3-1
3. ELECTRONIC CONTROLLER
3.1 Function table
●
DECOS
3
c/d (Daikin Electronic Controller Operation System)
(Note) [PC]: Functions using personal computer
No.
Function division
Function
DECOS
Ⅲ
c/d
1
Control function
• Temperature control
✓
• Defrosting control
✓
• Humidity control
Optional
2
Initial setting
• With/without optional equipment (USDA, humidity) and horse power selection
✓
• Chartless function setting
✓
3
Setting
• Temperature
✓
• Defrosting interval
✓
• Humidity
✓
• [PC] --- Header information set of data logger
✓
4
Indication
• Operating mode (compressor running, defrosting,
✓
(Display panel)
in-range temperature, dehumidifying)
• Alarm
✓
• Return air temperature/set point temperature
✓
• Supply air temperature/set point temperature
✓
• Defrosting interval
✓
• Inside humidity/set point humidity
Optional
• Ambient temperature
✓
• High pressure
✓
• Low pressure
✓
• Power supply voltage
✓
• Total operating current
✓
• Compressor operating current
• Evaporator inlet temperature
✓
• Evaporator outlet temperature
✓
• Discharge gas temperature
✓
• Compressor suction gas temperature
✓
• Suction modulating valve opening
✓
• Electronic expansion valve opening
✓
• Return air temperature (during PTI only)
✓
• Supply air temperature (during PTI only)
✓
• Pulp temperature (USDA #1, #2, #3)
Optional
• Cargo temperature
Optional
5
Self-diagnosis and
• Sensor
Return air temperature sensor
✓
automatic back-up
Supply air temperature sensor
✓
Ambient temperature sensor
✓
High pressure sensor
✓
Low pressure sensor
✓
Voltage sensor
✓
Current sensor
✓
Evaporator inlet temperature sensor
✓
Evaporator outlet temperature sensor
✓
Discharge gas temperature sensor
✓
Compressor suction gas temperature sensor
✓
Humidity sensor
Optional
Pulp temperature sensor
Optional
Cargo temperature sensor
Optional
Data recorder sensor
Optional
• High pressure switch
✓
• Solenoid valve/hot gas modulating valve (leakage check)
✓
• Long defrosting
✓
• Over-voltage
✓
03̲LXE10E-A(1-14) 07.2.19 4:53 PM ページ 3-1
https://daikin-p.ru
Содержание LXE10E-A
Страница 142: ...5 7 An example of installation of CA devices inside q TransFRESH ASS Y A4 A5 CABLES W MOUNTING BOX q https daikin p ru...
Страница 177: ...7 8 https daikin p ru...
Страница 178: ...7 13 Schematic wiring diagram Connector type terminal board and rechargeable battery 7 9 https daikin p ru...
Страница 180: ...7 11 7 15 Schematic wiring diagram Connector type terminal board temperature recorder and dry battery https daikin p ru...
Страница 220: ...8 37 2 2 Inside 1 q Reheat coil https daikin p ru...
Страница 232: ...8 49 An example of installation of CA devices inside q TransFRESH ASS Y A4 A5 CABLES W MOUNTING BOX q https daikin p ru...
Страница 237: ...MEMO https daikin p ru...