background image

En

gl

is

h

For  any  enquiries  on  spare  parts,  please  contact  your  authorized  dealer.  If  any  malfunction  of  the  air 
conditioner unit is noted, immediately switch off the power supply to the unit. Check the following fault 
conditions and causes for some simple troubleshooting tips.

14

TROUBLESHOOTING

Fault

Causes / Action

The air conditioner unit does not operate.

1.

Power failure, or the fuse need to be replaced.

The power plug is disconnected.

The air flow is too low.

2.

The air filter is dirty.

The doors or windows are open.

The air suction and discharge are clogged.

 The regulated temperature is not high enough. 

Discharge air flow has bad odor.

3.

Odors  may  be  caused  by  cigarettes,  smoke  particles, 
perfume etc. which might have adhered onto the coil.

Water flowing out from the air conditioner unit.

4.

Switch off unit and call local dealer / serviceman.

If the fault persists, please call your local dealer / serviceman.

SERVICE AND MAINTENANCE

!

 CAUTION

Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to deform as a 
result of chemical reaction. 

Service Parts

Maintenance Procedures

Period

Indoor Air Filter

Remove any dust adhered on the filter by using a vacuum cleaner or wash 
in lukewarm water (below 40°C) with neutral cleaning detergent.

Rinse well and dry the filter before placing it back onto the unit.

Do not use gasoline, volatile substances or chemical to clean the filter.

1.

2.

3.

At least once every 
2 weeks.

More frequently 
if necessary.

Indoor Unit

Clean any dirt or dust on the grille or panel by wiping it using soft cloth 
soaked in lukewarm water (below 40°C) with neutral detergent solution.

Do not use gasoline, volatile substances or chemical to clean the indoor 
unit.

1.

2.

At least once every 
2 weeks.

More frequently 
if necessary.

Содержание FWC02G

Страница 1: ...FAN COIL UNIT G SERIES IM CCGW 0821 5 DAIKIN Part Number R08019045598 Installation Manual Chilled Water Fan Coil Unit English MODELS FWC02G FWC03G FWC04G FWC06G FWC08G FWC10G FWC12G FWC14G FWC16G FWC...

Страница 2: ...6 0 CONDENSATE DRAIN R3 4 198 267 KD KC 187 43 104 161 219 461 132 KE 38 66 110 18 18 16 143 38 27 30 82 148 251 FWC02G WATER OUT 3 4 BSPT FEMALE THREADADAPTOR WATER IN 3 4 BSPT FEMALE THREADADAPTOR M...

Страница 3: ...74 155 18 16 248 119 143 328 363 25 660 175 109 KC KB 49 37 75 KA OUT IN 198 KE 187 43 104 18 143 27 161 219 251 18 148 132 110 38 26 267 KC 38 KB KA 16 59 WATER OUT 1 BSPT FEMALE THREADADAPTOR 142 WA...

Страница 4: ...78 1300 1354 1392 1298 14G 1142 1116 953 877 929 930 836 16 18G 1280 1254 1091 1015 1067 1068 974 20G 1420 1394 1231 1155 1207 1208 1114 FWC14 16 18 20G 12 203 59 12 KG 59 KF 24 363 KE KD KC KB KA 43...

Страница 5: ...or use in room where mineral oil oil vapour or oil steam exist this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction When the unit is used in kitchen keep f...

Страница 6: ...ong to withstand the weight 300mm or more 300mm or more Can be smaller than 300mm if ceiling is removable Floor 2300mm or more Ceiling Insulation material field supply 300mm or more Air outlet side Se...

Страница 7: ...se contaminated or damaged pipe and fitting for installation Some main fitting components are needed in the system to enhance the capacity and ease of service such as gate valve balancing valve 2 way...

Страница 8: ...08 230V 60Hz TH 220 240V 50Hz or 208 230V 60Hz 220 240V 50Hz or 208 230V 60Hz TH FSC FSC FL FM FH N FL FM FH N L N L N L N FL Fan Low FM Fan Medium FH Fan High N Neutral FSC Fan Speed Controller X1 X2...

Страница 9: ...er means for disconnection having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the relevant local and national legislation 7 2 8 1 2 2 8 2 2 8 0 1 2 3...

Страница 10: ...g wires to the power supply terminal block Connect the wires by matching to the indication on terminal block Refer to the wiring diagram attached on the unit Operating Limits Thermal carrier Water Ent...

Страница 11: ...ion guide for such unit The installation of fan coil unit may vary according to the type of outdoor unit Installation must be done by qualified personnel who is familiar with this type of product Ensu...

Страница 12: ...the Adaptor Holder INTERCHANGEABLE HEAT EXCHANGER PIPING DIRECTION GUIDE LINE The simulation below is based on FCU FWC G Unit From right piping direction to left piping direction To perform this simu...

Страница 13: ...ow the Hairpin move out and not touching the Side Panel MOVE UPWARDS STEP 7 While holding Heat Exchanger gently move out the Heat Exchanger Distributor from the Side Panel Please be aware of the relea...

Страница 14: ...pe is at the same side with the Adaptor Holder STEP 14 The changing of Heat Exchanger Pipe Direction is completed STEP 10 Then gently pull the Side Panel outwards to allow the Hairpin side of the Heat...

Страница 15: ...it 4 Switch off unit and call local dealer serviceman If the fault persists please call your local dealer serviceman SERVICE AND MAINTENANCE CAUTION Avoid direct contact of any coil treatment cleaners...

Страница 16: ...nato ku Tokyo 108 0075 Japan http www daikin com global Lot 10 Jalan Perusahaan 8 Kawasan Perusahaan Pekan Banting 42700 Banting Selangor D E Malaysia The manufacturer reserves the right to revise any...

Отзывы: