6
■
English
Indoor Unit Installation Drawings
The indoor unit may be mounted in any of the three styles shown here.
Location for securing the installation panel.
WARNING
• Only use accessories, optional equipment and spare parts made or approved by DAIKIN.
• Installation shall be done by an installer, the choice of materials and installation shall comply with the applicable legislation.
In Europe, the EN378 is the applicable standard that shall be used.
Exposed
Half concealed
Floor Installation
Wall Installation
Mounting
plate
A
Molding
64
644
134
(700)
(600)
574
2
6
140
230
250
35
35
210
160
150
(Unit: mm)
Mounting plate
A
The
mounting plate should
be installed on a wall which can
support the weight of the indoor
unit.
A
Mounting plate fixing screw
(field supply: M4 x 25L)
Titanium Apatite Deodorizing Filter (2)
B
Front grille
Air filter
Front panel
50mm or more
from walls
70mm or more
50mm or more
from walls
Caulk pipe
hole gap
with putty.
Wireless remote
controller
Screws
(Field supply: M3 × 20L)
Remote controller
holder
E
F