NOTE 

• Do not wash the air filter with water of 50°C or 

higher. 
It may cause decolorization and deformation. 

• Do not heat the filter with fire. 

It may cause burning.

4. Attach the air filter. 

Attach the air filter in the reverse order men-
tioned in the clause 2 (page 9).

5. Close the suction grille.

Simultaneously slide the two knobs, slowly lift 
the suction grille and securely fix it in the reverse 
order mentioned in the clause 1 (page 9).

6. Turn off the indication “

” or “Time to 

clean filter” displayed on the remote control-
ler after turning on the power. 

For details, refer to the operation manual 
attached to the remote controller.
The indication can be turned off whether in 
operation or at stop. 

NOTE 

When closing the suction grille, the strap is likely 
to be sandwiched.

Before closing the suction grille, confirm if the 
strap is not sticking out from the side of the 
suction grille. 

HOW TO CLEAN THE SUCTION GRILLE

1. Open the suction grille.

Simultaneously slide the two knobs, slowly down 
the suction grille. 

2. Remove the suction grille.

1

Remove the 4 straps attached to the indoor 
unit. (Refer to the figure shown below.)

Suction grille

Strap

Knob

Knob

2

Open the suction grille to 45° and lift it. Then, 
unhook it from the place to hook. 
(3 places) 

3. Take out the air filter.

Refer to the clause 2 for “

HOW TO CLEAN THE 

AIR FILTER

”. (page 9)

4. Clean the suction grille.

Wash the suction grille with neutral detergent 
using a soft brush and then dewater. 

When the suction grille is extremely contaminated

Spray the detergent for a ventilating fans and 
ranges directly to the suction grille, and keep it 
under that condition for about 10 minutes.
After that, carefully wash the suction grille with 
water.

NOTE 

• Do not wash the suction grille with warm 

water of 50°C or higher.
It may cause discoloration and deformation.

• When drying the suction grille, do not heat it 

with fire. It may cause burning.

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

5. Attach the air filter.

Refer to the clause 4 for “

HOW TO CLEAN THE 

AIR FILTER

”. (page 10)

Place to hook
(3 places)

Unhook 
the hook

Place where 
the straps are 
to be hooked 

Place where the 
straps are to be 
hooked (A total of 
4 places)

Detergent

01_EN_3P170549-16W.fm  Page 10  Thursday, February 20, 2014  5:28 PM

Содержание FUQ100CVEB

Страница 1: ...MANUAL MODELS 4 Way Blow Ceiling Suspended type SPLIT SYSTEM VRV SYSTEM FUQ71CVEB FXUQ71AVEB FUQ100CVEB FXUQ100AVEB FUQ125CVEB English Deutsch Fran ais Espa ol Italiano Nederlands Portugu s T rk e 00...

Страница 2: ...rdelo para futuras consultas Asimismo aseg rese de entregar este manual de instrucciones a un nuevo usuario Debido a que este manual de instrucciones est dedi cado a la unidad interior deber consultar...

Страница 3: ...tes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especial izadas para su r...

Страница 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Страница 5: ...amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched so...

Страница 6: ...he control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove the...

Страница 7: ...s a customized control system ask your local dealer for the operation that corre sponds to your system PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Страница 8: ...t bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ Read the operation manual attached to the out door unit Regarding places for installation Istheairco...

Страница 9: ...is used to prevent the dis charge of melt water The remote controller displays the fan speed that is set When the outdoor temperature is high it takes some time until the indoor temperature reaches th...

Страница 10: ...r the indoor temperature and humidity first use the COOLING OPERATION to lower the indoor temperature and then use the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the ind...

Страница 11: ...conditioner It may decrease the effect or stop the operation Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Not doing so wastes electricity When...

Страница 12: ...r filter It indicates after running for a certain time NOTE You may change the time of indication or Time to clean filter If the indoor unit is used in a space where the air is more contaminated ask y...

Страница 13: ...ched to the indoor unit Refer to the figure shown below Suction grille Strap Knob Knob 2 Open the suction grille to 45 and lift it Then unhook it from the place to hook 3 places 3 Take out the air fil...

Страница 14: ...order to activate the air condi tioner smoothly and to protect the air conditioner The display on the remote controller will be shown when the power circuit breaker is turned on HEATING OPERATION wit...

Страница 15: ...installation but every time the power cir cuit breaker is turned off on 9 NOT MALFUNCTION OF THE AIR CONDITIONER For comfortable use do not turn off the power circuit breaker during seasonal use of t...

Страница 16: ...unit Ask your local dealer for details on cleaning the indoor unit This cleaning requires a qualified service person Check the usage environment When the air conditioner is changed over to the HEATIN...

Страница 17: ...vers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles Remove the obstacle and make it well venti la...

Страница 18: ...his time please tell the symptom and model name written on the model name plate If one of the following malfunctions occurs take the measures shown below and contact your local dealer The air conditio...

Страница 19: ...3P170549 16W EM12A001A 1404 HT 00_CV_3P170549 16W_01 fm Page 2 Saturday February 15 2014 6 19 PM...

Отзывы: