16
Start-up
Permitted cable cross sections for the cable bushings of the DHC Floor
Heating Controller:
Cable bushings
Cable cross section [mm
2
]
1
(J)
(see figure 2)
> 5.2
2
(K)
(see figure 2)
> 8.2
3
(L)
(see figure 2)
> 3.2
Permitted cable cross sections for connecting to the connecting terminals of
the DHC Floor Heating Controller:
rigid cable [mm
2
]
flexible cable with/
without ferrule [mm
2
]
0.75 – 1.50
0.75 – 1.50
6.2
Installation
To install the DHC Floor Heating Controller, proceed as follows:
1.
Insert a screwdriver in the opening slot
(C)
and push the
latch to open the cover
(D)
.
2.
Remove the cover by pulling it upwards (
see figure 5
).
Warning!
Disconnect from mains before removing the cover!
3.
Connect the neutral conductor to connecting terminal N
(G)
.
Press the terminal down using an appropriate screwdriver to open
the connecting terminal. Thread the corresponding cable. Release
the terminal to close it and to fix the cable
(see figure 6)
.