![Daikin FVXS09NVJU Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/daikin/fvxs09nvju/fvxs09nvju_service-manual_501431040.webp)
Main Functions
SiUS091601E
29
Functions and Control
1.8
NIGHT SET Mode
Outline
When the OFF TIMER is set, NIGHT SET Mode is automatically activated. NIGHT SET Mode
keeps the airflow rate setting.
Detail
NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in the
case of heating. This prevents excessive cooling in summer and excessive heating in winter to
ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Heating
1.9
ECONO Operation
Outline
ECONO operation reduces the maximum power consumption. This operation is particularly
convenient for energy-saving. It is also a major bonus when breaker capacity does not allow the
use of multiple electrical devices and air conditioners.
It can be easily activated by pushing
ECONO
button on the wireless remote controller.
Detail
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in cooling, heating, dry,
or automatic operation. This function can only be set when the unit is running. Press
ON/OFF
button on the remote controller to cancel the function.
This function and POWERFUL operation cannot be used at the same time. The latest command
has the priority.
(R21657)
TIMER operation
NIGHT SET Mode ON
Target temperature
+0.5˚C (+0.9˚F)
temperature shift
Operation stops
at the set hours
0.5˚C (0.9˚F)
1 hour
TIMER operation
NIGHT SET Mode ON
Target temperature
–2˚C (–3.6˚F)
temperature shift
1 hour
2˚C (3.6˚F)
(R21658)
ECONO operation
(R21051)
Normal operation
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
Содержание FVXS09NVJU
Страница 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5 ...
Страница 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57 ...
Страница 121: ...SiUS091601E Check Service Diagnosis 110 12 class 15 class Multimeter R23024 R20701 1 2 3 4 Multimeter ...
Страница 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition ...