• Indoor Unit • 2-way blow ceiling mounted cassette • FXCQ-A

1

2

• VRV Systems • Indoor Unit

4

2

Specifications

Standard Accessories : Declaration of conformity;
Standard Accessories : Installation manual;
Standard Accessories : Operation manual;

 Notes

 (1) Cooling: indoor temp. 27ºCDB, 19ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 7.5m (horizontal)
 (2) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 7.5m (horizontal)
 (3) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
 (4) Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
 (5) Maximum allowable voltage range variation between phases is 2%.
 (6) MCA/MFA: MCA = 1.25 x FLA
 (7) MFA 

 4 x FLA

 (8) Next lower standard fuse rating minimum 16A
 (9) Select wire size based on the value of MCA
 (10) Instead of a fuse, use a circuit breaker

2-2 Electrical Specifications

FXCQ20A

FXCQ25A

FXCQ32A

FXCQ40A

FXCQ50A

FXCQ63A

FXCQ80A

FXCQ125A

Power supply

Name

VE

Phase

1~

Frequency

Hz

50

Voltage

V

220-240

Voltage range

Min.

%

-10

Max.

%

10

Current - 50Hz

Minimum circuit amps (MCA)

A

0.3

0.4

0.5

0.6

1.1

Maximum fuse amps (MFA)

A

16

Full load amps 
(FLA)

Total

A

0.2

0.3

0.4

0.5

0.9

Содержание FXCQ-A

Страница 1: ...Air Conditioning Technical Data 2 way blow ceiling mounted cassette EEDEN13 204 FXCQ A...

Страница 2: ......

Страница 3: ...ical Data 5 4 Safety device settings 6 Safety Device Settings 6 5 Options 7 Options 7 6 Capacity tables 8 Cooling Capacity Tables 8 Heating Capacity Tables 9 Capacity Correction Factor 10 7 Dimensiona...

Страница 4: ...s close entirely when not in operation Improved comfort thanks to automatic air flow adjustment to required load Individual flap control one flap can be easily closed via the wired remote controller B...

Страница 5: ...Q40HW1 BYBCQ63HW1 BYBCQ125HW1 Colour Fresh white 6 5Y 9 5 0 5 Dimensions Height mm 55 Width mm 1 070 1 285 1 740 Depth mm 700 Weight kg 10 11 13 Heat exchanger Rows Quantity 2 Fin pitch mm 1 2 Face ar...

Страница 6: ...r fan motor heat 4 Voltage range units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits 5 Maximum allowable voltage range va...

Страница 7: ...3 1 3 VRV Systems Indoor Unit 5 Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 3 Electrical data 3 1 Electrical Data...

Страница 8: ...Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 1 4 VRV Systems Indoor Unit 6 4 Safety device settings 4 1 Safety Device Settings...

Страница 9: ...3 1 5 VRV Systems Indoor Unit 7 Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 5 Options 5 1 Options...

Страница 10: ...HOOHV UpHOOHV GH O pTXLSHPHQW LQWpULHXU GLIIqUHQW GH FHOOHV LQGLTXpHV GDQV OH WDEOHDX HQ UDLVRQ GH OD PRGL FDWLRQ GH OD WHPSpUDWXUH GH O DLU ext rieure et du facteur de charge Falls Bedingungen aufgru...

Страница 11: ...HU RQVWUXNWLRQVDQIRUGHUXQJHQ QDFK GHU 6 VWHPDXVZDKO DEZHLFKHQ GDQQ ZHLFKW DXIJUXQG GHU bQGHUXQJHQ der Au enlufttemperatur und des Lastfaktors die tats chliche Betriebsf higkeit der Innenanlage von der...

Страница 12: ...08 1 086 1 061 1 041 FXCQ32 TC 0 681 0 690 0 741 0 766 0 787 0 817 0 842 SHF 1 147 1 192 1 135 1 108 1 086 1 061 1 041 FXCQ40 TC 0 671 0 687 0 748 0 772 0 792 0 821 0 854 SHF 1 167 1 191 1 128 1 101 1...

Страница 13: ...45 1 192 1 127 1 089 FXCQ32 TC 0 546 0 559 0 570 0 603 0 637 0 690 0 730 SHF 1 147 1 250 1 306 1 245 1 192 1 127 1 089 FXCQ40 TC 0 540 0 548 0 571 0 611 0 645 0 697 0 744 SHF 1 167 1 273 1 300 1 231 1...

Страница 14: ...Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 1 7 VRV Systems Indoor Unit 12 7 Dimensional drawings 7 1 Dimensional Drawings...

Страница 15: ...3 1 7 VRV Systems Indoor Unit 13 Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 7 Dimensional drawings 7 1 Dimensional Drawings...

Страница 16: ...Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 1 8 VRV Systems Indoor Unit 14 8 Centre of gravity 8 1 Centre of Gravity...

Страница 17: ...3 1 9 VRV Systems Indoor Unit 15 Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 9 Piping diagrams 9 1 Piping Diagrams...

Страница 18: ...Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 1 10 VRV Systems Indoor Unit 16 10 Wiring diagrams 10 1 Wiring Diagrams Single Phase...

Страница 19: ...3 1 11 VRV Systems Indoor Unit 17 Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 11 Sound data 11 1 Sound Pressure Spectrum...

Страница 20: ...Indoor Unit 2 way blow ceiling mounted cassette FXCQ A 1 11 VRV Systems Indoor Unit 18 11 Sound data 11 1 Sound Pressure Spectrum...

Страница 21: ...4 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this leaflet to the best of i...

Отзывы: