Si001405EB
Electrical Box
Removal Procedure
7
4
Disconnect the
connector [S40].
[S40]: overload protector
5
Disconnect the
connector [S90].
[S90]: thermistors
6
Cut the clamp.
7
Disconnect the relay
connector for the
compressor.
Step
Procedure
Points
[S40]
(R20228)
[S90]
(R20229)
(R20230)
Clamp
Relay connector
for compressor