Accessories
Choosing an Installation Site
• Before choosing the installation site, obtain user approval.
1.
Indoor unit.
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the
remote control range,
8) the unit is at least 3.5 ft (1m) away from any television or radio set (unit may cause interference with the picture or sound),
9) install at the recommended height (6 ft (1.8m)).
2.
Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly received
by the indoor unit (within 23 ft (7m)).
WARNING
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormally high pressure which could lead to equipment damage and personal injury.
• Be sure to install a ground fault circuit interrupter breaker.
Failure to install a ground fault circuit interrupter breaker may result in electrically shocks, or fire personal injury.
CAUTION
• Do not install the air conditioner where gas leakage would be exposed to open flames.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause water damage.
• Tighten the flare nut according to the specified torque. A torque wrench should be used.
If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage.
• Do not touch the heat exchanger fins.
Improper handling may result in injury.
• Be very careful about product transportation.
Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous.
Mounting plate
1
Wireless remote controller
1
Installation manual
1
Deodorizing filter for streamer
1
Remote controller holder
1
Mounting plate fixing screws
3/16” × 1”L (M4 × 25mm)
9
Titanium apatite photocatalytic
air-purifying filter
1
Dry batteries AAA. LR03
(alkaline)
2
Fixing screws for remote
controller holder
1/8” × 13/16”L (M3 × 20mm)
2
Indoor unit fixing screws
3/16” × 1/2”L (M4 × 12mm)
3
Operation manual
1
A
E
J
B
F
K
C
G
L
D
H
Содержание Quaternity FTXG09HVJU
Страница 1: ...EDUS04 906_a H Series Heat Pump...
Страница 44: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 43 Ground terminal...
Страница 45: ...Operation Manual EDUS04 906 44 Room Air Conditioners H Series DRY button...
Страница 46: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 45...
Страница 47: ...Operation Manual EDUS04 906 46 Room Air Conditioners H Series...
Страница 48: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 47...
Страница 50: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 49...
Страница 51: ...Operation Manual EDUS04 906 50 Room Air Conditioners H Series...
Страница 52: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 51...
Страница 55: ...Operation Manual EDUS04 906 54 Room Air Conditioners H Series...
Страница 56: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 55 1 8 F 1 C 3 6 F 2 C...
Страница 57: ...Operation Manual EDUS04 906 56 Room Air Conditioners H Series...
Страница 58: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 57 COOLING or DRY COOLING mode or...
Страница 59: ...Operation Manual EDUS04 906 58 Room Air Conditioners H Series...
Страница 60: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 59...
Страница 61: ...Operation Manual EDUS04 906 60 Room Air Conditioners H Series...
Страница 62: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 61...
Страница 63: ...Operation Manual EDUS04 906 62 Room Air Conditioners H Series...
Страница 64: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 63...
Страница 65: ...Operation Manual EDUS04 906 64 Room Air Conditioners H Series...
Страница 66: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 65...
Страница 67: ...Operation Manual EDUS04 906 66 Room Air Conditioners H Series...
Страница 68: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 67...
Страница 69: ...Operation Manual EDUS04 906 68 Room Air Conditioners H Series...
Страница 70: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 69 3P226009 1...
Страница 79: ...Optional Accessories EDUS04 906 78 Room Air Conditioners H Series...