10
FXSQ12MVJU FXSQ24MVJU
FXSQ36MVJU
FXSQ18MVJU FXSQ30MVJU
FXSQ48MVJU
2-1
2-1 ACCESSORIES
Check the following accessories are included with your unit.
• Screws for fixing panels are attached to decoration panel.
2-2 OPTIONAL ACCESSORIES
• Parts listed on the below table are required with this indoor
unit.
Table 1
∗
A minimum height of 16 3/4” from the ceiling is required to
install the canvas connection for the air inlet panel.
Table 2
FOR THE FOLLOWING ITEMS, TAKE SPECIAL
CARE DURING CONSTRUCTION AND CHECK
AFTER INSTALLATION IS FINISHED.
a. Items to be checked after completion of work
b. Items to be checked at time of delivery
Also review the “SAFETY CONSIDERATIONS”
c. Points for explanation about operations
2-3 NOTE TO THE INSTALLER
Be sure to instruct customers how to properly operate the
unit (especially cleaning filters, operating different functions,
and adjusting the temperature) by having them carry out
operations themselves while looking at the manual.
Name
Metal
clamp
Paper pattern
for installation
Drain hose
Insulation for
fitting
Quantity
1 pc.
1 pc.
1 pc.
1 each.
Shape
for gas pipe
for liquid pipe
Name
Sealing pad
Screws for duct flanges
Quantity
1 each
1 set
Shape
Large
mid
Name
Washer
for hanger
bracket
Clamp
Screws for
fixing the
paper pat-
tern for
installation
(Other)
• Operation manual
• Installation manual
• Sealing material
(Small 1 3/8×5 7/8)
(2 pcs.)
Quantity
8 pcs.
6 pcs.
6 pcs.
Shape
Model
Min. height
above ceiling
(in.)
Air inlet panel
Canvas con-
nection for
air inlet
panel
Color
White
FXSQ12MVJU
16 3/4
or more
∗
BYBS32DJW1
Installation
not required
13 3/4
or more
KSAJ25K36
FXSQ18MVJU
16 3/4
or more
∗
BYBS45DJW1
Installation
not required
13 3/4
or more
KSAJ25K56
FXSQ24MVJU
16 3/4
or more
∗
BYBS71DJW1
Installation
not required
13 3/4
or more
KSAJ25K80
FXSQ30 · 36 · 48MVJU
16 3/4
or more
∗
BYBS125DJW1
Installation
not required
13 3/4
or more
KSAJ25K160
Remote controller
Wired type
BRC1C71
Items to be checked
If not properly done, what is
likely to occur
Check
Are the indoor and outdoor
unit fixed firmly?
The units may drop, vibrate
or make noise.
Is the gas leak test finished?
It may result in insuffcient
cooling.
Is the unit fully insulated?
Condensate water may drip.
Does drainage flow
smoothly?
Condensate water may drip.
Does the power supply volt-
age correspond to that
shown on the name plate?
The unit may malfunction or
the components burn out.
Are wiring and piping cor-
rect?
The unit may malfunction or
the components burn out.
Is the unit safely grounded?
Dangerous at electric leak-
age.
Is wiring size according to
specifications?
The unit may malfunction or
the components burn out.
Is something blocking the air
outlet or inlet of either the
indoor or outdoor units?
It may result in insufficient
cooling.
Are refrigerant piping length
and additional refrigerant
charge noted down?
The refrigerant charge in the
system is not clear.
Items to be checked
Check
Did you explain about operations while showing the
operation manual to your customer?
Did you hand the operation manual over to your customer?
The items with WARNING and CAUTION marks in
the
operation
manual are the items pertaining to
possibillties for bodily injury and material damage in
addition to the general usage of the product. Accordingly, it
is necessary that you make a full explanation about the
described contents and also ask your customers to read the
operation manual.