Outdoor Unit
Printed Circuit Board Connector Wiring Diagram
18
2.3
RXL15QMVJU
Main PCB
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for DC fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) HL1, HN1, S
Connector for terminal board
7) E1, E2
Terminal for ground
8) U, V, W
Connector for compressor
9) FU1, FU2
Fuse (3.15 A, 250 V)
10)FU3
Fuse (30 A, 250 V)
11)J6
Jumper for facility setting
∗
Refer to page 121 for detail.
12)LED A
LED for service monitor (green)
13)V1, V2, V3
Varistor
U, V, W
FU3
FU1
FU2
V3
V2
V1
S20
S80
S40
S90
J6
S70
2P382390-14
E1, E2
HL1, HN1, S
LED A
Содержание FVXS09NVJU
Страница 12: ...SiUS091601E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 15: ...SiUS091601E Specifications 4 Part 2 Specifications 1 Specifications 5 ...
Страница 65: ...SiUS091601E Remote Controller 54 Part 5 Remote Controller 1 FTX Series 55 2 FVXS Series 57 ...
Страница 121: ...SiUS091601E Check Service Diagnosis 110 12 class 15 class Multimeter R23024 R20701 1 2 3 4 Multimeter ...
Страница 144: ...Revision History Month Year Version Revised contents 02 2016 SiUS091601E First edition ...