Wear rubber gloves when wiping or rubbing the units.
Hands can be cut on the opposing pole plates, ionised wires and needles of streamer unit.
•
There are ionised wires on the rear of the opposing pole plates. Be careful not to snap these wires when removing and attaching the units.
If the unit is operated with broken ionised wires, the “UNIT1” lamp lights. While the lamp is lit, dust collecting capacity is low.
•
If any ionised wire is accidentally cut, it is necessary to replace the ionised wire with a new one. Consult your dealer.
•
(Do not replace the ionised wire by yourself.)
CAUTION
UNIT2
Notes
Streamer unit
Open the front panel and pull out
the streamer unit.
Do not remove the screws from the ionising frame or UNIT2.
•
This may lead to damage.
Clean UNIT1 and UNIT2 somewhere which can be wet such as in a shower room or
•
kitchen sink.
For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm water or water in which neutral
•
liquid detergent (i.e., kitchen cleaner, etc.) has been dissolved.
Use the amount of neutral liquid detergent indicated in the instructions for the detergent.
•
Do not use powdered, alkaline or acidic cleaner, and do not rub with hard brushes, etc.
•
Doing so may cause deformation, damage, or rust.
If the needles inside UNIT2 are deformed, deodorising capacity diminishes.
•
For details,
3) Streamer unit
Cloth
Cotton
swab
Wear rubber gloves.
Wipe
If detergent remains on UNIT1 or UNIT2, the “UNIT1” and “UNIT2” lamps do not go off
•
after cleaning, therefore rinse off the detergent well.
Do not leave any lint from cleaning cloths behind. Lint may lead to malfunctions.
•
Plastic parts may deform or discolour if exposed to direct sunlight.
•
If water remains on UNIT1 or UNIT2, even in small quantities, the “UNIT1” and “UNIT2”
•
lamps do not go off after cleaning, therefore dry them throughly in the shade.
Reattach the streamer unit as before.
ATTENTION
Operation can be performed safely without the streamer unit installed on the main unit, but this degrades the deodorising performance. Use
•
the main unit after the streamer unit is installed.
Clean the ionised wires
without dislodging them
from the V-groove.
3) Streamer unit
Wipe the needles lightly with
•
a soft piece of cloth such as a
cotton swab moistened with
water or neutral liquid
detergent if dust is adhered
to them.
Remove dirt from plastic
•
parts (
) and metal parts
in internal areas with a cotton
swab or a soft piece of cloth.
Do not remove the screws.
•
: Plastic parts
Wear rubber
gloves.
* If the needles are deformed,
deodorising capacity diminishes.
Cotton swab
Do not touch
the needles.
Wipe the needles
gently from the
base to the tip.