EDUS041016
Installation Manual
Room Air Conditioners J-Series
45
9
Pump Down Operation
In order to protect the environment, be sure to pump down when relocating or disposing of the unit.
1) Remove the valve cap from liquid stop valve and gas stop valve.
2) Carry out forced cooling operation.
3) After 5 to 10 minutes, close the liquid stop valve with a hexagonal wrench.
4) After 2 to 3 minutes, close the gas stop valve and stop forced cooling operation.
How to forced cooling operation mode
Using the indoor unit ON/OFF button
Press the indoor unit ON/OFF button for at least 5 seconds. (Operation will start.)
• Forced cooling operation will stop automatically after around 15 minutes.
To force a trial operation to stop, press the indoor unit ON/OFF button.
Using the main unit’s remote controller
1) Press the “ON/OFF” button. (Operation will start.)
2) Press the “TEMP”
button and the “MODE” button at the same time.
3) Press the “MODE” button twice.
(
“
”
will be displayed and the unit will enter trial operation.)
4) Press the “MODE” button to return the operation mode to cooling.
• Trial operation will stop automatically after around 30 minutes. To force a trial operation to stop, press the “ON/OFF”
button.
CAUTION
• When pressing the switch, do not touch the terminal block. It has a high voltage, so doing so may cause electric shock.
• After closing the liquid stop valve, close the gas stop valve within 3 minutes, then stop the forced operation.
Gas
stop valve
Valve cap
Hexagonal
wrench
Close
Liquid
stop valve
Содержание J Series
Страница 1: ...EDUS041016 J Series Cooling Only Heat Pump SEER 13 Models ...
Страница 53: ...Operation Manual EDUS041016 52 Room Air Conditioners J Series 12 2 Operation Instructions ...
Страница 54: ...EDUS041016 Operation Manual Room Air Conditioners J Series 53 ...
Страница 55: ...Operation Manual EDUS041016 54 Room Air Conditioners J Series ...
Страница 56: ...EDUS041016 Operation Manual Room Air Conditioners J Series 55 ...
Страница 57: ...Operation Manual EDUS041016 56 Room Air Conditioners J Series ...
Страница 58: ...EDUS041016 Operation Manual Room Air Conditioners J Series 57 ...
Страница 59: ...Operation Manual EDUS041016 58 Room Air Conditioners J Series ...
Страница 60: ...EDUS041016 Operation Manual Room Air Conditioners J Series 59 ...
Страница 61: ...Operation Manual EDUS041016 60 Room Air Conditioners J Series ...
Страница 62: ...EDUS041016 Operation Manual Room Air Conditioners J Series 61 ...
Страница 63: ...Operation Manual EDUS041016 62 Room Air Conditioners J Series ...
Страница 64: ...EDUS041016 Operation Manual Room Air Conditioners J Series 63 ...
Страница 65: ...Operation Manual EDUS041016 64 Room Air Conditioners J Series ...
Страница 66: ...EDUS041016 Operation Manual Room Air Conditioners J Series 65 ...
Страница 67: ...Operation Manual EDUS041016 66 Room Air Conditioners J Series ...
Страница 68: ...EDUS041016 Operation Manual Room Air Conditioners J Series 67 ...
Страница 69: ...Operation Manual EDUS041016 68 Room Air Conditioners J Series ...
Страница 70: ...EDUS041016 Operation Manual Room Air Conditioners J Series 69 ...
Страница 71: ...Operation Manual EDUS041016 70 Room Air Conditioners J Series ...
Страница 72: ...EDUS041016 Operation Manual Room Air Conditioners J Series 71 ...
Страница 73: ...Operation Manual EDUS041016 72 Room Air Conditioners J Series ...
Страница 74: ...EDUS041016 Operation Manual Room Air Conditioners J Series 73 ...
Страница 75: ...Operation Manual EDUS041016 74 Room Air Conditioners J Series ...
Страница 76: ...EDUS041016 Operation Manual Room Air Conditioners J Series 75 ...
Страница 77: ...Operation Manual EDUS041016 76 Room Air Conditioners J Series 3P253185 2 ...