7

Name and Operation of Each Part

Remote controller

Page 13, 14.

 

Child proof lock button

It prevents small children from mishandling the unit.

Brightness adjustment button

The brightness of the unit display lamp can 
be adjusted.

Air

fl

 ow rate lamp (green)

An air

fl

 ow rate lamp indicates the air

fl

 ow 

rate during “ 

 (Auto fan)” and “air

fl

 ow 

manual” operation.

Air quality sensor lamp (dust sensor)

The three-colour indicators (green, yellow, red) indicate how unclean the air is.

When the air is clean, the green lamp lights up.

• 

In the following case, only the green lamp lights up for the initial 

 

„

7 seconds regardless of the uncleanness level. 

1)  Operation directly after attaching the front panel and UNIT1
2)  Operation directly after reconnecting the power plug

When the sensitivity of the air quality sensor is poor, change the setting.

 

„

Page 22.

 

The sensitivity of the air quality sensor may fall depending on the 

 

„

installation site or the size of particles. 

If this bothers you, change the installation site of the unit 

Page 11.

 

 or adjust 

the sensitivity of the air quality sensor. 

Page 22.

 

Dust

Low

High

Green

Yellow

Green

Red

Yellow

Green

Lights up

Detectable

Cigarette smoke, pollen, ticks, house dust, animal hair, diesel soot

Sometimes detectable

Steam, oil vapours

Unit display

Auto fan button

Turbo button

OFF TIMER 

button

Auto fan lamp (yellow)

Child proof lock lamp 

(orange)

ON / OFF button

Fan setting 

button

Anti-pollen 

button

Sleep mode 

button

01_EN_3P276413-2C.indd   7

01_EN_3P276413-2C.indd   7

9/27/2011   1:20:07 PM

9/27/2011   1:20:07 PM

Содержание MC70LBFVM

Страница 1: ...Air Purifier OPERATION MANUAL Floor Standing Wall hanging Type MODEL MC70LBFVM English 00_CV_3P276413 2C indd 1 00_CV_3P276413 2C indd 1 9 17 2011 9 39 03 AM 9 17 2011 9 39 03 AM...

Страница 2: ...cle size is quickly caught Deodorising and decomposing odour in the air The streamer discharge decomposes absorbed odour The decomposition cycle that maintains deodorising capability Adsorption The de...

Страница 3: ...rational issues You may smell an odour as a particle of ozone is generated The amount is negligible and does not harm your health CONTENTS Read before Operation Features 1 Safety Precautions 3 Name an...

Страница 4: ...he base Incomplete connections may lead to electric shock or fire because of overheating Periodically clean the dust and other matter from the power plug with a dry cloth Insulation failure caused by...

Страница 5: ...nit Pulling on the power supply cord may lead to fire or electric shock because of short circuits Before long periods of disuse disconnect the power plug from the electrical socket Degraded insulation...

Страница 6: ...ets do not urinate on the unit or bite the power supply cord This may lead to electric shock or fire In the event of abuse by pets stop operation disconnect the power plug and consult your dealer Do n...

Страница 7: ...lter container Front panel Ventilation fan Ionised wire rear Ionising frame Opposing pole plates Safety guard Unit display Page 7 Page 16 Page 16 Page 15 Streamer unit UNIT2 Page 20 gray Deodorising c...

Страница 8: ...ng the front panel and UNIT1 2 Operation directly after reconnecting the power plug When the sensitivity of the air quality sensor is poor change the setting Page 22 The sensitivity of the air quality...

Страница 9: ...ur level remains constant without intensifying or weakening the odour sensor may not detect even strong odours The odour sensor may not detect certain types of odours such as pet odours other than amm...

Страница 10: ...attach the pleated filter before starting operation Remove the front panel 1 Push the 2 clips right and left and pull the front panel upward and remove it Push Clip 1 each on right and left Front pan...

Страница 11: ...s fit the projections into the grooves 4 locations at the bottom of the main unit and press the deodorising catalyst unit into the main unit 2 Press the deodorising catalyst unit until you hear clicki...

Страница 12: ...e cleaning the air during heating or cooling operation Keep TVs radios and stereos 2m or more away from the unit The effects of the power circuit inside the unit and cable may cause a distorted TV pic...

Страница 13: ...a doctor immediately When discarding batteries cover the terminals of the batteries with tape If mixed with other metal or batteries heat explosion or combustion may occur The replacement target is a...

Страница 14: ...ildproof lock by pressing again for about 2 seconds You can also release the childproof lock when you disconnect the power plug once and after 3 seconds or more reconnect the power plug To operate the...

Страница 15: ...etting for the airflow rate returns to Auto fan Before cleaning make sure to stop operation and disconnect the power plug Auto fan operation The airflow rate is automatically selected from Quiet Low S...

Страница 16: ...e case of heavy dirt wash the prefilter with a soft brush or neutral detergent and dry it well in the shade Dry the prefilter completely before using it because the UNIT1 lamp may light up if any wate...

Страница 17: ...nt Do not wash with water If the unit is washed with water it will be deformed and become unusable If the main unit or the air inlet for the air quality odour sensor is clogged with dust use a vacuum...

Страница 18: ...m of the main unit and press the deodorising catalyst unit into the main unit Handles Deodorising catalyst unit 1 Fit here 2 Press the deodorising catalyst unit until you hear clicking sound Attach UN...

Страница 19: ...and left at the same time makes it easier to remove the opposing pole plate Be careful not to cut the internal ionised wires Opposing pole plates Knob green Knob white Wear rubber gloves Attach Attach...

Страница 20: ...t with a piece of cloth soft brush etc Wear rubber gloves Cloth Cotton swab For details 1 Ionising frame 2 Ionised wire Wear rubber gloves Wipe Brush Cloth Rub Wear rubber gloves Rinse in running wate...

Страница 21: ...are deformed deodorising capacity diminishes For details 3 Streamer unit Cloth Cotton swab Wear rubber gloves Wipe If detergent remains on UNIT1 or UNIT2 the UNIT1 and UNIT2 lamps do not go off after...

Страница 22: ...lter The replacement interval for the pleated filter varies according to how the unit is used and where it is located The filter lamp lights up after about 2 years if the unit is used every day in a h...

Страница 23: ...ration again from the beginning Airflow rate lamp Sensitivity To raise the sensitivity Select the Low airflow rate lamp Low High The sensor more readily reacts to dust To lower the sensitivity Select...

Страница 24: ...with water Does the unit need to be replaced Answer No the deodorising catalyst unit can not be washed with water If the unit is washed with water it will be deformed and become unusable When you hav...

Страница 25: ...large amount of odour generated when starting operation of the unit The odour level of the initial 1 minute is used as the standard for the sensitivity of the odour sensor Operate the unit with an inc...

Страница 26: ...d filter is replaced Did you press the filter reset button for 5 seconds Even if the pleated filter is replaced unless you press the filter reset button for 5 seconds the filter lamp does not go off P...

Страница 27: ...English 26 MEMO 01_EN_3P276413 2C indd 26 01_EN_3P276413 2C indd 26 9 27 2011 1 21 07 PM 9 27 2011 1 21 07 PM...

Страница 28: ...7 3A MC70LBFVM DAIKIN INDUSTRIES LTD Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC DAIKIN TCF 018 E3 10 2010 KEMA Quality B V 82726 KRQ EMC98 4545 EN60335 2 65 Shinri Sada Manager Q...

Страница 29: ...3P276413 2C M10B194B 1111 HT Two dimensional bar code is a code for manufacturing 00_CV_3P276413 2C indd 2 00_CV_3P276413 2C indd 2 9 17 2011 9 39 14 AM 9 17 2011 9 39 14 AM...

Отзывы: