): Installed for
disinfection
See also illustrations below.
In case of [E-06]=1
Domestic hot water pump installed for…
Instant hot water
Disinfection
c
f
b
a
g
c
b
a
d
f
e
g
a
Indoor unit
b
Tank
c
Domestic hot water pump
d
Heater element
e
Non-return valve
f
Shower
g
Cold water