Main unit

Do not use combustible substances, i.e., hair spray, insecticides, etc., 

• 

near the unit. 

Do not wipe the unit with benzene or thinner. 

These substances may lead to cracking, electric shock or ignition. 

Use a neutral detergent to clean the unit. 

• 

Use of chlorine or acidic detergents to clean the unit may generate harmful gas and harm health.

These servicing instructions are for use by quali

fi

 ed personnel only. 

• 

To reduce the risk of electric shock, do not perform any servicing 

other than that contained in the operating instructions unless you are 

a professional and quali

fi

 ed to do so.

Keep cigarettes, incense and other naked 

fl

 ames away from the unit. 

• 

Naked 

fl

 ames may lead to 

fi

 re.

Do not disassemble, remodel or service the unit by yourself. 

• 

Improper handling may lead to 

fi

 re, electric shock or injury. 

Consult your dealer.

Do not operate the unit with wet hands. 

• 

Contact with water may lead to electric shock.

Do not use the unit anywhere which is very humid such as bathrooms 

• 

or which experiences sudden temperature changes such as cold 

storage boxes. 

Improper environments may lead to electric shock or damage.

CAUTION

Power supply

cord and plug

Hold the power plug – not the power supply cord – and pull to 

• 

disconnect the unit. 

Pulling on the power supply cord may lead to 

fi

 re or electric shock because of short circuits.

Before long periods of disuse, disconnect the power plug from the 

• 

electrical socket. 

Degraded insulation may lead to electric shock, current leaks or 

fi

 re.

Main unit

Do not use the unit anywhere it is exposed to direct sunlight, rain or 

• 

wind. 

Overheating or contact with water may lead to 

fi

 re or electric shock. 

Do not use the unit anywhere which is hot such as near heaters. 

• 

High temperature may discolour or deform the unit. 

Do not block the air inlets or air outlet with laundry, cloth, curtains, 

• 

etc. 

Adhered lint may obstruct the air passage, possibly leading to overheating and 

fi

 re. 

Do not use the unit on an uneven 

fl

 oor.

• 

If the unit topples over, water may spill from it, possibly wetting furniture or leading to 

fi

 re or 

electric shock. 
If the unit topples over, put it upright immediately.

Do not use the unit anywhere chemicals are handled. 

• 

Volatile chemicals or solvents (found in hospitals, factories, test labs, beauty salons, photo 
developing labs, etc.) may degrade mechanical parts, possibly causing water leaks which may 
wet furniture, etc.

Do not use powders such as cosmetics near the unit. 

• 

Contact with powders may lead to electric shock or damage. 

Do not use the unit in cramped spaces such as closets. 

• 

Poor ventilation may lead to overheating and 

fi

 re.

01_EN_3P276413-3C.indd   4

01_EN_3P276413-3C.indd   4

9/27/2011   1:26:27 PM

9/27/2011   1:26:27 PM

Содержание MC70LPVM

Страница 1: ...Air Purifier OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70LPVM 00_CV_3P276413 3C indd 1 00_CV_3P276413 3C indd 1 9 17 2011 6 47 20 PM 9 17 2011 6 47 20 PM...

Страница 2: ...cle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes absorbed odour The decomposition cycle that maintains deodorising capability Adsorption The de...

Страница 3: ...onal issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operation Features 1 Safety Precautions 3 Name and Op...

Страница 4: ...complete connections may lead to electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by humidity o...

Страница 5: ...Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from the electrical socket Degraded insulation may...

Страница 6: ...ets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconnect the power plug and consult your dealer Do n...

Страница 7: ...container Front panel Ventilation fan Ionised wire rear Ionising frame Opposing pole plates Safety guard Unit display Page 7 Page 16 Page 16 Page 15 Streamer unit UNIT2 Page 20 gray Deodorising catal...

Страница 8: ...ng the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the setting Page 22 The sensitivity of the air quality...

Страница 9: ...evel remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types of odours such as pet odours other than ammonia...

Страница 10: ...attach the pleated filter before starting operation Remove the front panel 1 Push the 2 clips right and left and pull the front panel upward and remove it Push Clip 1 each on right and left Front pan...

Страница 11: ...t the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deodorising catalyst unit until you hear clicking s...

Страница 12: ...e cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside the unit and cable may cause a distorted TV pic...

Страница 13: ...octor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combustion may occur The replacement target is about...

Страница 14: ...ildproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds or more reconnect the power plug To operate the...

Страница 15: ...ng for the airflow rate returns to Auto fan Before cleaning make sure to stop operation and disconnect the power plug Auto fan operation The airflow rate is automatically selected from Quiet Low Stand...

Страница 16: ...e case of heavy dirt wash the prefilter with a soft brush or neutral detergent and dry it well in the shade Dry the prefilter completely before using it because the UNIT1 lamp may light up if any wate...

Страница 17: ...o not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odour sensor is clogged with dust use a vacuum clea...

Страница 18: ...m of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising catalyst unit until you hear clicking sound Attach UN...

Страница 19: ...left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green Knob white Wear rubber gloves Attach Attach the...

Страница 20: ...pole plates Procedure UNIT1 Ionising frame Ionised wire Opposing pole plates Remove the parts Page 9 Page 17 18 Page 18 Use a vacuum cleaner to remove the dust Soak in lukewarm water or water About 1...

Страница 21: ...s from the ionising frame or UNIT2 This may lead to damage Clean UNIT1 and UNIT2 somewhere which can be wet such as in a shower room or kitchen sink For stubborn dirt soak UNIT1 and UNIT2 in lukewarm...

Страница 22: ...ds The filter lamp goes off with a short beep sound Filter reset button Even if the pleated filter is replaced the filter lamp does not go off unless you press the filter reset button for 5 seconds NO...

Страница 23: ...on again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reacts to dust To lower the sensitivity Select the...

Страница 24: ...with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it will be deformed and become unusable When you hav...

Страница 25: ...e amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of the odour sensor Operate the unit with an increas...

Страница 26: ...d filter is replaced Did you press the filter reset button for 5 seconds Even if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off P...

Страница 27: ...26 MEMO 01_EN_3P276413 3C indd 26 01_EN_3P276413 3C indd 26 9 27 2011 1 27 43 PM 9 27 2011 1 27 43 PM...

Страница 28: ...3P276413 3C M10B195B 1111 HT Two dimensional bar code is a code for manufacturing 00_CV_3P276413 3C indd 2 00_CV_3P276413 3C indd 2 9 17 2011 6 47 27 PM 9 17 2011 6 47 27 PM...