Test Operation and Confirmation
1. When the System is Not Working
Is the air conditioner working properly?
Are the connectors of the wiring properly connected?
Are the remote controller and field wiring properly connected?
Are all switch settings correct?
If there is nothing apparently wrong, conduct a diagnostic check using the following procedure.
Diagnostic check
2. Switch Settings and Connection Terminals
1
2
1
2
1
2
1
2
1
2
3
S
8
1
2
S
4
S
1
S
2
S
3
S
5
1
2
SW1
OFF ON
S6
CPU normal operation monitor
(Flashes when the operation is normal.)
SW1-1
SW1-2
S1
S2
S3
S4
S5
S6 connector
S8
Selecting the operation
mode
Selecting On/Off when
power is restored after
a power failure
SW1-1: OFF
(Operation mode 1)
SW1-1: ON
(Operation mode 2)
(1) - (2)
(1) - (2)
(1) - (3)
(+) - (–)
OFF
Operation mode 1 (Used with the exception of fan coil remote controller settings)
ON
Operation mode 2 (Used with fan coil remote controller settings)
OFF
Always Off
ON
Off if operation was in Off mode before power failure; On if operation was in
On mode before power failure
Instantaneous contact
Normal contact
S1 (1) - S2 (1)
OPEN
CLOSE
S1 (1) - S1 (2)
Pulse input
OPEN, Not activated
On/Off switching
CLOSE, Activated
S2 (2), S3
Not used
S1, S2 OPEN
Not activated
S1 (1) - S1 (2) CLOSE
On, airflow: L tap
S1 (1) - S2 (1) CLOSE
On, airflow: M tap
S1 (1) - S2 (2) CLOSE
On, airflow: H tap
S3 (With the remote
OPEN, Cooling
controller only)
CLOSE, Heating
Voltage on (DC12 V), normal operation light output
Normal operation light output (power for light required)
Malfunction light output (power for light required)
Connect with connector S21 on the PCB of the indoor unit
Relay DC 12 V power supply terminal (Field supplied parts)
START
Is the “CPU Normal” light
for the remote controller’s
PCB flashing?
No
Is 12 V DC being supplied
to No. 4 and No. 5 on S6 of the
remote controller’s PCB?
No
Yes
c
Is 12 V DC being supplied
to No. 4 and No. 5 on S21
of the indoor unit?
No
Yes
d
e
Is the malfunction light
of the remote
controller’s PCB on?
No
Yes
d
OR
e
f
Yes
c
Defect in adaptor PCB.
d
Defect in wiring.
e
Defect in indoor unit’s PCB.
f
Transmission error (between remote controller and indoor unit)
Содержание Quaternity FTXG09HVJU
Страница 1: ...EDUS04 906_a H Series Heat Pump...
Страница 44: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 43 Ground terminal...
Страница 45: ...Operation Manual EDUS04 906 44 Room Air Conditioners H Series DRY button...
Страница 46: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 45...
Страница 47: ...Operation Manual EDUS04 906 46 Room Air Conditioners H Series...
Страница 48: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 47...
Страница 50: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 49...
Страница 51: ...Operation Manual EDUS04 906 50 Room Air Conditioners H Series...
Страница 52: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 51...
Страница 55: ...Operation Manual EDUS04 906 54 Room Air Conditioners H Series...
Страница 56: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 55 1 8 F 1 C 3 6 F 2 C...
Страница 57: ...Operation Manual EDUS04 906 56 Room Air Conditioners H Series...
Страница 58: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 57 COOLING or DRY COOLING mode or...
Страница 59: ...Operation Manual EDUS04 906 58 Room Air Conditioners H Series...
Страница 60: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 59...
Страница 61: ...Operation Manual EDUS04 906 60 Room Air Conditioners H Series...
Страница 62: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 61...
Страница 63: ...Operation Manual EDUS04 906 62 Room Air Conditioners H Series...
Страница 64: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 63...
Страница 65: ...Operation Manual EDUS04 906 64 Room Air Conditioners H Series...
Страница 66: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 65...
Страница 67: ...Operation Manual EDUS04 906 66 Room Air Conditioners H Series...
Страница 68: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 67...
Страница 69: ...Operation Manual EDUS04 906 68 Room Air Conditioners H Series...
Страница 70: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 69 3P226009 1...
Страница 79: ...Optional Accessories EDUS04 906 78 Room Air Conditioners H Series...