Outdoor Fan / Fan Motor
Si001405EB
4
Removal Procedure
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Cut the clamp.
2
Disconnect the
connector [S79].
[S79]: fan motor
3
Release the fan motor
lead wire from the 2
slits and the 4 hooks on
the electrical box.
(R23690)
Clamp
[S79]
(R20224)
(R20429)
Hook