Safety Precautions

• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.

Be sure to follow all the precautions below: they are all important for ensuring safety.

WARNING...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

CAUTION .............. Failure to follow any of CAUTION may result in grave consequences in some cases.

• The following safety symbols are used throughout this manual: 

• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air 

conditioner and take care of it with the aid of the operation manual.

• The original instructions are written in English. Other languages are translations of the original instructions. 

Be sure to observe this instruction.

Be sure to establish an earth connection.

Never attempt.

WARNING

• Ask your dealer or qualified personnel to carry out installation work. 

Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire. 

• Install the air conditioner in accordance with the instructions in this installation manual. 

Improper installation may result in water leakage, electric shocks or fire. 

• Make sure installation, servicing, maintenance and repair comply with instruction from Daikin and with applicable 

legislation (for example national gas regulation) and are executed only by authorised persons.

• Be sure to use only the specified accessories and parts for installation work. 

Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire. 

• Install the air conditioner on a foundation strong enough to withstand the weight of the unit. 

A foundation of insufficient strength may result in the equipment falling and causing injury. 

• Electrical work must be performed in accordance with relevant local and national regulations and with instructions 

in this installation manual. Be sure to use a dedicated power supply circuit only. 

Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire. 

• Use a cable of suitable length. 

Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire. 

• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal 

connections or wires. 

Improper connections or securing of wires may result in abnormal heat build-up or fire. 

• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires 

so that the control box lid can be securely fastened. 

Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals. 

• If the supply cord is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified 

persons in order to avoid a hazard.

• If refrigerant gas leaks during installation, ventilate the area immediately. 

Toxic gas may be produced if the refrigerant comes into contact with fire. 

• After completing installation, check for refrigerant gas leakage.  

Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, 
stove or cooker. 

• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, 

and use only the specified refrigerant.

The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage 
and even injury. 

• During installation, attach the refrigerant piping securely before running the compressor. 

If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal 
pressure in the refrigeration cycle, which may result in equipment damage and even injury. 

• During pump-down, stop the compressor before removing the refrigerant piping. 

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, 
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. 

• Be sure to earth the air conditioner. 

Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks. 

• Be sure to install an earth leakage breaker. 

Failure to install an earth leakage breaker may result in electric shocks or fire. 

Read the precautions in this manual 
carefully before operating the unit.

Models FVXM are filled with R32.

3PEN477070-1F.book  Page 1  Thursday, March 28, 2019  9:06 AM

Содержание R32 Split Series

Страница 1: ...INSTALLATION MANUAL R32 Split Series Models FVXM25FV1B9 FVXM35FV1B9 FVXM50FV1B9 3PEN477070 1F book Page 1 Thursday March 28 2019 9 06 AM ...

Страница 2: ...mo estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A och godkänts av B enligt Certifikatet C 12 Merk som det fremkommer i A og gjennom positiv bedømmelse av B ifølge Serti...

Страница 3: ...may cause overheating electric shocks or fire Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box l...

Страница 4: ...ire to break out Do not install in sealed highly airtight spaces such as soundproof chambers and room which was sealed up the door This unit is equipped with a refrigerant leak detector for safety To be effective the unit must be electrically powered at all times after installation other than short service intervals This unit is equipped with electrically powered safety measures To be effective th...

Страница 5: ...ate 1 Insulation sheet 2 AAA dry cell batteries 2 Titanium Apatite Deodorizing Filter 2 Wireless remote controller 1 Operation manual 1 Drain hose 1 Remote controller holder 1 Installation manual 1 Outdoor units Cool Heat RXM25 50 Outdoor temperature 10 46 C DB 15 24 C DB 15 18 C WB Indoor temperature 14 28 C WB 10 30 C DB 2MXM40 50 3MXM40 68 4MXM68 80 5MXM90 Outdoor temperature 10 46 C DB 15 24 C...

Страница 6: ...otentially happen during normal operation service or maintenance Pipework shall only be installed in a room smaller than the minimum size as defined in the table below if the pipes have no connecting joints and do not have bends with a centerline bend radius less than the minimum bend radius mentioned in chapter 6 2 Selection of copper and heat insulation materials Floor area where the indoor unit...

Страница 7: ...he dipswitch settings Set according to the type of unit purchased by the customer The default settings are on the heat pump side For cooling only Set the dipswitches on the cooling only side For heat pump Check that the dipswitches are on the heat pump side If they are set on the cooling only side move them to the heat pump side H P C O Dipswitches H P C O Dipswitches 3PEN477070 1F book Page 5 Thu...

