Trouble Shooting

Investigate the problem once again before requesting repairs.

Case

Check

Measure

Does not operate.

Is the power plug unplugged?

Securely insert it.

Is the front panel correctly set?

Securely set it.

Are the battery of the remote controller dead?

Replace with new battery. (Page 5)

The four airflow rate displays, LL (Quiet), 
L (Low), M (Standard) and H (High) are 
flashing at the same time.

Is there any foreign matter in the air outlet?

Remove the foreign matter.
For other cases, contact a Daikin dealer.

Air does not come out.

Cleaning effect is not obtained.

Is the unit installed at a location where the 
flow does not pass or are there obstructions 
close to the unit?

Remove the obstruction.

Is there too much dust in the pre-filter or 
Titanium apatite photocatalytic filter roll?

Clean or replace. (Pages 8, 9)

Is too much odors or smoke being generated?

For this case, contact a Daikin dealer.

Television screen is distorted.

Is a television or radio installed within 2m of 
this unit or is an indoor antenna being used 
close to this unit?

Separate the television, radio and indoor 
antenna from this unit by 2m or more.

Is the power cord or antenna of the television 
or radio close to this unit?

Separate the power cord and antenna of the 
television or radio as much as possible away 
from this unit.

During operation a crackling sound or a 
buzzing sound are heard.

Is the plasma ionizer securely set?

Securely set it.

Is dust adhering to the ionizing line of the 
plasma ionizer (resin part)?

Clean the plasma ionizer. (Page 9)

Has water entered into the spurt hole moist-
ening the negative ionization assembly?

If the negative ionization assembly is dry, the 
sound will go away.

Odor is coming from the air outlet.

Is a large amount of odor being generated 
temporarily? (Many people smoking or grilling 
meat.)

If operated, the odor will gradually go away.

If the pre-filter or plasma ionizer dirty?

Clean it. (Pages 8, 9, 10)

Clean monitor (Dust) is red and does not 
change.

Caused by dust clogging the inside of the dust 
sensor.

Remove the dust from the dust sensor air 
intake using nozzles for small spaces of an 
electric vacuum cleaner.
If the dust is removed and the unit is manually 
operated for about half a day, it will be 
restored to a normal state. (Page 11)

Clean monitor (Dust) is green and does 
not change.

Содержание MC704AVM

Страница 1: ...OPERATION MANUAL MODEL MC704AVM PHOTOCATALYTIC AIR PURIFIER English Deutsch Fran ais Nederlands Espa ol Italiano Portugues...

Страница 2: ...when sleeping Accessory Confirm that accessory parts are in order Tips for Appropriate Use When you want to remove house dust setting up the air purifier in low rooms is effective When you want to re...

Страница 3: ...periods of time the wall become dirty Do not use in the place of kitchen fans or cooker hood fans Adverse conditions of use can shorten service life of the pre lilter and ion filter as well as lead to...

Страница 4: ...ng infectiousness Offensive odors such as cigarettes garbage and exhaust gases NOx are also decomposed Toxic substances such as cigarettes carbon monoxide cannot be removed When first used there is a...

Страница 5: ...r Page 9 Flashes during cleaning period of plasma ionizer to notify that clean ing is necessary 13Titanium apatite photocatalytic filter roll Replace indicator Reset button When the replacement time f...

Страница 6: ...acement target is approximately 1 year but if the reception becomes difficult replace the batteries with new coin type battery CR2025 Coin type battery close to the recommended usage period may need t...

Страница 7: ...to the main unit 1 Hang the hooks two at the top of the front panel on the grooves of the top of the main unit 2 Hold the panel removal knobs two locations left and right and press into the main unit...

Страница 8: ...ightness of the photo operation lamp and clean monitors Press the BRIGHTNESS button Each time it is pressed the display will switch as shown below Only set to OFF when you are concerned about light co...

Страница 9: ...sma ionizer pull the upper portion toward you and lift it upward 3 Clean the pre filter After using a vacuum cleaner to remove any dust clean with water If it is very dirty use a soft brush or a neutr...

Страница 10: ...ist up the dark colors of the surface and then correctly insert into the hooks four of the plasma ionizer CAUTION If the front surface and rear surface of the filer are mis taken the performance will...

Страница 11: ...be careful not to cut your hands on the ionizing line Wearing rubber gloves is safer Be careful not to snag or cut the ionizing line If the ionizing line is cut request the Daikin dealer to replace i...

Страница 12: ...he currently set sensitivity 3 Change the settings using the Operation switch Stop button of the main unit Switches each time it is pressed The settings is shown in the airflow rate indicator 4 When y...

Страница 13: ...parate the television radio and indoor antenna from this unit by 2m or more Is the power cord or antenna of the television or radio close to this unit Separate the power cord and antenna of the televi...

Страница 14: ...0508 HT 3P068886 10R M03B106C...

Отзывы: