• Outdoor Units • R410A • MXS-FV1B_F2V1B
1
4
• Split Sky Air • Outdoor Units
21
4
Capacity tables
4 - 1
Combination table
Heating [50Hz 230V]
Outdoor unit Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW)
Total capacity (kW)
Total input (W)
Total current (A)
Power factor %
ARoom
BRoom
CRoom
DRoom
Rating
(Min.
∼
max.)
Rating
(Min.
∼
max.)
Rating
(Min.
∼
max.)
Rating
3D056412
NOTES
1
Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).
Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).
2
The total ability of connected a indoor unit is up to 11.0 kW
3
It is impossible to connect the indoor unit for one room only.
4
The above is the value for connecting with the following indoor units.
2.0, 2.5, 3.5, 5.0 kW class: wall mounted D series
6.0 kW class: wall mounted F series
5
Capacities are based on the following conditions:
Corresponding refrigerant piping length : 5m
Level difference
: 0m
6
The bold line
Q
is indicated the rated combination of indoor unit.