Страница 8: ...all be used Exposed Half concealed Floor Installation Wall Installation Mounting plate A Molding 64 644 134 700 600 574 26 140 230 250 35 35 210 160 150 Unit mm Mounting plate A The mounting plate should be installed on a wall which can support the weight of the indoor unit A Mounting plate fixing screw field supply M4 x 25L Titanium Apatite Deodorizing Filter 2 B Front grille Air filter Front pan...

Страница 9: ...al position 3 How to set the different addresses When two indoor units are installed in one room the two wireless remote controllers can be set for different addresses 1 Remove the front grille 2 Lift the sensor securing plate and remove the front metal plate cover 3 Remove connectors 5P 6P and 7P 4 Remove the electric box 1 screw 5 Remove the thermistor 6 Remove the side metal plate cover 7 tabs ...

Страница 10: ... the installation manual for the multi outdoor unit 2 Boring a wall hole and installing wall embedded pipe For walls containing metal frame or metal board be sure to use a wall embedded pipe and wall cover in the feed through hole to prevent possible heat electrical shock or fire Be sure to caulk the gaps around the pipes with caulking material to prevent water leakage 1 Bore a feed through hole o...

Страница 11: ... the front panel remove the 4 screws and dismount the front grille while pulling it forward Follow the procedure below when removing the slit portions For Moldings Remove the pillars Remove the slit portions on the bottom frame using nippers For Side Piping Remove the pillars 1 Remove the 7 screws 2 Remove the upper casing 2 tabs 3 Remove the left and right casings 2 tabs on each side 4 Remove the...

Страница 12: ... nut on the pipe 4 Flare the pipe 5 Check that the flaring is properly made WARNING 1 Do not use mineral oil on flared part 2 Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with the unit 4 Do never install a drier to this R32 unit in order to guarant...

Страница 13: ...052W mK 0 035 to 0 045kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Flare nut tightening torque Gas side Liquid side 25 35 class ...

Страница 14: ... butt joint with the included insulation sheet making sure there are no gaps CAUTION 1 Insulate the joint of the pipes securely Incomplete insulation may lead to water leakage 2 Push the pipe inside so it does not place undue force on the front grille 9 Connecting the drain hose Insert the supplied drain hose into the socket of the drain pan Fully insert the drain hose until it adheres to a seal o...

Страница 15: ...ctrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the power for the drain pump etc from the terminal block Doing so may cause electric shock or fire 3 Do not connect the power wire to the indoor unit Doing so may cause electric shock or fire 4 Use an all pole disconnection type breaker with at least 3 mm between the contact point gaps that provi...

Страница 16: ...ll hole Drill a wall hole of the size shown in the illustration on the right 2 Installation of supplemental plate for attaching main unit The rear of the unit can be fixed with screws at the points shown in the illustration as below Be sure to install the supplemental plate in accordance with the depth of the inner wall CAUTION 1 The supplemental plate for installing the main unit must be used or ...

Страница 17: ...he indoor unit 2 Install the indoor unit flush against wall NOTE For refrigerant piping Boring a wall hole and installing wall embedded pipe drain piping installing indoor unit flaring the pipe end connecting the refrigerant pipe checking for gas leakage attaching the connection pipe connecting the drain hose wiring when connecting to an HA system see Exposed Installation Left bottom piping Right ...

Страница 18: ...CE MONITOR GREEN HIGH VOLTAGE HIGH VOLTAGE IES INTELLIGENT EYE SENSOR IPM INTELLIGENT POWER MODULE K R KCR KFR KHuR K M MAGNETIC RELAY L LIVE L COIL L R REACTOR M STEPPER MOTOR M C COMPRESSOR MOTOR M F FAN MOTOR M P DRAIN PUMP MOTOR M S SWING MOTOR MR MRCW MRM MRN MAGNETIC RELAY N NEUTRAL n N NUMBER OF PASSES THROUGH FERRITE CORE PAM PULSE AMPLITUDE MODULATION PCB PRINTED CIRCUIT BOARD PM POWER MO...

Страница 19: ...sary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 1 4 After trial operation when the fan of indoor unit is spinning and the operation light is flashing there is a risk of refrigerant leakage so please ventilate the room and contact your dealer 2 Test items Tes...

Страница 20: ... 1903 3P477070 1F Two dimensional bar code is a code for manufacturing 3PEN477070 1F book Page 1 Thursday March 28 2019 9 06 AM ...

Отзывы: