• Outdoor Units • R-410A • RXS-G2V1B
• Split Sky Air • Outdoor Units
20
4
Capacity tables
4 - 1 Cooling/Heating capacity tables
3
24
4
FBQ5 RXS50G2V1B
Cooling 50Hz
220-240V
Heating 50Hz
220-240V
3TW31282-3A
Indoor
Outdoor temperature (°CDB)
EWB
EDB
20
25
30
32
35
40
°C
°C
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14.0
20
5.12
3.88
1.27
4.89
3.76
1.39
4.66
3.65
1.51
4.56
3.60
1.56
4.42
3.54
1.963
4.19
3.43
1.75
16.0
22
5.35
3.81
1.27
5.12
3.70
1.40
4.89
3.60
1.52
4.79
3.55
1.57
4.65
3.49
1.64
4.42
3.39
1.76
18.0
25
5.58
4.00
1.28
5.35
3.90
1.40
5.12
3.80
1.52
5.02
3.76
1.57
4.88
3.71
1.65
4.65
3.61
1.77
19.0
27
5.70
4.23
1.28
5.47
4.13
1.41
5.23
4.04
1.53
5.14
4.00
1.58
5.00
3.95
1.65
4.77
3.85
1.77
22.0
30
6.04
4.08
1.30
5.81
4.00
1.42
5.58
3.92
1.54
5.49
3.88
1.59
5.35
3.83
1.66
5.11
3.75
1.78
24.0
32
6.27
3.98
1.30
6.04
3.90
1.42
5.81
3.83
1.55
5.72
3.80
1.60
5.58
3.75
1.67
5.34
3.68
1.79
Indoor
Outdoor temperature (°CWB)
EDB
-10
-5
0
6
10
°C
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
15.0
3.70
1.36
4.32
1.43
4.94
1.50
5.69
1.58
6.19
1.63
20.0
3.51
1.40
4.13
1.47
4.75
1.53
5.50
1.61
6.00
1.67
22.0
3.44
1.41
4.06
1.48
4.68
1.55
5.42
1.63
5.92
1.68
24.0
3.36
1.43
3.98
1.50
4.60
1.56
5.35
1.64
5.84
1.70
25.0
3.32
1.44
3.94
1.50
4.56
1.57
5.31
1.65
5.81
1.70
27.0
3.25
1.45
3.87
1.52
4.49
1.58
5.23
1.66
5.73
1.72
S
YMBOLS
N
OTES
AFR : Air flow rate
(m3/min.)
1
Capacities are based on the following conditions,
(1) Corresponding refrigerant piping length: 5m
(2) Level difference
: 0m
2
shows nominal (rated) capacities and power input.
BF
: Bypass factor
EWB : Entering wet bulb temp.
(°C)
EDB
: Entering dry bulb temp.
(°C)
TC
: Total capacity
(kW)
SHC : Sensible heat capacity
(kW)
PI
: Power input
(kW)
AFR
16
BF
0.16
AFR
16