Binding Of Insulation Pipe
1. The slit direction should be upward.
2. It should be sealed with vinyl tape
without any gap.
3. Do not over tighten with vinyl tape.
Sectional view
'""�'
Hoatlrlou�pipoa,,,er .
lnsulatilrl
..
CornrrlJr,a,lonwtre
D
Let:=
G"'pipe
Ylnyll!lpe
Wrap vinyl tape with the slit of the heat insulation pipe cover facing up so that there are no gap . If there is a gap or if
it is tightened too much, it may cause condensation or water dripping.
-f
�
Heat insulationpipe cover
Slit
__ 7+-Z_J: r I I I I 1.£ I I I I I J
Slit
�
Vinyl1ape
_
This illustration shows the case of the left rear piping.
Sectional view
wire
Insulation tape
- Overwrap more than half of heat insulation tape.
- Wrap the heat insulation tape around all the
pipes from the right side to the left side of the
pipe that pass through the back side of indoor
unit.
Seal with putty or caulking material.
� WARNING---------------
Fill the gap from both the indoor side and the outdoor side to
Putty or caulking
material.
prevent dew condensation, misdetection of indoor temperature,
and invasion of small animals.
Sleeve
Wall cap
I (Indoor side} I� !(Outdoor side)I
8