2-2  OPTIONAL ACCESSORIES

• 

This indoor unit separately requires a decoration panel and a 
remote controller.

• 

Confirm if a decoration panel shown in the Table 1 is 
prepared and meets your model. 
(Refer to the installation manual attached to the decoration 
panel for how to install.)

Table 1

Unit model

Optional decoration panel

FXFQ25 · 32 · 40 · 50 · 63 ·  

80 · 100 · 125SVM

BYCQ125B-W1

Color : Fresh white

• 

There are 2 kinds of remote controller; wired type and 
wireless type. 
Install the remote controller to the place where the customer 
has given consent. 
Refer to the catalog for the applicable model. 
(Refer to the installation manual attached to the remote 
controller for how to install.)

CARRY OUT THE WORK GIVING CAUTION 
TO THE FOLLOWING ITEMS AND AFTER THE 
WORK IS COMPLETED CHECK THESE AGAIN.

1. 

Items to be checked after the installation work is 
completed

Items to be checked

In case of defective

Check column

Are the indoor and outdoor 
units rigidly fixed?

Drop · vibration · 
noise

Are the installation works of 
the outdoor and indoor units 
completed?

Does not operate · 
burnout

Have you carried out a 
leakage test with the test 
pressure specified in the 
outdoor unit installation 
manual?

Does not cool / Does 
not heat

Is the insulation of 
refrigerant piping and drain 
piping completely carried 
out? 

Water leakage

Does the drain flow out 
smoothly?

Water leakage

Is the power supply voltage 
identical to that stated in the 
manufacturer’s label on the 
air conditioner?

Does not operate · 
burnout

Are you sure that there is no 
wrong wiring or piping or no 
loose wiring?

Does not operate · 
burnout

Is earthing completed?

Danger in case of 
leakage

Are the sizes of electric 
wiring according to the 
specification?

Does not operate · 
burnout

Is any of air outlets or 
inlets of the indoor and 
outdoor units blocked with 
obstacles?
(It may lead to capacity drop 
due to fan speed drop or 
malfunction of equipment.)

Does not cool /  
Does not heat

Have you recorded the 
refrigerant piping length 
and the refrigerant charge 
added?

Refrigerant charge 
amount is not clear

Make sure to recheck the items of “SAFETY PRECAUTIONS”.

2. 

Items to be checked at delivery 

Items to be checked

Check column

Have you carried out field setting? (if necessary)

Are the control box lid, the air filter and the suction 
grille attached?
Does the cool air discharge during the cooling 
operation and the warm air discharge during the 
heating operation? Does the indoor unit makes 
unpleasant sound of air discharge?
Have you explained how to operate the air 
conditioner showing the operation manual to the 
customer? 
Have you explained the description of cooling, 
heating, program dry and automatic (cooling/
heating) given in the operation manual to the 
customer?
If you set the fan speed at thermostat OFF, did you 
explain the set fan speed to the cus tomer.
Have you handed the operation manual and the 
installation manual to the customer?

Points of the operation explanation

In addition to the general usage, since the items in the 

operation manual with the 

WARNING and  

CAUTION marks are likely to result in human bodily 

injuries and property damages, it is neces sary not only 

to explain these items to the customer but also to have 

the customer read them.

3.  SELECTION OF INSTALLATION LOCATION

Hold the hangers at 4 locations to move the indoor unit 

when unpacking or after unpacked, and do not apply force 

to the piping (refrigerant and drain) and resin parts. 

If the temperature and humidity in the ceiling is likely to 

exceed 30°C, RH80%, use the optional kit for coping with 

high temperature and humidity, or additionally stick the 

insulation to the indoor unit. 

Use the insulation such as glass wool or polyethylene 

that has thickness of 10 mm or more. However, keep the 

insulated outside dimension smaller than the ceiling 

opening so that the unit may go through the opening at 

installation.

The direction of air discharge for this product can be 

selected. Sealing material of air discharge outlet is 

available option for 4-way with sealed corners, and 3-way.

(1)  Select the installation location that meets the following 

conditions and get approval of the cus tomer. 

• 

Where the cool and warm air spreads evenly in the 
room.

• 

Where there is no obstacles in the air passage.

• 

Where drainage can be ensured.

• 

Where the ceiling lower surface is not remarkably 
inclined.

• 

Where there is sufficient strength to withstand the mass 
of the indoor unit. (If the strength is insufficient, the in

-

door unit may vibrate and get in contact with the ceiling 
and generate unpleasant chattering noise.)

• 

Where a space sufficient for installation and service can 

be ensured. 

(Refer to Fig. 1)

• 

Where the piping length between the indoor and the out-
door units is ensured within the allowable length. (Refer 
to the installation manual attached to the outdoor unit.)

• 

Where there is no risk of flammable gas leak.

3P335596-2D        English

Содержание FXFQ25SVM

Страница 1: ...ensing FXFQ25SVM FXFQ63SVM FXFQ32SVM FXFQ80SVM FXFQ40SVM FXFQ100SVM FXFQ50SVM FXFQ125SVM INSTALLATION MANUAL CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR...

Страница 2: ...h may result in the air conditioner falling down and causing injury In addition it may lead to vibration of indoor units and cause unpleasant chattering noise Carry out the specified installation work...

Страница 3: ...ance that the refrigerant to be used for installation work is R410A The air conditioner will not properly operate if a wrong refrigerant is used For installation of the outdoor unit refer to the insta...

Страница 4: ...ing operation and the warm air discharge during the heating operation Does the indoor unit makes unpleasant sound of air discharge Have you explained how to operate the air conditioner showing the ope...

Страница 5: ...perature heat generating equipment is in stalled Each sensor has been set so that the center of the sensing area is located in the center of the product 800 mm above the floor in case of the infrared...

Страница 6: ...to reinforce the ceiling framework to keep the level of the ceiling and prevent vibration of the ceiling For details consult with the builder and interior designer 3 Install the hanging bolts Use M8...

Страница 7: ...n piping side gets high it may cause malfunction of a float switch and results in water leakage Attach nuts on the upper and lower side of hanger If there is no upper nut and the lower nut is over tig...

Страница 8: ...rench use Table 3 as a rule of thumb When tightening a flare nut with a spanner harder and harder there is a point where the tightening torque sud denly increases From that position tighten the nut ad...

Страница 9: ...nitrogen flow through the piping is approximately 0 02 MPa a pressure that makes one feel like breeze and can be obtained through a pres sure reducing valve 2 Do not use flux when brazing refrigerant...

Страница 10: ...the tip of the metal clamp 2 inward as shown Refer to Fig 16 In case of sticking vinyl tape Tightened part approx 90 Stick vinyl tape without tearing the sealing material Large 10 Vinyl tape In case...

Страница 11: ...ng the drainage of water refer to Fig 20 and attach the sealing material 14 to perform the thermal insulation of the drain socket Sealing material 14 accessory Fig 20 When the electric wiring work is...

Страница 12: ...nit always wiring the indoor unit to the terminal indicated with the same symbol on the terminal block If the wiring and the piping are connected to the different indoor units and operated it will res...

Страница 13: ...ning cannot be car ried out If a terminal is over tightened it may be damaged Refer to the table shown below for tightening torque of terminals Tightening torque N m Terminal block for remote controll...

Страница 14: ...supply wiring high voltage R10 or more R10 or more Strand the wirings after sheath is peeled off After the wirings are clamped cut off the extra part After the wirings are clamped cut off the extra pa...

Страница 15: ...L Remote controller option Remote controller option Remote controller option L N L N L N P1P2 F1 F2 T1 T2 P1P2 P1P2 F1 F2 T1 T2 P1P2 P1P2 F1 F2 T1 T2 P1P2 No 2 system When carrying out group control o...

Страница 16: ...ore 9 MOUNTING DECORATION PANEL CAUTION In case of a wireless remote controller unless the decoration panel is mounted field setting and test opera tion cannot be carried out Refer to the installation...

Страница 17: ...cleaning indication is not necessary such as the case of periodical clean ing being carried out TEST OPERATION After cleaning the indoor unit inside carry out test operation according to installation...

Страница 18: ......

Страница 19: ......

Страница 20: ...1310 FS 3P335596 2D EM13A007...

Отзывы: