background image

10

 | 

Wireless LAN adapter installation

Installer reference guide

42

FTXP-N

Daikin room air conditioner

4P518023-14L – 2022.06

10 Wireless LAN adapter installation

10.1 About the wireless LAN

For  detailed  specifications,  installation  instructions,  setting  methods,  FAQ,
declaration  of  conformity  and  the  latest  version  of  this  manual,  visit

app.daikineurope.com

.

INFORMATION: Declaration of conformity

Daikin  Industries  Czech  Republic  s.r.o.  declares  that  the  radio  equipment  type
inside  of  this  unit  is  in  compliance  with  Directive  2014/53/EU  and
S.I. 2017/1206: Radio Equipment Regulations 2017.

This  unit  is  considered  as  combined  equipment  according  to  the  definition  of
Directive 2014/53/EU and S.I. 2017/1206: Radio Equipment Regulations 2017.

INFORMATION

Install  the  wireless  LAN  adapter  after  finishing  the  indoor  unit  installation.  Refer  to

"10 Wireless LAN adapter installation"

 [

4

 42].

10.1.1 Basic parameters

What

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

1~11

Output power

0 dBm~18 dBm

Effective radiated power

17 dBm (11b) / 13 dBm (11g) / 12 dBm
(11n)

Power supply

DC 14 V / 100 mA

10.2 To install the adapter

DANGER: RISK OF ELECTROCUTION

Turn off the power supply before installing the adapter.

Do NOT handle the adapter with wet hands.

Do NOT let the adapter get wet.

Do NOT disassemble, modify or repair the adapter.

Grip the connector when disconnecting the connecting cord.

Turn off the power supply in case the adapter gets damaged.

Содержание FTXP50N2V1B

Страница 1: ...Installer reference guide Daikin room air conditioner FTXP50N2V1B FTXP60N2V1B FTXP71N2V1B...

Страница 2: ...on right side right back or right bottom 26 6 4 3 To connect the piping on left side left back or left bottom 27 6 4 4 To check for water leaks 28 7 Piping installation 29 7 1 Preparing refrigerant pi...

Страница 3: ...the unit 43 10 2 2 To place the adapter into the unit 44 10 2 3 To check the functionality of the adapter 45 10 3 To install the ONECTA app 45 11 Configuration 46 11 1 To set a different channel of t...

Страница 4: ...ld use by lay persons Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you MUST read before installing Fo...

Страница 5: ...ION Indicates a situation that could result in explosion WARNING Indicates a situation that could result in death or serious injury WARNING FLAMMABLE MATERIAL CAUTION Indicates a situation that could...

Страница 6: ...aikin room air conditioner 4P518023 14L 2022 06 Symbol Explanation Indicates a figure title or a reference to it Example 1 3 Figure title means Figure 3 in chapter 1 Indicates a table title or a refer...

Страница 7: ...ructions described in the Daikin documentation WARNING Tear apart and throw away plastic packaging bags so that nobody especially children can play with them Possible risk suffocation WARNING Provide...

Страница 8: ...where there is a risk of fire due to the leakage of flammable gases example thinner or gasoline carbon fibre ignitable dust In places where corrosive gas example sulphurous acid gas is produced Corro...

Страница 9: ...fects Provide space for expansion and contraction of long runs of piping Design and install piping in refrigerating systems such as to minimise the likelihood of hydraulic shock damaging the system Mo...

Страница 10: ...2 Ceiling mounted unit a 4 6 13 4 4 6 180 4 8 14 6 4 8 196 5 0 15 8 5 0 213 1 842 5 2 17 1 1 842 5 2 230 1 843 3 64 5 4 18 5 1 843 28 9 5 4 248 2 0 3 95 5 6 19 9 2 0 34 0 5 6 267 2 2 4 34 5 8 21 3 2...

Страница 11: ...Take sufficient precautions in case of refrigerant leakage If refrigerant gas leaks ventilate the area immediately Possible risks Excessive refrigerant concentrations in a closed room can lead to oxy...

Страница 12: ...ant in liquid form Adding it in gas form may prevent normal operation CAUTION When the refrigerant charging procedure is done or when pausing close the valve of the refrigerant tank immediately If the...

Страница 13: ...G After finishing the electrical work confirm that each electrical component and terminal inside the electrical components box is connected securely Make sure all covers are closed before starting up...

Страница 14: ...io waves a distance of 1 meter may NOT be sufficient NOTICE ONLY applicable if the power supply is three phase and the compressor has an ON OFF starting method If there exists the possibility of rever...

Страница 15: ...ation 429 CAUTION Piping and joints of a split system shall be made with permanent joints when inside an occupied space except joints directly connecting the piping to the indoor units DANGER RISK OF...

Страница 16: ...Do NOT install a phase advancing capacitor because this unit is equipped with an inverter A phase advancing capacitor will reduce performance and may cause accidents WARNING Use an all pole disconnec...

Страница 17: ...t Prepare in advance the path along which you want to bring the unit to its final installation position When handling the unit take into account the following Fragile handle the unit with care Keep th...

Страница 18: ...nual c General safety precautions d Titanium apatite deodorising filter and the silver particle filter Ag ion filter e Indoor unit fixing screw M4 12L Refer to 9 3 To fix the unit on the mounting plat...

Страница 19: ...ection cable g Insulation tape 5 2 Operation range Use the system in the following temperature and humidity ranges for safe and effective operation Operation mode Operation range Cooling a b Outdoor t...

Страница 20: ...the piping on left side left back or left bottom 27 6 4 4 To check for water leaks 28 6 1 Preparing the installation site Choose an installation location with sufficient space to transport the unit in...

Страница 21: ...following places because it may shorten the life of the unit Where the voltage fluctuates a lot In vehicles or vessels Where acidic or alkaline vapour is present In places where a mineral oil mist spr...

Страница 22: ...Pull out the service cover horizontally away from the unit a b a Service cover screw b Service cover 6 2 3 To remove the front grille CAUTION Wear adequate personal protective equipment protective gl...

Страница 23: ...ctrical wiring box cover a a c b a 1 3 2 a Tab b Protruding part on the top of the cover c Screw 6 3 Mounting the indoor unit In this chapter 6 3 1 To install the mounting plate 23 6 3 2 To drill a wa...

Страница 24: ...Center of the unit 6 3 2 To drill a wall hole CAUTION For walls containing a metal frame or a metal board use a wall embedded pipe and wall cover in the feed through hole to prevent possible heat ele...

Страница 25: ...to remove the pipe port cover as this would damage the front grille 6 4 Connecting the drain piping In this chapter 6 4 1 General guidelines 25 6 4 2 To connect the piping on right side right back or...

Страница 26: ...socket nominal 13 mm a b c 18 a Drain hose supplied with the indoor unit b Drain socket with nominal 13 mm field supply c Ridgid polyvinyl chloride pipe field supply Condensation Take measures agains...

Страница 27: ...om the right side and install it on the left side 1 Remove the insulation fixing screw on the right side and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right s...

Страница 28: ...A Left side piping B Left back piping C Left bottom piping a Remove the pipe port cover here for left side piping b Remove the pipe port cover here for left bottom piping 6 4 4 To check for water lea...

Страница 29: ...d space except joints directly connecting the piping to the indoor units NOTICE The piping and other pressure containing parts shall be suitable for refrigerant Use phosphoric acid deoxidised seamless...

Страница 30: ...should be at least 20 mm to prevent condensation on the surface of the insulation 7 2 Connecting the refrigerant piping 7 2 1 About connecting the refrigerant piping Before connecting the refrigerant...

Страница 31: ...ls e g mineral oils and moisture from mixing into the system Install the piping so that the flare is NOT subjected to mechanical stress Do NOT leave pipes unattended at the site If the installation is...

Страница 32: ...as possible bending radius should be 30 40 mm or larger 7 2 5 To flare the pipe end CAUTION Incomplete flaring may cause refrigerant gas leakage Do NOT re use flares Use new flares to prevent refriger...

Страница 33: ...flare connections 2 Wrap the refrigerant piping connection using vinyl tape overlapping at least half the width of the tape with each turn Keep the slit of the heat insulation pipe cover up Avoid wrap...

Страница 34: ...e electrical wiring typically consists of the following stages 1 Making sure the power supply system complies with the electrical specifications of the units 2 Connecting the electrical wiring to the...

Страница 35: ...reaker with at least 3 mm between the contact point gaps that provides full disconnection under overvoltage category III WARNING If the supply cord is damaged it MUST be replaced by the manufacturer i...

Страница 36: ...Item Tightening torque N m M4 X1M 1 2 M4 earth The earth wire between the wire retainer and the terminal must be longer than the other wires 1 3 8 1 3 Specifications of standard wiring components Comp...

Страница 37: ...able c Wire guide 2 Pass the interconnection cable from the outdoor unit through the feed through wall hole through the back of the indoor unit and through the front side Note In case the interconnect...

Страница 38: ...s LAN adapter CANNOT be used together with other optional accessory 1 Remove the electrical wiring box cover see 6 2 4 To remove the electrical wiring box cover 423 2 Remove the wireless LAN adapter c...

Страница 39: ...nt piping and the electrical wiring are finished Wrap refrigerant piping interconnection cable and drain hose together using insulation tape Overlap at least half the width of the tape with each turn...

Страница 40: ...f the mounting plate Make sure that the wires do NOT get squeezed anywhere Note Take care that the interconnection cable does NOT get caught in the indoor unit 3 Press the bottom edge of the indoor un...

Страница 41: ...then mount the front panel 9 4 3 To close the service cover 1 Place the service cover to its original place on the unit 2 Install 1 screw back on the service cover 9 4 4 To re install the front panel...

Страница 42: ...rding to the definition of Directive 2014 53 EU and S I 2017 1206 Radio Equipment Regulations 2017 INFORMATION Install the wireless LAN adapter after finishing the indoor unit installation Refer to 10...

Страница 43: ...To connect the wireless LAN adapter with the unit 1 Remove the tape holding the connecting cord connector a a Tape 2 Cut the clip and remove the connector from the protection sleeve b a a Protection...

Страница 44: ...top of the lower case and press to close the box 7 Fix the upper adapter case with 2 screws accessory 2 10 2 2 To place the adapter into the unit 1 Place the wireless LAN adapter into the holder 2 Pre...

Страница 45: ...022 06 10 2 3 To check the functionality of the adapter 1 Turn on the power supply and check that the RUN lamp of the product blinks 10 3 To install the ONECTA app 1 Open Google Play for appliances us...

Страница 46: ...e careful NOT to damage any of the surrounding parts when cutting the address jumper 3 Turn the power supply on Result The flap of the indoor unit will open and close to set the reference position 4 P...

Страница 47: ...4L 2022 06 8 When the setting is complete Keep pressed for about 5 seconds Result The user interface will return to the previous screen INFORMATION In case you could NOT complete the setting in time t...

Страница 48: ...fore commissioning 1 After the installation of the unit check the items listed below 2 Close the unit 3 Power up the unit You read the complete installation instructions as described in the installer...

Страница 49: ...t to make sure that all functions and parts are working properly 1 In cooling mode select the lowest programmable temperature In heating mode select the highest programmable temperature Test run can b...

Страница 50: ...user Make sure that the user has the printed documentation and ask him her to keep it for future reference Inform the user that he can find the complete documentation at the URL mentioned earlier in t...

Страница 51: ...3 14L 2022 06 14 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MU...

Страница 52: ...parts and numbering refer to the wiring diagram on the unit Part numbering is by Arabic numbers in ascending order for each part and is represented in the overview below by in the part code Symbol Mea...

Страница 53: ...V L Pilot lamp light emitting diode HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic rela...

Страница 54: ...high S NPL Pressure sensor low S PH HPS Pressure switch high S PL Pressure switch low S T Thermostat S RH Humidity sensor S W SW Operation switch SA F1S Surge arrester SR WLU Signal receiver SS Selec...

Страница 55: ...lication explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instructions In...

Страница 56: ...4P518023 14L 2022 06 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: