17

Removing and Attaching Each Part

Remove

Remove the front panel.

Push the 2 clips (right and left), and pull the front panel 

• 

upward and remove it.

Push

Clip
(1 each on right and left)

Front panel

Remove the pre

fi

 lter.

Hold the indent and pull the pre

fi

 lter. Then, unhook the 

• 

tabs (4 locations) of the pre

fi

 lter from the holes (2 each on 

the right and left) of UNIT1.

Pull the pre

fi

 lter to remove it.

Tabs

(2 each on 

right an left)

Pre

fi

 lter

Note

Use a vacuum cleaner to 
remove the dust before 
removing the pre

fi

 lter.

Remove UNIT1.

Holding UNIT1 by the handles, pull UNIT1 upward and 

• 

remove it.

Handles

UNIT1

1) 
Pull

2) 
Up

Remove the deodorising catalyst unit.

Holding the deodorising catalyst unit by the handles, pull 

• 

the deodorising catalyst unit upward and remove it.

Handles

Deodorising catalyst unit

1) 
Pull

2) 
Up

Attach

Attach the deodorising catalyst unit. 

Holding the deodorising catalyst unit by the handles, 

fi

 t the 

• 

projections into the grooves (4 locations) at the bottom of 
the main unit and, press the deodorising catalyst unit into 
the main unit. 

Handles

Deodorising 
catalyst unit

1) 
Fit here.

2)  Press the deodorising catalyst unit 

until you hear clicking sound.

Attach UNIT1.

Holding UNIT1 by the handles, 

fi

 t the projections into the 

• 

grooves (2 locations) at the bottom of the main unit, and 
press UNIT1 into the main unit.

Handles

UNIT1

1) 
Fit here.

2)  Press UNIT1 until you 

hear clicking sound.

Attach the pre

fi

 lter.

Fit the tabs (4 locations) of the pre

fi

 lter into the holes 

• 

(2 each on the right and left) of UNIT1.

Pre

fi

 lter

Other tabs 
(3 locations)

Upper left tab (1 location) 
(The upper left tab is shaped 
differently from the others.)

UNIT1

Attach the front panel. 

Fasten the top hooks (2 locations) of the front panel to the 

• 

top grooves (2 locations) of the main unit and then close 
the front panel.

Front panel

Top hooks (2 locations)

2)  Press the front panel until 

you hear clicking sound.

1)  Fasten the 

hooks.

Top grooves 
(2 locations)

[View from above]

If the front panel is improperly set, the safety switch 
may be activated. Operation may not start. 

Page 16.

 

01_EN_3P276413-3C.indd   17

01_EN_3P276413-3C.indd   17

9/27/2011   1:27:11 PM

9/27/2011   1:27:11 PM

Содержание MC70LPVM

Страница 1: ...Air Purifier OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70LPVM 00_CV_3P276413 3C indd 1 00_CV_3P276413 3C indd 1 9 17 2011 6 47 20 PM 9 17 2011 6 47 20 PM...

Страница 2: ...cle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes absorbed odour The decomposition cycle that maintains deodorising capability Adsorption The de...

Страница 3: ...onal issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operation Features 1 Safety Precautions 3 Name and Op...

Страница 4: ...complete connections may lead to electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by humidity o...

Страница 5: ...Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from the electrical socket Degraded insulation may...

Страница 6: ...ets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconnect the power plug and consult your dealer Do n...

Страница 7: ...container Front panel Ventilation fan Ionised wire rear Ionising frame Opposing pole plates Safety guard Unit display Page 7 Page 16 Page 16 Page 15 Streamer unit UNIT2 Page 20 gray Deodorising catal...

Страница 8: ...ng the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the setting Page 22 The sensitivity of the air quality...

Страница 9: ...evel remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types of odours such as pet odours other than ammonia...

Страница 10: ...attach the pleated filter before starting operation Remove the front panel 1 Push the 2 clips right and left and pull the front panel upward and remove it Push Clip 1 each on right and left Front pan...

Страница 11: ...t the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deodorising catalyst unit until you hear clicking s...

Страница 12: ...e cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside the unit and cable may cause a distorted TV pic...

Страница 13: ...octor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combustion may occur The replacement target is about...

Страница 14: ...ildproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds or more reconnect the power plug To operate the...

Страница 15: ...ng for the airflow rate returns to Auto fan Before cleaning make sure to stop operation and disconnect the power plug Auto fan operation The airflow rate is automatically selected from Quiet Low Stand...

Страница 16: ...e case of heavy dirt wash the prefilter with a soft brush or neutral detergent and dry it well in the shade Dry the prefilter completely before using it because the UNIT1 lamp may light up if any wate...

Страница 17: ...o not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odour sensor is clogged with dust use a vacuum clea...

Страница 18: ...m of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising catalyst unit until you hear clicking sound Attach UN...

Страница 19: ...left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green Knob white Wear rubber gloves Attach Attach the...

Страница 20: ...pole plates Procedure UNIT1 Ionising frame Ionised wire Opposing pole plates Remove the parts Page 9 Page 17 18 Page 18 Use a vacuum cleaner to remove the dust Soak in lukewarm water or water About 1...

Страница 21: ...s from the ionising frame or UNIT2 This may lead to damage Clean UNIT1 and UNIT2 somewhere which can be wet such as in a shower room or kitchen sink For stubborn dirt soak UNIT1 and UNIT2 in lukewarm...

Страница 22: ...ds The filter lamp goes off with a short beep sound Filter reset button Even if the pleated filter is replaced the filter lamp does not go off unless you press the filter reset button for 5 seconds NO...

Страница 23: ...on again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reacts to dust To lower the sensitivity Select the...

Страница 24: ...with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it will be deformed and become unusable When you hav...

Страница 25: ...e amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of the odour sensor Operate the unit with an increas...

Страница 26: ...d filter is replaced Did you press the filter reset button for 5 seconds Even if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off P...

Страница 27: ...26 MEMO 01_EN_3P276413 3C indd 26 01_EN_3P276413 3C indd 26 9 27 2011 1 27 43 PM 9 27 2011 1 27 43 PM...

Страница 28: ...3P276413 3C M10B195B 1111 HT Two dimensional bar code is a code for manufacturing 00_CV_3P276413 3C indd 2 00_CV_3P276413 3C indd 2 9 17 2011 6 47 27 PM 9 17 2011 6 47 27 PM...

Отзывы: